常规序列半自动MRI乳腺密度测量与乳腺X线对比
本研究为单中心回顾性研究,纳入113例同时接受乳腺MRI与乳腺X线检查的女性,评估基于常规MRI序列的半自动乳腺密度测量流程。结果显示MRI密度与乳腺X线密度强相关(r=0.781),MRI值平均低27.7%,检测高密度乳腺的AUC为0.869,与乳腺X线的0.799无显著差异。
要点
- MRI测得乳腺密度值平均比乳腺X线低27.7%,报告对比时需注意系统差异
- MRI检测高密度乳腺的AUC达0.869,与乳腺X线(0.799)表现相当
- 半自动分割需手动校正,临床推广前仍需流程标准化
核心结论
- 基于常规MRI序列的半自动乳腺密度测量可实现无电离辐射的乳腺组成定量评估
- MRI密度测量的分类性能与乳腺X线评估相当,但进一步验证和流程标准化后方可广泛临床应用
研究设计与样本
- 单中心回顾性研究,纳入113例女性,平均年龄60.8±13.6岁
- 所有受试者均接受乳腺MRI和乳腺X线检查,评估对侧正常乳腺
- MRI采用3.0T设备,序列为3D T1加权梯度回波序列
- 乳腺和纤维腺体组织采用深度学习辅助自动分割并进行手动校正
- 统计分析包括相关分析、Bland-Altman分析和ROC分析
诊断标准与关键数值
- MRI乳腺密度与乳腺X线密度相关系数r=0.781,P<0.001
- MRI测得的密度值平均比乳腺X线低27.7%
- 检测高密度乳腺时MRI的ROC曲线下面积为0.869,乳腺X线为0.799,P=0.085
临床应用与阅片要点
- 常规3D T1梯度回波序列即可用于乳腺密度半自动定量,无需专用序列或特定厂商软件
- MRI和乳腺X线密度值不可直接互换,阅片比较时需考虑系统性的数值差异
- MRI密度评估可用于避免乳腺X线检查的电离辐射暴露
局限性
- 单中心回顾性研究设计
- 半自动分割需手动校正,流程尚未标准化
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: High breast density increases breast cancer risk and decreases mammographic sensitivity, yet prior magnetic resonance imaging (MRI)-based density assessments have relied on specialized sequences or vendor-dependent software. This study aimed to evaluate a semiautomated workflow for MRI-based breast density measurement using routinely acquired MRI sequences and compare its diagnostic performance and concordance with visual and software-based mammographic classifications.
MATERIALS AND METHODS: In this single-center retrospective study, we analyzed 113 women (mean age: 60.8 ± 13.6 years) who underwent both breast MRI and mammography. The contralateral, normal breast was evaluated. MRI was performed using a 3.0-T scanner with a 3D T1-weighted gradient-echo sequence. Breast and fibroglandular tissues were segmented using a deep learning-assisted automated method with manual correction. Statistical analyses included correlation analysis, Bland-Altman analysis, and receiver operating characteristic (ROC) analysis.
RESULTS: MRI-based breast density showed a strong correlation with mammographic density (r = 0.781, P < 0.001), although MRI values were on average 27.7% lower. The area under the ROC curve for detecting high-density breasts was 0.869 for MRI and 0.799 for mammography (P = 0.085).
CONCLUSIONS: Semiautomated MRI-based breast density assessment using routine MRI sequences allowed for quantitative evaluation of breast composition without using ionizing radiation. MRI-based density measurements exhibited classification performance comparable to mammographic assessment. These findings support the potential utility of MRI for quantitative breast density evaluation, although further validation and workflow standardization are required before broader clinical application.
引用
- Takatsu, Shimizu, Nakamura, et al. Semiautomated magnetic resonance imaging-based breast density measurement from routine sequences: comparison with mammography. Clin Radiol. 2026. PMID: 42401077. doi:10.1016/j.crad.2026.107405
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。