文献速递神经US

低频聚焦超声经BDNF通路增强海马神经发生

Low-Intensity Focused Ultrasound Enhances Hippocampal Neurogenesis via BDNF Pathways: Toward a Regenerative Modality for CNS Recovery.
PubMed 文献 · Ultrasound Med Biol · 2026-06-25

本研究在成年大鼠中评估经颅低强度聚焦超声对海马齿状回神经发生的影响。大鼠接受0.5、1或5 MHz刺激,每周两次持续4周。结果显示0.5 MHz组BrdU阳性细胞增加最明显,BDNF、FGF-2、Sox-2 mRNA表达升高,且新物体识别记忆改善,提示频率是调控海马可塑性的关键因素。

要点

  • 0.5 MHz低频刺激对海马神经发生的促进作用优于1 MHz和5 MHz。
  • 低频超声可上调BDNF、FGF-2、Sox-2表达,机制涉及机械转导通路。
  • 0.5 MHz组出现行为学记忆改善,提示超声参数选择影响认知效应。

核心结论

  • 低强度聚焦超声以频率依赖的方式调节成年海马神经发生,0.5 MHz效果最显著。
  • 0.5 MHz刺激显著升高BDNF、FGF-2、Sox-2 mRNA表达,并改善识别记忆。

研究设计与样本

  • 动物实验研究,采用成年大鼠,接受经颅低强度聚焦超声靶向齿状回。
  • 刺激频率为0.5、1、5 MHz,每周两次,持续4周,设假刺激对照组。
  • 细胞增殖以BrdU掺入评估,神经元分化以BrdU/NeuN双标评估。
  • 神经发生调控因子BDNF、FGF-2、Sox-2海马表达以qRT-PCR定量。
  • 认知功能采用新物体识别任务评估。

诊断标准与关键数值

  • 0.5 MHz组齿状回BrdU阳性细胞增加最显著,1 MHz和5 MHz效应较弱。
  • 0.5 MHz组BDNF、FGF-2、Sox-2 mRNA表达显著高于假刺激对照组。
  • 新物体识别记忆改善仅见于0.5 MHz组。

局限性

  • 本研究为动物实验,结果向临床转化尚需人体研究验证。
  • 未报告长期安全性及超声参数优化的剂量-效应关系。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Adult hippocampal neurogenesis is essential for learning, memory, and structural plasticity, yet the mechanisms through which physical neuromodulatory stimuli regulate this process remain incompletely understood. Here, we investigated whether transcranial low-intensity focused ultrasound (LIFU) modulates adult hippocampal neurogenesis in a frequency-dependent manner. Adult rats received LIFU targeting the dentate gyrus at 0.5, 1, or 5 MHz twice weekly for 4 wk. Cellular proliferation was assessed using BrdU incorporation, neuronal differentiation was evaluated by BrdU/NeuN co-labeling, and hippocampal expression of neurogenic regulators (BDNF, FGF-2, and Sox-2) was quantified by qRT-PCR. Cognitive performance was examined using the novel object recognition task. Low-frequency stimulation (0.5 MHz) produced the most pronounced increase in BrdU-positive cells across the dentate gyrus and significantly elevated BDNF, FGF-2, and Sox-2 mRNA expression compared with sham controls. Intermediate (1 MHz) and higher (5 MHz) frequencies produced more modest effects. Behavioral testing revealed improved recognition memory selectively in the 0.5 MHz group, consistent with enhanced hippocampal plasticity. These findings demonstrate that ultrasound frequency critically shapes neurogenic and cognitive responses, supporting mechanotransduction-dependent regulation of adult hippocampal plasticity.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Kanaan, Badawe, Abou-Kheir, et al. Low-Intensity Focused Ultrasound Enhances Hippocampal Neurogenesis via BDNF Pathways: Toward a Regenerative Modality for CNS Recovery. Ultrasound Med Biol. 2026. PMID: 42350197. doi:10.1016/j.ultrasmedbio.2026.05.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。