指南与共识骨肌技术与安全CT

小鼠骨软骨单元micro-CT分析综述及软骨下骨标准化评估建议

Micro-CT-based analysis of the murine osteochondral unit: a review and recommendations for standardized subchondral bone assessment.
指南 / 共识 · JBMR Plus · 2026-06-14

本综述回顾小鼠关节micro-CT研究中的感兴趣区选择方法、常用参数,并基于长骨骨微结构指南提出骨软骨单元定量分析扩展建议。因缺乏专用指南,现有感兴趣区差异很大,且台式micro-CT难以区分软骨下骨板与钙化软骨。作者建议采用从关节面到生长板全部矿化组织的标准化感兴趣区,并推荐使用体积与厚度等稳健指标报告数据。

要点

  • 软骨下骨板与钙化软骨在台式micro-CT常无法区分,应按「软骨下矿化板」命名报告
  • 感兴趣区建议覆盖关节面至生长板全部矿化组织,以提高研究可比性
  • 报告时优先采用体积、厚度等稳健指标,孔隙率、矿物密度可酌情补充

核心结论

  • 建议为小鼠骨软骨单元micro-CT分析建立标准化感兴趣区,即包含从关节面到生长板的所有矿化组织
  • 由于台式micro-CT空间分辨率不足以区分软骨下骨板与钙化软骨,两者应作为一个整体测量并使用「软骨下矿化板」命名
  • 应继续使用软骨下骨板厚度和体积等常用指标,并优先报告稳健且易实施的参数

研究设计与样本

  • 综述聚焦小鼠研究,检查已报告的感兴趣区选择方法、常用评估参数,并提出扩展长骨骨微结构指南的建议

诊断标准与关键数值

  • 推荐感兴趣区包括从关节面到生长板的所有矿化组织
  • 鉴于软骨下骨板与软骨下骨小梁结构差异,建议采用一致的方法定义其边界
  • 推荐报告体积与厚度等稳健且易实施的指标,孔隙率、矿物密度等参数可酌情纳入
  • 当软骨下骨板与钙化软骨无法区分时,推荐使用「软骨下矿化板」命名

临床应用与阅片要点

  • 在报告鼠关节micro-CT结果时,避免声称单独测量了软骨下骨板,除非影像分辨率足以排除钙化软骨
  • 选择感兴趣区时需考虑品系、性别、年龄和疾病阶段造成的解剖差异

局限性

  • 台式microCT空间分辨率不足以区分软骨下骨板与钙化软骨
  • 小鼠骨软骨单元分析缺乏专用指南,导致已报告的感兴趣区选择差异很大

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Micro-CT enables high-resolution, 3D, and non-destructive visualization of bone microarchitecture in small preclinical animal models. It is widely applied to assess mineralized tissues in joints, making it a valuable tool for monitoring disease progression. Murine models are particularly prevalent in joint research due to their cost-effectiveness and disease tunability. Established guidelines for murine bone microstructure assessment provide a standardized framework for morphometric analysis and facilitate cross-study comparisons. However, these recommendations were developed for trabecular and cortical bone in long bones, and may not fully address the unique characteristics of mineralized tissues within joints. This review focuses on murine studies, and aims to: (1) examine reported methodologies for volume of interest selection; (2) outline commonly evaluated parameters; and (3) propose adaptations to expand existing guidelines for quantitative analysis of the osteochondral unit. In the absence of specific guidelines for osteochondral unit analysis, reported volumes of interest vary considerably and are influenced by anatomical differences across strains, sexes, ages, and disease stages. Many studies target the subchondral bone plate (SBP); however, the spatial resolution of desktop microCT is insufficient to distinguish SBP from calcified cartilage; hence, they are measured as 1 entity. To enhance reproducibility and comparability, we recommend standardized volumes of interest that include all mineralized tissues from the articular surface to the growth plate. Given the structural differences between SBP and subchondral trabecular bone, a consistent method for defining their boundary is strongly recommended. Data should be reported using robust, easily implementable metrics such as volume and thickness, with additional parameters (eg, porosity, mineral density) included as appropriate. Commonly used metrics such as SBP thickness and volume should continue to be used. When SBP and calcified cartilage cannot be distinguished, we recommend using the subchondral mineralized plate nomenclature.

来源:JBMR Plus,查看原文。版权归原作者所有。

引用

  1. Liberati, van Lenthe. Micro-CT-based analysis of the murine osteochondral unit: a review and recommendations for standardized subchondral bone assessment. JBMR Plus. 2026. PMID: 42376341. doi:10.1093/jbmrpl/ziag068

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。