跨CT设备主动脉瓣钙化积分对超声分级不一致重度主动脉瓣狭窄的再分类

Vendor-independent Aortic Valve Calcium Scoring in Patients with Discordant Echocardiographic Criteria of Severe Aortic Stenosis.
PubMed 文献 · Radiol Cardiothorac Imaging · 2026-01-01

本研究先在体模中于7种CT系统及电子束CT参考系统上建立并验证与设备无关的Agatston积分(vnAS),再回顾性纳入8个国际中心831例患者。以超声为标准,183例(22.0%)存在重度主动脉瓣狭窄分级不一致,应用vnAS后8.5%的女性和17.8%的男性被再分类为重度主动脉瓣狭窄。该工具可减少CT设备间差异对主动脉瓣钙化定量和狭窄分级的影响。

要点

  • vnAS可跨CT设备标准化主动脉瓣钙化定量,减少设备间差异。
  • 超声分级不一致的重度主动脉瓣狭窄患者中,vnAS高于传统主动脉瓣钙化积分。
  • 应用vnAS后,相当比例超声不一致患者被再分类为重度主动脉瓣狭窄。

核心结论

  • vnAS在不同CT系统间与参考系统Agatston积分呈强相关(R2>0.932),并在多中心患者样本中成功验证。
  • 应用vnAS可使8.5%的女性和17.8%的男性超声分级不一致患者被再分类为重度主动脉瓣狭窄。

研究设计与样本

  • 体模实验使用7种不同CT系统及电子束CT参考系统扫描不同钙化程度的拟人体模以确定vnAS。
  • vnAS通过回归模型计算,模型性能以决定系数和方差分析评估。
  • 患者验证为回顾性研究,样本来自8个国际中心,共831例患者。
  • 831例患者平均年龄77岁±10,其中351例(42.2%)为女性。
  • 重度主动脉瓣狭窄阈值为女性1274 AU、男性2065 AU。

关键影像表现/征象

  • 所有CT系统的Agatston积分与参考系统的Agatston积分均呈强相关(R2>0.932)。
  • 831例患者中183例(22.0%)超声结果提示重度主动脉瓣狭窄分级不一致。
  • 超声不一致女性中vnAS中位数1693 AU(IQR 908-2513 AU),高于传统主动脉瓣钙化积分1181 AU(IQR 726-1964 AU),P<.001。
  • 超声不一致男性中vnAS中位数2658 AU(IQR 1894-3822 AU),高于传统主动脉瓣钙化积分2056 AU(IQR 1408-3056 AU),P<.001。

诊断标准与关键数值

  • 重度主动脉瓣狭窄钙化积分的vnAS阈值为女性1274 AU、男性2065 AU。
  • 体模实验中各CT系统与参考系统Agatston积分的决定系数R2均大于0.932。
  • 以超声心动图结果为标准,831例中183例(22.0%)存在重度主动脉瓣狭窄分级不一致。

临床应用与阅片要点

  • 在日常阅片中,对超声分级不一致的疑似重度主动脉瓣狭窄患者,可应用vnAS重新评估主动脉瓣钙化负荷。
  • 采用vnAS可减少因CT设备不同导致的钙化积分差异,使不同医院的主动脉瓣钙化定量更具可比性。
  • 注意传统主动脉瓣钙化积分可能系统性低估超声不一致患者的钙化负荷,尤其需要关注接近阈值的病例。

局限性

  • 患者验证部分为回顾性研究设计。
  • 患者样本来自8个国际中心,可能存在中心间纳入标准或扫描方案的异质性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To apply a vendor-neutral Agatston score (vnAS) for aortic valve calcification across multiple CT systems and to aortic stenosis severity classification. Materials and Methods Anthropomorphic phantoms with varying degrees of calcification were scanned using seven different CT systems and a reference electron-beam CT system to determine the vnAS. The vnAS was calculated using a regression model, whose performance was evaluated by both the coefficient of determination and analysis of variance. The vnAS was subsequently validated on a retrospective patient sample from eight international centers. Thresholds of severe aortic valve stenosis were defined as 1274 and 2065 AU for women and men, respectively. Results The Agatston scores from all CT systems were strongly correlated with that of the reference system (R2 > 0.932). On the basis of their echocardiographic findings, 183 of 831 (22.0%) patients (mean age ± SD, 77 years ± 10; 351 of 831 [42.2%] women) had discordant echocardiographic aortic valve stenosis findings. Among women with discordant results, the vnAS was higher than the traditional aortic valve calcium score (median, 1693 AU [IQR, 908-2513 AU] vs 1181 AU [IQR, 726-1964 AU], respectively; P < .001). Similar findings were observed for men (median, 2658 AU [IQR, 1894-3822 AU] vs 2056 AU [IQR, 1408-3056 AU], respectively; P < .001). Using the vnAS, 8.5% of women and 17.8% of men with discordant echocardiographic findings were reclassified into the severe aortic stenosis group. Conclusion A previously developed calibration tool, the vnAS, was validated and reclassified patients with discordant echocardiographic findings into the severe aortic stenosis group. Keywords: CT, Echocardiography, Percutaneous, Cardiac, Valves, Calcifications/Calculi, Technology Assessment, Vendor-neutral Agatston Score, Aortic Stenosis, Aortic Valve Calcification, Phantoms Supplemental material is available for this article. © RSNA, 2026 See also commentary by Jaltotage and Leipsic in this issue.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Dobrolińska, van der Werf, Greuter, et al. Vendor-independent Aortic Valve Calcium Scoring in Patients with Discordant Echocardiographic Criteria of Severe Aortic Stenosis. Radiol Cardiothorac Imaging. 2026. PMID: 42423464. doi:10.1148/ryct.250480

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。