文献速递泌尿生殖腹部MR

前列腺癌包膜外侵犯预测的最佳MRI序列:LCC与MaxRADD比较

Optimal MRI sequence for predicting extraprostatic extension in prostate cancer: comparison of LCC and MaxRADD measurements.
PubMed 文献 · Abdom Radiol (NY) · 2026-06-24

回顾性纳入63例前列腺癌根治术患者共105个病灶,由两名放射科医生在T2WI、DWI、ADC和DCE上测量LCC与MaxRADD,以组织病理学为参考标准。结果显示DCE上LCC诊断效能最高,14 mm阈值敏感度90%、特异度96.6%、AUC 0.93;联合MaxRADD后AUC升至0.96但与单用LCC无显著差异。

要点

  • DCE序列上LCC 14 mm为预测EPE的最佳阈值,AUC达0.93。
  • LCC在10 mm与15 mm阈值间预测效能存在显著差异,报告时需注明阈值。
  • 联合LCC与MaxRADD仅数值上提升AUC,未显著优于单用LCC。

核心结论

  • DCE序列上LCC测量对预测前列腺癌EPE具有最高诊断效能,14 mm LCC阈值和11 mm MaxRADD阈值总体准确性最佳。
  • 联合LCC与MaxRADD使AUC由0.93升至0.96,但差异无统计学意义(p = 0.270)。

研究设计与样本

  • 回顾性研究,纳入2018年至2020年63例活检证实前列腺癌并行根治术且术前有mpMRI的患者,共105个可评估病灶。
  • 由两名放射科医生在T2WI、DWI、ADC图和DCE序列上测量LCC与MaxRADD,以组织病理学为参考标准。
  • LCC采用基于PI-RADS和ESUR指南的10 mm与15 mm阈值进行评估。

关键影像表现/征象

  • DCE序列显示的前列腺癌病灶与包膜接触长度及最大径向距离是预测EPE的关键影像征象。
  • LCC在10 mm与15 mm阈值之间预测EPE效能存在显著差异。

诊断标准与关键数值

  • LCC 10 mm阈值:DCE敏感度最高(90.1%),特异度80.7%。
  • LCC 15 mm阈值:DCE特异度更高(94.7%),敏感度85%。
  • ROC分析确定DCE上14 mm为最佳LCC阈值,敏感度90%、特异度96.6%、AUC 0.93。
  • MaxRADD在DCE上11 mm阈值表现最佳,敏感度65%、特异度88.5%。
  • MaxRADD各序列AUC:DCE 0.83、T2WI 0.80、DWI 0.78、ADC 0.74,差异无显著性。

临床应用与阅片要点

  • 日常阅片预测EPE时优先在DCE序列测量LCC,14 mm可作为提示包膜外侵犯的参考界值。
  • 报告LCC测量结果时需明确所用阈值,10 mm与15 mm对应敏感度和特异度差异显著。
  • MaxRADD可作为补充测量指标,DCE上11 mm阈值特异度较高。

局限性

  • 回顾性研究设计,样本量较小且为单中心。
  • 联合LCC与MaxRADD较单用LCC未显示统计学显著优势。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Accurate preoperative identification of extraprostatic extension (EPE) in prostate cancer (PCa) is important for treatment strategies. This retrospective study aimed to determine which MRI sequence provides the most accurate measurement of length of capsular contact (LCC) and maximum lesion radial distance (MaxRADD) for predicting EPE.

METHODS: We included 63 patients who underwent radical prostatectomy for biopsy-confirmed PCa and had preoperative multiparametric MRI (mpMRI) from 2018 to 2020. Two radiologists measured LCC and MaxRADD on T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), apparent diffusion coefficient (ADC) maps, and dynamic contrast-enhanced (DCE) sequences. LCC was evaluated using 10 mm and 15 mm thresholds based on Prostate Imaging-Reporting and Data System (PI-RADS) and European Society of Urogenital Radiology (ESUR) guidelines. Histopathology was the reference standard. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated.

RESULTS: 63 patients with 105 evaluable lesions were included. Significant differences were observed between the 10 mm and 15 mm LCC thresholds for predicting EPE. At 10 mm, DCE demonstrated the highest sensitivity (90.1%) and a 80.7% specificity. At 15 mm, DCE achieved higher specificity (94.7%) with 85% sensitivity. ROC analysis identified 14 mm on DCE as the optimal LCC threshold, reaching 90% sensitivity, 96.6% specificity (AUC:0.93). MaxRADD showed variable diagnostic performance, with the highest AUC on DCE (0.83), T2WI (0.80), DWI (0.78), and ADC (0.74), without significant differences. Combining LCC and MaxRADD slightly improved AUC (0.96 vs. 0.93 for LCC alone, p = 0.270). MaxRADD performed best on DCE at an 11 mm threshold (sensitivity 65%, specificity 88.5%).

CONCLUSION: DCE provides the highest diagnostic performance for predicting EPE using LCC measurements, with a 14 mm LCC and 11 mm MaxRADD threshold yielding the best overall accuracy. Combining LCC and MaxRADD numerically increased AUC (0.96 vs. 0.93), however without significant differences in EPE prediction (p = 0.270).

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Ilanjian, Matthey, Porões, et al. Optimal MRI sequence for predicting extraprostatic extension in prostate cancer: comparison of LCC and MaxRADD measurements. Abdom Radiol (NY). 2026. PMID: 42340465. doi:10.1007/s00261-026-05615-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。