评估多阶段AI驱动工作流对全科与专科医生临床诊断效能的影响。结果显示全科医生的癌症检出率与召回阳性预测值显著提高,达到与专科医生相当水平。

要点

  • 全科医生使用AI工作流后癌症检出率从3.76升至4.99/1000例,达到专科医生水平。
  • 全科医生召回阳性预测值提高15.09%,召回效率改善。
  • 专科医生加入AI工作流后癌症检出率与召回阳性预测值无显著变化。

核心结论

  • 多阶段AI驱动工作流显著提高全科医生的癌症检出率与召回阳性预测值,使其达到与专科医生相当水平。
  • 专科医生加入AI工作流后癌症检出率与召回阳性预测值未出现显著变化。

研究设计与样本

  • 纳入95名在两个研究期间均解读数字乳腺断层合成筛查的放射科医生,其中60名全科、35名专科。
  • 多阶段AI驱动工作流整合一个计算机辅助检测与诊断设备及一个独立的「Safeguard Review」环节,将AI识别为可疑但未召回的筛查转给额外专家复核。
  • 采用带广义估计方程的逻辑回归比较AI工作流引入前后的调整后癌症检出率、召回阳性预测值与召回率。

诊断标准与关键数值

  • 全科医生调整后癌症检出率从3.76/1000例(95% CI: 3.46, 4.08)升至4.99/1000例(95% CI: 4.51, 5.53;P < .001)。
  • 专科医生调整后癌症检出率从4.47/1000例升至4.76/1000例(P = .33)。
  • 全科医生使用AI后的癌症检出率与专科医生使用AI后相比无显著差异(P = .53)。
  • 全科医生召回阳性预测值从3.38%(95% CI: 3.03, 3.75)升至3.89%(95% CI: 3.39, 4.46),相对提高15.09%(P = .02)。
  • 全科医生召回率从9.06%相对增加14.79%至10.40%(P = .007),专科医生召回阳性预测值无变化(P = .86)。

临床应用与阅片要点

  • 全科医生可借助该多阶段AI工作流提升筛查乳腺癌检出率,缩小与专科医生的差距。
  • AI识别的可疑但未召回的筛查经额外专家复核,有助于减少漏诊。
  • 专科医生使用该AI工作流未见额外获益,可保持原有阅片流程。

局限性

  • 仅纳入在两个研究期间均解读且符合设备与年龄条件的放射科医生,可能存在选择偏倚。
  • 召回率升高伴随全科医生使用AI,需关注不必要召回增加的潜在负担。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Radiologist expertise plays a critical role in breast cancer screening outcomes; yet approximately 70% of screening mammography interpretations in the United States are performed by general radiologists (generalists) rather than breast imaging specialists (specialists). Purpose To evaluate the impact of a multistage artificial intelligence (AI)-driven workflow on the clinical performance of generalists and fellowship-trained specialists. Materials and Methods This prospective study included screening mammogram interpretations from radiologists across 109 U.S. imaging facilities performed between September 2021 and December 2022. Only radiologists who interpreted digital breast tomosynthesis screening examinations during both study periods were included, and only bilateral examinations from women aged 35 years or older were included. The multistage AI-driven workflow integrated a computer-aided detection and diagnosis device and a separate "Safeguard Review" that routes AI-identified suspicious screening mammogram examinations that were not recalled for additional expert review. Adjusted cancer detection rate (CDR), positive predictive value (PPV) of recalls, and recall rate (RR) were compared before and after introduction of the multistage AI-driven workflow using logistic regression with generalized estimating equations. Results A total of 95 radiologists (60 generalists with a median of 19 years of experience [IQR, 14-31 years; range, 3-50 years] and 35 specialists with a median of 11 years of experience [IQR, 6-21 years; range, 1-32 years]) interpreting 577 742 examinations were included. Adjusted results show that the CDR of generalists increased from 3.76 (95% CI: 3.46, 4.08) to 4.99 (95% CI: 4.51, 5.53; P < .001) cancers per 1000 examinations with the AI workflow. The CDR of specialists was similar before and after adding the AI workflow (from 4.47 to 4.76 per 1000 examinations, respectively; P = .33) and was similar to that of generalists with AI (P = .53). Among generalists, PPV of recalls increased by 15.09% (from 3.38% [95% CI: 3.03, 3.75] to 3.89% [95% CI: 3.39, 4.46]; P = .02), indicating more efficient cancer detection (more cancers detected per recall) despite a 14.79% relative increase in RR (from 9.06% to 10.40%, P = .007). Specialists showed no change in PPV of recalls with the AI workflow (P = .86). Conclusion A multistage AI-driven workflow was associated with substantially improved CDR and PPV of recalls for generalists, which were on par with those of specialists. © RSNA, 2026 Supplemental material is available for this article. See also the editorial by Schiaffino and Cozzi in this issue.