文献速递泌尿生殖MR

前列腺DCE-MRI的厂商中立深度学习重建:图像质量与诊断效能

Vendor-neutral deep learning reconstruction of dynamic contrast-enhanced prostate MRI: Image quality improvement and preservation of diagnostic performance.
PubMed 文献 · Eur J Radiol · 2026-06-17

本研究回顾性纳入173例活检前接受3T前列腺多参数MRI的患者,比较原始DCE图像与厂商中立图像域深度学习重建(DLR)DCE图像的图像质量和临床显著前列腺癌(csPCa)诊断效能。两位放射科医师独立评估,结果显示DLR改善图像噪声、包膜清晰度、病灶显著性,且PI-RADS诊断效能未见显著差异。

要点

  • DLR可改善前列腺DCE图像的噪声、包膜清晰度和病灶显著性,有助于日常阅片。
  • DLR DCE图像导致更多PI-RADS 4-5评估、更少PI-RADS 3+1升级评估。
  • DLR重建后PI-RADS分类和DCE阳性评估的观察者间一致性提高。

核心结论

  • 厂商中立图像域DLR在保持基于PI-RADS的csPCa诊断效能的同时,改善了前列腺DCE图像的定性图像质量。

研究设计与样本

  • 两位放射科医师独立盲法评估原始DCE与DLR DCE图像组成的mpMRI图像集。
  • 该研究为单中心回顾性设计,活检前MRI均采用多参数序列。

关键影像表现/征象

  • DLR DCE图像在噪声、包膜清晰度、病灶显著性和DCE阳性评估信心方面均优于原始DCE图像。
  • DLR DCE图像的纹理自然度较原始DCE图像更低,差异有统计学意义。
  • DLR DCE图像导致更少的PI-RADS 3+1评估和更多的PI-RADS 4-5评估。

诊断标准与关键数值

  • PI-RADS ≥ 4阈值下,Reader 2对DLR DCE图像的敏感度为88.5%,对原始DCE图像为75.4%,P=0.027。
  • csPCa定义为分级组≥2,采用ROC曲线分析比较AUC,两图像集之间AUC无显著差异。

临床应用与阅片要点

  • 在日常阅片中,DLR可改善DCE图像的噪声和病灶显著性,有利于对DCE阳性评估的信心。
  • 采用DLR DCE图像时需注意纹理自然度降低,不应将其误判为病理性改变。
  • DLR重建可能改变PI-RADS分类分布,尤其是减少PI-RADS 3+1升级评估的频率。

局限性

  • 该研究为单中心回顾性设计,DLR应用方式为回顾性施加于DCE图像。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the effects of vendor-neutral image-domain deep learning reconstruction (DLR) applied retrospectively to dynamic contrast-enhanced (DCE) images from prostate multiparametric magnetic resonance imaging (MRI) on image quality and diagnostic performance for clinically significant prostate cancer (csPCa).

MATERIALS AND METHODS: This retrospective study included 173 patients who underwent prebiopsy 3T prostate MRI from January 2016 to December 2022 before biopsy. Two radiologists independently assessed qualitative image quality and assigned Prostate Imaging Reporting and Data System (PI-RADS) version 2.1 scores in blinded sessions using multiparametric MRI (mpMRI) sets with original or DLR DCE images. PI-RADS 3+1 denoted DCE-driven upgrading of peripheral zone diffusion-weighted imaging category 3 lesions. Diagnostic performance for csPCa, defined as grade group ≥ 2, was evaluated using receiver operating characteristic curve analysis with area under the curve (AUC) and binary metrics.

RESULTS: DLR DCE images showed improved image noise, capsule sharpness, lesion conspicuity, and confidence in assessing DCE positivity (all P < 0.01) for both readers. Image texture naturalness was lower with DLR DCE images (P < 0.001). The AUC values did not differ significantly between the two mpMRI sets. At the PI-RADS ≥ 4 threshold, Reader 2 showed higher sensitivity with DLR DCE images than with original DCE images (88.5 % vs. 75.4 %, P = 0.027). DLR DCE images yielded fewer PI-RADS 3+1 and more PI-RADS 4-5 assessments. Interreader agreement for PI-RADS categorization and DCE positivity was greater with DLR DCE images.

CONCLUSION: Vendor-neutral image-domain DLR improved the qualitative image quality of prostate DCE images while preserving PI-RADS-based diagnostic performance for csPCa.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Lee, Choi, Kim, et al. Vendor-neutral deep learning reconstruction of dynamic contrast-enhanced prostate MRI: Image quality improvement and preservation of diagnostic performance. Eur J Radiol. 2026. PMID: 42322720. doi:10.1016/j.ejrad.2026.113020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。