深度学习重建使1.5T MRI血管壁成像可与3T互换
前瞻性纳入50例患者,比较1.5T联合深度学习重建的T1 3D SPACE与标准3T T1 3D SPACE。3位资深放射科医师评估病理性血管壁强化。结果显示两种序列具有互换性,1.5T图像质量均可诊断,但3T图像质量与诊断信心更高。
要点
- 1.5T联合深度学习重建的血管壁成像与3T序列在判断病理性血管壁强化方面可互换
- 1.5T图像质量所有病例均达诊断水平,但3T图像质量更优
- 诊断信心3T略优于1.5T,差异有统计学意义
核心结论
- 深度学习重建使1.5T MRI血管壁成像成为可能,该新序列与3T标准序列在检测病理性血管壁强化方面具有互换性
- 该进展可显著提高血管壁成像在临床常规中的可及性
研究设计与样本
- 前瞻性研究,共纳入50例受试者,平均年龄42.6±21.2岁,26例男性
- 采用1.5T联合深度学习重建的T1加权可变翻转角3D SPACE序列与3T标准T1 3D SPACE序列对照
- 由3位资深放射科医师独立评估病理性血管壁强化情况、图像质量及诊断信心
关键影像表现/征象
- 1.5T联合深度学习重建序列在病理性血管壁强化检出方面与3T标准序列具有互换性,IEI=0.008
- 1.5T图像质量所有病例均达诊断水平,3T图像质量评分更高(P<0.001)
- 诊断信心3T略微但显著高于1.5T(P<0.001)
诊断标准与关键数值
- 病理性血管壁强化判断的观察者间一致性:1.5T序列Fleiss κ=0.72(95% CI 0.62-0.81),3T序列Fleiss κ=0.78(95% CI 0.69-0.88)
- 两种场强序列互换性分析IEI=0.008,提示具有互换性
- 图像质量与诊断信心采用5分Likert量表评估,3T均优于1.5T(P<0.001)
临床应用与阅片要点
- 深度学习重建可支持1.5T设备开展颅内血管壁成像,适用于常规临床应用
- 3T血管壁成像图像质量与诊断信心仍优于1.5T,设备条件允许时优先选择3T
- 1.5T血管壁成像可作为3T不可及时的有效替代方案,不影响病理性强化的定性判断
局限性
- 原文未明确报告本研究为单中心或样本量相关局限
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Vessel wall magnetic resonance imaging is important in the diagnosis of intracranial vascular diseases. Until now, adequate clinical implementation has required the use of 3 T scanners, which limits wider availability. This study aims to evaluate the interchangeability of a 3D turbo spin echo sequence with variable flip angle MRI sequence (T1 3D Sampling Perfection with Application optimized Contrast using different flip angle Evolution, SPACE) with deep learning image reconstruction for a 1.5 T scanner, with an established sequence (T1 3D SPACE) for a 3 T scanner. In addition, image quality parameters and diagnostic confidence are to be compared.
MATERIALS AND METHODS: Patients were prospectively examined using a T1-weighted turbo spin echo with variable flip angle at 3 T and a similar newly developed sequence with deep learning-based image reconstruction at 1.5 T. The images were read by 3 experienced radiologists regarding the presence of pathologic enhancement of the vessel wall for the interchangeability analysis. Image quality and diagnostic confidence were evaluated using 5-point Likert scales. Interreader and intrareader reliability were calculated for all parameters.
RESULTS: A total of 50 participants (42.6 ± 21.2 y, 26 males) were included. Regarding the presence of pathologic vessel wall enhancement, there was a high interreader agreement [Fleiss kappa = 0.72 (95% CI: 0.62; 0.81) for 1.5T, 0.78 (0.69; 0.88) for 3 T]. The sequences at 1.5 T and 3 T were interchangeable (IEI = 0.008). Image quality at 1.5 T was diagnostic in all cases, but rated superior at 3 T (P < 0.001). Diagnostic confidence was also slightly but significantly higher at 3 T (P < 0.001).
CONCLUSIONS: The utilization of deep learning reconstruction enables vessel wall imaging in 1.5 T MRI. This new MRI sequence was interchangeable with established sequences at 3 T for the detection of pathologic vessel wall enhancement. This development could significantly improve the availability of vessel wall imaging in the clinical routine.
引用
- Michael, Almansour, Paul, et al. Vessel Wall Imaging in 1.5 T MRI Using Deep Learning Reconstruction: Prospective Evaluation of Interchangeability With Standard 3 T MRI. Invest Radiol. 2026. PMID: 42403272. doi:10.1097/RLI.0000000000001290
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。