文献速递心血管MR

4D flow CMR早期检出高血压患者左室舒张功能障碍的可行性

Feasibility of early detection of left ventricular diastolic dysfunction in hypertensive patients using four-dimensional flow cardiac magnetic resonance.
PubMed 文献 · Eur J Radiol · 2026-07-16

通过4D flow CMR计算左室动能参数并与对照组及亚组比较,采用ROC评估诊断效能。结果显示KE E/A比值对LVDD的AUC为0.801,在非左室肥厚亚组为0.805,与E/e'的0.810相当。

要点

  • 高血压患者4D flow左室动能参数改变可比无肥厚时出现,提示用于早期发现
  • KE E/A比值检测LVDD效能与超声E/e'相当,适合作为补充评估指标
  • 非左室肥厚亚组中KE E/A比值AUC仍达0.805,有助于识别无LVH的早期舒张障碍

核心结论

  • 4D flow CMR衍生的KE E/A比值检测高血压患者早期左室舒张功能障碍的效能与E/e'相当
  • 即便在无左室肥厚的高血压患者中,KE E/A比值仍保持对早期LVDD的检测能力

研究设计与样本

  • 高血压患者根据超声多参数评估分为LVDD与非LVDD亚组,并进一步分为LVH与非LVH亚组
  • 4D flow CMR计算左室动能参数并按左室舒张末期容积校正,获得收缩期、舒张早期、舒张晚期KEiEDV、平面内KE百分比及峰值E波KE传播时间差

关键影像表现/征象

  • 与对照组相比,高血压患者E波KEiEDV和KE E/A比值降低,A波KEiEDV、平面内KE百分比及时间差增加(均P<0.01)
  • 非左室肥厚亚组表现出与整体高血压组相似的动能参数改变

诊断标准与关键数值

  • LVDD依据多参数超声心动图评估,纳入E/e'、E/A比值和左房内径
  • 检测LVDD时,KE E/A比值在全部高血压队列的AUC为0.801
  • KE E/A比值在非左室肥厚亚组的AUC为0.805
  • E/e'检测LVDD的AUC为0.810
  • 在所有评估的动能参数和常规CMR参数中,KE E/A比值对LVDD诊断准确性最高

临床应用与阅片要点

  • 4D flow CMR左室动能参数可用于高血压患者舒张功能的无创评估,尤其当超声显示不清或需要同时评估血流时
  • KE E/A比值可在无左室肥厚时提供早期舒张功能障碍提示,有助于更早识别亚临床改变
  • 报告时可关注E波与A波KEiEDV的相对关系及平面内KE和时间差的变化方向

局限性

  • 回顾性单中心设计

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To identify whether early left ventricle diastolic dysfunction(LVDD) in hypertension (HTN), with or without left ventricular hypertrophy (LVH), can be detected by four-dimensional flow cardiac magnetic resonance (4D flow CMR).

METHODS: Sixty-six HTN patients and thirty age-/gender matched healthy controls were retrospectively analyzed. The HTN patients were divided into the LVH and non-LVH subgroup, and were further divided into LVDD and non-LVDD subgroup according to a multiparametric echocardiographic assessment incorporating E/e', E/A ratio, and LA diameter(LAd). 4D flow-derived left ventricular (LV) kinetic energy (KE) parameters were calculated and indexed to LV end-diastolic volume (EDV), including KEiEDV during systole, early diastole, and late diastole, as well as in-plane KE(%) and the time difference (TD) of peak E-wave KE propagation. KE parameters were compared among healthy controls, HTN patients with LVDD, and HTN patients without LVDD, as well as between LVH and non-LVH subgroups. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of KE parameters for detecting LVDD.

RESULTS: HTN patients showed significantly altered KE patterns compared with controls, characterized by decreased E-wave KEiEDV and KE E/A ratio and increased A-wave KEiEDV, in-plane KE(%), and TD (all P < 0.01), with similar findings in the non-LVH subgroup. For LVDD detection, the KE E/A ratio demonstrated the best diagnostic accuracy among all evaluated KE and conventional CMR parameters, with an AUC of 0.801 in the overall HTN cohort and 0.805 in the non-LVH subgroup, comparable to E/e' (AUC = 0.810).

CONCLUSIONS: The KE E/A ratio derived from 4D flow CMR is comparable to E/e' for detecting early LVDD in HTN patients, and remains effective even in the absence of LVH.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Peng, Zhao, Wang, et al. Feasibility of early detection of left ventricular diastolic dysfunction in hypertensive patients using four-dimensional flow cardiac magnetic resonance. Eur J Radiol. 2026. PMID: 42476059. doi:10.1016/j.ejrad.2026.113084

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。