文献速递妇产影像US

术前超声滑动膀胱征预测子宫切除中膀胱子宫粘连

Predicting bladder-to-uterine adhesions in patients undergoing hysterectomy using sliding-bladder sign technique with preoperative ultrasound: a diagnostic accuracy study.
PubMed 文献 · Ultrasound Obstet Gynecol · 2026-07-10

本研究为前瞻性诊断准确性研究,纳入128例拟行腹腔镜子宫切除术的良性妇科疾病患者。所有患者术前经阴道超声评估滑动膀胱征,以术中所见膀胱子宫粘连为参考标准。结果显示滑动膀胱征的准确度为89.1%,特异度达96.7%,提示该征象可作为术前预测前腔室粘连的无创工具。

要点

  • 滑动膀胱征阴性(无滑动)提示膀胱子宫粘连可能性大,阳性预测值89.3%。
  • 滑动膀胱征阳性可较可靠排除粘连,阴性预测值89.0%。
  • 该征象可作为术前经阴道超声的常规评估项目,指导围术期准备。

核心结论

  • 滑动膀胱征经阴道超声评估是预测膀胱子宫粘连的无创工具,当膀胱滑动消失时可靠性较高。
  • 将该征象纳入术前超声检查有助于前腔室粘连的解剖预判与围术期准备。

研究设计与样本

  • 前瞻性诊断准确性研究,纳入加拿大Hamilton Health Sciences中心128例计划行腹腔镜子宫切除术的良性妇科疾病患者。
  • 参考标准为子宫切除术中确认膀胱子宫粘连,术者与超声评估者互盲。

关键影像表现/征象

  • 滑动膀胱征通过术前经阴道超声动态评估膀胱与子宫之间的相对滑动情况。

诊断标准与关键数值

  • 滑动膀胱征诊断膀胱子宫粘连的敏感度为69.4%(95% CI, 51.9-83.6%)。
  • 特异度为96.7%(95% CI, 90.1-99.3%)。
  • 准确度为89.1%(95% CI, 82.3-93.9%)。
  • 阳性预测值为89.3%(95% CI, 72.8-96.3%),阴性预测值为89.0%(95% CI, 83.2-93.0%)。
  • 阳性似然比为21.3(95% CI, 6.8-66.2),阴性似然比为0.3(95% CI, 0.2-0.5)。

临床应用与阅片要点

  • 滑动膀胱征消失时应高度怀疑膀胱子宫粘连,建议在报告中提示前腔室粘连可能。
  • 该征象特异度高、阳性预测值较高,适合用于术前排除性或确认性筛查。
  • 敏感度中等,滑动征存在时仍有少部分患者存在粘连,需结合其他间接征象。
  • 该评估简便无创,可常规加入术前经阴道超声检查流程。

局限性

  • 该研究为单中心设计,结果为加拿大Hamilton Health Sciences中心数据,外推至其他人群需谨慎。
  • 滑动膀胱征的敏感度有限,假阴性病例可能被遗漏。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed to determine the accuracy of the sliding-bladder sign assessed using preoperative transvaginal ultrasound (TVS) for identifying the presence of bladder-to-uterine (BTU) adhesions in patients undergoing hysterectomy.

METHODS: This was a prospective diagnostic test-accuracy study conducted at Hamilton Health Sciences, Hamilton, ON, Canada. Patients scheduled for a planned laparascopic hysterectomy for a benign gynecological condition between October 2021 and December 2024 were included and all underwent preoperative TVS examination that included assessment of the sliding-bladder sign. The presence of BTU adhesions was assessed using TVS (index test) and confirmed at hysterectomy (reference standard) by independent assessors who were blinded to the outcome of the other test. The accuracy, specificity, sensitivity, positive and negative predictive values and positive and negative likelihood ratios of the sliding-bladder sign were calculated.

RESULTS: Of 128 included women, 28.1% had BTU adhesions confirmed at hysterectomy. The sliding-bladder sign on preoperative TVS demonstrated an accuracy of 89.1% (95% CI, 82.3-93.9%), with a sensitivity of 69.4% (95% CI, 51.9-83.6%) and a specificity of 96.7% (95% CI, 90.1-99.3%). The positive predictive value was 89.3% (95% CI, 72.8-96.3%), while the negative predictive value was 89.0% (95% CI, 83.2-93.0%). The positive likelihood ratio was 21.3 (95% CI, 6.8-66.2) and the negative likelihood ratio was 0.3 (95% CI, 0.2-0.5).

CONCLUSIONS: The sliding-bladder sign assessed using TVS is a non-invasive tool for predicting the presence of BTU adhesions that is reliable when bladder sliding is absent. Incorporating this assessment into preoperative ultrasound examinations may support anatomical anticipation of anterior-compartment adhesions and perioperative preparedness as part of a comprehensive evaluation. © 2026 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. van Keizerswaard, Freger, Mick, et al. Predicting bladder-to-uterine adhesions in patients undergoing hysterectomy using sliding-bladder sign technique with preoperative ultrasound: a diagnostic accuracy study. Ultrasound Obstet Gynecol. 2026. PMID: 42427219. doi:10.1002/uog.70281

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。