文献速递儿科影像胸部心血管CT

深度学习自动评估法洛四联症肺动脉指数与手术分流

Deep learning-based automated assessment of pulmonary artery indices and surgical approach triage for tetralogy of Fallot from multicenter cardiac computed tomography (CT).
PubMed 文献 · Clin Radiol · 2026-06-02

本研究基于多中心小儿法洛四联症心脏CT,开发深度学习框架自动分割肺动脉与降主动脉并计算肺动脉指数。结果显示分割DSC达0.92–0.98,处理时间缩短90.11%,自动肺动脉指数在规则手术分流中AUC>0.87。

要点

  • 深度学习自动分割肺动脉与降主动脉,DSC达0.92–0.98,可用于法洛四联症术前CT评估。
  • 自动测量肺动脉指数与人工测量一致性良好,处理时间由205.00秒降至30.28秒。
  • 自动肺动脉指数在规则手术分流中AUC>0.87,提示可辅助临床决策。

核心结论

  • 自动化框架可在多中心数据中快速量化法洛四联症小儿心脏CT的肺动脉指数。
  • 深度学习衍生的肺动脉指数在规则手术分流中与人工测量表现相当。

研究设计与样本

  • 研究纳入122例法洛四联症患儿术前心脏CT,训练集80例,内部验证集20例,外部数据集22例。
  • 采用改良3D nnU-Net架构自动分割肺动脉与降主动脉,研究类型为多中心回顾性研究。

关键影像表现/征象

  • 改良3D nnU-Net对肺动脉与降主动脉的分割Dice相似系数在各数据集中为0.92–0.98。

诊断标准与关键数值

  • 自动肺动脉指数在规则手术分流中的AUC大于0.87。
  • 处理时间由205.00秒缩短至30.28秒,减少90.11%,P<0.001。

临床应用与阅片要点

  • 日常阅片可借助该自动框架快速提取法洛四联症肺动脉指数,辅助术前手术分流评估。
  • 自动分割联合几何算法可减少测量时间,但需注意外部数据集中姑息性病例缺失可能影响分流分析。

局限性

  • 手术分流分析仅在内部数据集进行,因外部数据集缺少姑息性病例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To develop an automated framework for deep learning (DL)-based segmentation, pulmonary artery indices (PAIs) computation, and rule-based surgical triage from cardiac CT (CCT) in pediatric Tetralogy of Fallot (TOF).

MATERIALS AND METHODS: Preoperative CCT scans of pediatric TOF patients were collected from the primary internal centers and two external centers. A modified 3D nnU-Net architecture was used for automated segmentation of the pulmonary arteries (PA) and descending aorta (DAO). Following segmentation, PAIs were automatically computed using predefined geometric algorithms. Segmentation performance, measurement agreement, and processing efficiency were evaluated. Surgical triage analysis was performed only in the primary internal dataset because the external dataset lacked palliative cases.

RESULTS: 122 TOF patients were included (the training dataset n = 80, the internal validation dataset n = 20, the external dataset n = 22). The DL model achieved high segmentation performance, with PA/DAO dice similarity coefficient ranging (DSC) from 0.92 to 0.98 across datasets. DL-derived PAIs showed good agreement with manual measurements and reduced processing time by 90.11% (30.28 s vs. 205.00 s, P < 0.001). Automated PAIs demonstrated good rule-based surgical triage ability (AUC > 0.87).

CONCLUSIONS: This automated framework enables rapid and automated PAI quantification from CCT in pediatric TOF across multi-center datasets. DL-derived PAIs demonstrated comparable performance to manual measurements for rule-based surgical triage.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Yao, Zhou, Guo, et al. Deep learning-based automated assessment of pulmonary artery indices and surgical approach triage for tetralogy of Fallot from multicenter cardiac computed tomography (CT). Clin Radiol. 2026. PMID: 42349352. doi:10.1016/j.crad.2026.107404

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。