深度学习呼吸触发MRCP与传统呼吸触发及屏气压缩感知MRCP比较
回顾性纳入116例患者,比较基于深度学习的呼吸触发、传统呼吸触发和屏气压缩感知3D MRCP。结果显示DL序列有效呼吸周期较CON减少约68%,且DL与CON在定性图像评估中无显著差异。两种呼吸触发技术对外周肝内胆管与胰管段显示均优于BH-CS。
要点
- 评估外周肝内胆管与胰管段显示时,DL和CON优于BH-CS。
- DL呼吸触发MRCP图像质量与CON相当,并减少约68%有效呼吸周期。
- 阅片者间一致性κ为0.73–0.94。
核心结论
- DL呼吸触发3D MRCP较CON减少有效呼吸周期并提高采集效率。
- DL与CON在定性图像评估中无显著差异;两者外周肝内胆管与胰管段显示均优于BH-CS。
研究设计与样本
- 回顾性研究纳入116例患者,均接受DL、CON和BH-CS MRCP检查。
- 定量分析胆总管相对对比度。
- 两名阅片者定性评估10段胰胆管显示、背景抑制、运动伪影、整体图像质量及胰腺囊性病灶显示度。
- 呼吸触发序列采集效率以有效呼吸周期数比较。
关键影像表现/征象
- DL和CON对外周肝内胆管及胰管段的显示评分均显著高于BH-CS(均p<0.01)。
- 胆总管与肝总管的显示在三序列间无显著差异。
- 阅片者1未发现病灶显示度存在序列间差异;阅片者2显示BH-CS病灶显示度高于DL(adjusted P=0.01)。
诊断标准与关键数值
- DL的胆总管相对对比度为0.87±0.07,BH-CS为0.91±0.08,CON为0.83±0.08;DL和BH-CS均显著高于CON(p<0.01)。
- 两位阅片者整体图像质量评分DL和CON均值3.4–3.5,BH-CS为2.8,DL和CON显著高于BH-CS。
- ≥1 cm胰腺囊性病灶在14.7%的检查中检出,各序列检出率无显著差异。
- DL所需有效呼吸周期为19个,CON为60个,减少约68%。
- 阅片者间一致性κ为0.73–0.94。
临床应用与阅片要点
- DL呼吸触发MRCP较CON减少约68%有效呼吸周期,可用于提高呼吸触发序列采集效率。
- 报告外周肝内胆管与胰管段病变时,DL或传统呼吸触发MRCP显示优于BH-CS。
- BH-CS在胰腺囊性病灶显示度方面结果存在阅片者间差异,阅片者2显示其高于DL。
局限性
- 回顾性研究设计存在选择偏倚可能。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate whether deep learning-based respiratory-triggered (DL) 3D magnetic resonance cholangiopancreatography (MRCP) improves acquisition efficiency while providing similar qualitative image assessment results to conventional respiratory-triggered (CON) and breath-hold compressed sensing (BH-CS) MRCP.
METHODS: This retrospective study included 116 patients who underwent DL, CON, and BH-CS MRCP. Relative contrast (RC) of the common bile duct (CBD) was quantitatively analyzed. Two reviewers qualitatively assessed ductal visibility (10 segments), background suppression, motion artifacts, overall image quality, and conspicuity of pancreatic cystic lesions. Acquisition efficiency of respiratory-triggered sequences was compared based on the number of effective respiratory cycles.
RESULTS: Interobserver agreement was substantial to almost perfect (κ = 0.73-0.94). RC was significantly higher with DL (0.87 ± 0.07) and BH-CS (0.91 ± 0.08) compared with CON (0.83 ± 0.08; p < 0.01). Visibility of the CBD and common hepatic duct did not differ significantly among sequences, whereas DL and CON showed significantly higher visibility of peripheral intrahepatic and pancreatic duct segments than BH-CS (all p < 0.01). Overall image quality scores were significantly higher for DL and CON than for BH-CS for both readers (mean scores, 3.4-3.5 vs. 2.8). Pancreatic cystic lesions ≥ 1 cm were detected in 14.7% of examinations with no significant difference in detection rates among sequences. For lesion conspicuity, reader 1 found no significant between-sequence differences, whereas reader 2 reported higher conspicuity scores for BH-CS than for DL (adjusted P = 0.01). DL required fewer effective respiratory cycles than CON (19 vs. 60 cycles), corresponding to an approximately 68% reduction in respiratory-triggered acquisition burden.
CONCLUSION: DL-based respiratory-triggered 3D MRCP demonstrated improved acquisition efficiency with fewer effective respiratory cycles than CON. No significant differences were detected between DL and CON in qualitative image assessment, while both respiratory-triggered techniques showed higher peripheral duct visibility than BH-CS.
引用
- Ryu, Lee, Park, et al. Deep learning-based respiratory-triggered magnetic resonance cholangiopancreatography: comparison with conventional respiratory-triggered and breath-hold magnetic resonance cholangiopancreatography. Abdom Radiol (NY). 2026. PMID: 42440114. doi:10.1007/s00261-026-05670-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。