乳腺超声非肿块病变:附加信息对阅片一致性与诊断效能的影响
本研究回顾性纳入307个乳腺非肿块病变,由4名不同年资乳腺放射科医生在仅超声图像和附加临床及影像信息两种条件下独立评估。结果显示附加信息使敏感度升高、特异度与准确度下降;乳腺X线钙化倾向改善诊断,可疑MRI发现倾向导致假阳性。
要点
- 附加临床与影像信息会提高敏感度但降低特异度,需警惕过度诊断。
- 可疑MRI发现易导致假阳性,阅片时避免被MRI结论过度锚定。
- 乳腺X线钙化信息有助于提高超声诊断准确率。
核心结论
- 乳腺超声非肿块病变评估的阅片者内一致性为高度一致,阅片者间一致性为中度至高度一致。
- 附加临床及影像信息使敏感度升高、特异度与准确度下降。
- 乳腺X线钙化倾向提高诊断准确率,可疑MRI发现倾向导致假阳性并降低特异度。
研究设计与样本
- 回顾性单中心研究,纳入2022年1月至6月活检证实的非肿块病变及未经组织学证实的良性非肿块病变。
- 共分析307个非肿块病变,来自299名女性,平均年龄53.9±11.9岁。
- 4名乳腺放射科医生在两次独立阅片中评估病变:首次仅依据超声图像,第二次附加临床及其他影像信息。
- 采用κ统计量评价阅片一致性,并比较诊断效能及分析评估改变的影响因素。
诊断标准与关键数值
- 阅片者内一致性κ=0.650-0.772,为高度一致。
- 首次阅片者间一致性κ=0.501-0.562,为中度至高度一致。
- 二次阅片者间一致性κ=0.612-0.709,为中度至高度一致。
- 附加信息后敏感度升高,P<0.05。
- 附加信息后特异度降低,P<0.001。
临床应用与阅片要点
- 报告乳腺超声非肿块病变时,应意识到附加信息会改变诊断阈值与准确度。
- 遇可疑MRI发现时,避免直接上调超声BI-RADS分类,防止特异度下降。
- 参考乳腺X线钙化信息有助于提升非肿块病变的诊断准确率。
- 阅片一致性受附加信息影响而提高,提示结构化提供临床与影像背景有助于稳定判读。
局限性
- 回顾性单中心研究设计。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The interpretation of non-mass lesions (NMLs) on ultrasound remains variable, and the impact of clinical and additional imaging information on diagnostic performance has not been systematically evaluated.
PURPOSE: To evaluate intra- and inter-reader agreement in ultrasound assessment of NMLs among breast radiologists with different experience levels, with and without clinical or additional imaging information, and to analyze diagnostic performance and identify factors contributing to changes in assessment.
METHODS: This retrospective, single-center study included biopsy-proven NMLs, and benign NMLs without tissue confirmation, conducted between January and June 2022. Four breast radiologists independently assessed the NMLs in two sessions: primary (ultrasound images only) and secondary (with clinical and additional imaging information). Reader agreement was evaluated using κ statistics. Diagnostic performance was compared and changes in assessment were analyzed according to the type of additional information.
RESULTS: 307 NMLs in 299 women (mean age ± standard deviation, 53.9 ± 11.9 years) were analyzed. Intra-reader agreement was substantial (κ = 0.650-0.772), and inter-reader agreement ranged from moderate to substantial (primary κ = 0.501-0.562; secondary κ = 0.612-0.709). When additional information was provided, sensitivity increased (P < 0.05), specificity decreased (P < 0.001) and accuracy decreased (P < 0.01). Mammographic calcifications tended to improve diagnostic accuracy, while suspicious MRI findings were associated with a tendency toward false positive diagnoses.
CONCLUSION: Assessment of NMLs on ultrasound demonstrated consistent reader agreement. Diagnostic performance was influenced by additional imaging information, with calcifications tending to improve diagnosis and MRI findings tending to reduce specificity.
引用
- Yoon, Cha, Choi, et al. Reader agreement and diagnostic performance in breast ultrasound for non-mass lesions: Influence of additional clinical information and imaging modalities. Eur J Radiol. 2026. PMID: 42335827. doi:10.1016/j.ejrad.2026.113027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。