文献速递泌尿生殖技术与安全US

微血流成像与超声黏弹性成像监测移植肾功能的比较

Comparative Study of Microvascular Flow and Viscoelasticity Imaging in Monitoring Renal Allograft Function.
PubMed 文献 · J Ultrasound Med · 2026-07-02

对61例肾移植受者(37例稳定、24例不稳定)行常规超声、MVFI和UVI,比较定量参数差异及其与eGFR、血肌酐的相关性,并用ROC评估诊断效能。结果显示皮质彩色像素百分比诊断准确性最高,且两种技术重复性均较好。

要点

  • 皮质彩色像素百分比与eGFR相关性较强,可用于日常评估移植肾灌注状态
  • MVFI区分移植肾稳定与不稳定的诊断准确性高于黏弹性成像
  • 黏弹性成像可提供补充性微结构信息,两者结合或有助于活检决策

核心结论

  • MVFI对区分稳定与不稳定移植肾具有较高诊断准确性,皮质彩色像素百分比的AUC为0.95,优于UVI参数。
  • UVI可提供补充性微结构信息,MVFI与UVI联合可能提高无创监测并优化肾移植受者的活检决策。

研究设计与样本

  • 研究纳入61例肾移植受者,其中37例稳定、24例不稳定,所有受试者接受常规超声、MVFI和UVI检查。
  • 定量参数包括全肾彩色像素百分比、皮质彩色像素百分比以及弹性、黏性和频散等黏弹性指标。
  • 采用适当统计学检验比较组间差异,评估参数与eGFR和血肌酐的相关性,并用ROC评价诊断效能。

诊断标准与关键数值

  • 皮质彩色像素百分比区分稳定与不稳定移植肾的AUC为0.95。
  • 其他黏弹性指标与eGFR和血肌酐的相关性较弱。
  • 所有参数的观察者内和观察者间一致性均较好(ICC>0.87)。

临床应用与阅片要点

  • 皮质彩色像素百分比可作为移植肾灌注评估的重要定量指标,建议在报告中记录该参数。
  • MVFI参数较UVI参数对区分移植肾稳定性更具优势,可用于协助早期识别不稳定移植肾。
  • UVI虽诊断准确性较低,但可反映微结构改变,必要时可与MVFI联合应用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to compare the efficacy of microvascular flow imaging (MVFI) and ultrasound viscoelasticity imaging (UVI) in assessing renal allograft stability, and to evaluate their potential as noninvasive diagnostic tools for early dysfunction detection and biopsy guidance.

METHODS: A total of 61 renal transplant recipients (37 stable, 24 unstable) were ultimately included. All participants underwent conventional ultrasonography, MVFI, and UVI. Quantitative parameters included entire color pixel percentage (eCPP), cortical color pixel percentage (cCPP), and viscoelastic metrics (elasticity, viscosity, and dispersion). Group differences were assessed using appropriate statistical tests; correlations with estimated glomerular filtration rate (eGFR) and serum creatinine were evaluated; and receiver operating characteristic (ROC) curves were generated to assess diagnostic performance. Intra- and inter-observer consistency was calculated to ensure measurement reliability.

RESULTS: Significant differences in color pixel percentage and multiple cortical viscoelastic parameters (eg, mean elasticity and viscosity) were observed between stable and unstable groups (p < .05). cCPP correlated strongly with eGFR (r = 0.715, p < .001) and serum creatinine (r = -0.731, p < .001), whereas other viscoelastic metrics showed weaker correlations. ROC analysis revealed that cCPP had superior diagnostic accuracy compared to the combined viscoelastic model. Both modalities exhibited excellent reproducibility (ICC >0.87 for all parameters).

CONCLUSION: MVFI provides high diagnostic accuracy for distinguishing stable and unstable renal allografts (cCPP AUC = 0.95), outperforming UVI parameters. UVI provides complementary microstructural information, and combining MVFI and UVI may enhance noninvasive monitoring and optimize biopsy decision-making in renal transplant recipients.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Li, Li, Liu, et al. Comparative Study of Microvascular Flow and Viscoelasticity Imaging in Monitoring Renal Allograft Function. J Ultrasound Med. 2026. PMID: 42389817. doi:10.1002/jum.70356

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。