文献速递神经外周血管MRCT

高分辨MR血管壁成像鉴别斑块与缓慢血流伪影

Discrimination of plaque from sluggish-flow-related hyperintense artifact on high-resolution magnetic resonance vessel wall imaging.
PubMed 文献 · Eur J Radiol · 2026-07-01

结果显示缓慢血流伪影节段更长、强化率更高,且均表现为中央强化;中央强化模式鉴别斑块与伪影的准确率为0.84、敏感度100%、特异度69%。

要点

  • 缓慢血流伪影均表现为中央强化,该征象对鉴别伪影敏感度达100%。
  • 伪影强化节段更长、强化率更高、平扫SI标准差更低、增强后平均SI更高。
  • 后部强化位置与增强后SI参数可作为独立鉴别指标,阅片需结合管腔标准化评估。

核心结论

  • 强化模式、分布位置及定量信号强度参数有助于识别大脑中动脉重度狭窄或闭塞患者的缓慢血流相关伪影。

研究设计与样本

  • 所有患者均接受高分辨磁共振血管壁成像与CTA检查,以CTA作为参照标准分析HR-VWI特征。
  • 研究数据来自2020年1月至2025年6月间的影像资料回顾。

关键影像表现/征象

  • 与斑块相比,缓慢血流相关高信号累及节段更长,强化率更高。
  • 缓慢血流相关高信号平扫信号强度标准差较低,增强后平均信号强度较高。
  • 所有缓慢血流相关高信号均表现为中央强化。
  • 后部强化位置是斑块与伪影鉴别的独立相关特征。
  • 增强后信号强度标准差较低提示缓慢血流伪影。

诊断标准与关键数值

  • 中央强化模式鉴别斑块与缓慢血流相关高信号的准确率为0.84,敏感度为100%,特异度为69%。
  • 后部强化位置的比值比为16.62,95%置信区间为3.40-81.17,P<0.001。
  • 增强后平均信号强度的比值比为1.33,95%置信区间为1.05-1.67,P=0.016。
  • 增强后信号强度标准差的比值比为0.05,95%置信区间为0.004-0.68,P=0.024。

临床应用与阅片要点

  • 阅片时若高信号表现为中央强化且累及节段较长,应优先考虑缓慢血流伪影可能。
  • 增强后信号强度标准差较低及平均信号强度较高有助于与斑块相鉴别。
  • 后部强化位置是独立鉴别因素,应纳入日常报告描述与判读。
  • 准确判读仍有赖于对管腔进行标准化评估,不能仅凭强化特征单独下结论。

局限性

  • 回顾性研究设计本身存在选择偏倚可能。
  • 样本量有限,仅涉及大脑中动脉重度狭窄或闭塞患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The degree of plaque enhancement is critical for estimating the risk of incident and recurrent ischemic events in intracranial atherosclerotic stenosis. Hyperintensity caused by regional slow flow may confound plaque assessment. This study aimed to investigate methods for differentiating plaque from sluggish-flow-related hyperintense artifacts on high-resolution magnetic resonance vessel wall imaging (HR-VWI).

METHODS: Imaging data from January 2020 to June 2025 were retrospectively reviewed for patients with intracranial atherosclerotic stenosis who underwent both HR-VWI and computed tomography angiography (CTA). By comparison with CTA, features of plaque and adjacent sluggish-flow-related hyperintense artifacts on HR-VWI were analyzed.

RESULTS: Fifty-five patients (mean age 54.9 ± 9.35 years; 37 male and 18 female) with severe atherosclerotic stenosis or occlusion of the middle cerebral artery (MCA) were evaluated. Compared with plaque, slow-flow-related hyperintensity involved longer segments, showed a higher enhancement ratio, a lower standard deviation of signal intensity (SI) on pre-contrast images, and a higher mean post-contrast SI (all P < 0.05). All sluggish-flow-related hyperintensities exhibited central enhancement. The central enhancement pattern achieved an accuracy of 0.84, a sensitivity of 100%, and a specificity of 69% for discriminating plaque from sluggish-flow-related hyperintensities. Multivariable conditional logistic regression identified posterior enhancement location (OR, 16.62; 95% CI, 3.40-81.17; P < 0.001), post-contrast mean SI (odds ratio [OR], 1.33; 95% CI, 1.05-1.67; P = 0.016), and post-contrast SI standard deviation (OR, 0.05; 95% CI, 0.004-0.68; P = 0.024) as independent discriminators.

CONCLUSION: Enhancement pattern, distribution location, and quantitative signal intensity parameters are useful clues for identifying sluggish-flow-related artifacts in patients with severe MCA stenosis or occlusion. Accurate interpretation still hinges on a standardized evaluation of the lumen.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ouyang, Wu, Liu, et al. Discrimination of plaque from sluggish-flow-related hyperintense artifact on high-resolution magnetic resonance vessel wall imaging. Eur J Radiol. 2026. PMID: 42401076. doi:10.1016/j.ejrad.2026.113049

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。