指南与共识头颈技术与安全US

基于共识的唾液腺超声评分系统用于泪腺:OMERACT 静态图像可靠性研究

Applying the consensus-based salivary glands ultrasound scoring system in lacrimal glands: results of a static image-based OMERACT reliability exercise.
指南 / 共识 · Semin Arthritis Rheum · 2026-06-11

该研究采用 OMERACT 针对原发性干燥综合征开发的唾液腺半定量超声评分系统(0-3 分),评估其用于泪腺静态图像时的可靠性。14 名风湿科医生参与阅片,结果显示观察者内一致性良好至优(kappa 0.63-1.00),观察者间一致性良好(kappa 0.63)。下一步需验证视频片段及实时操作中的可靠性。

要点

  • 唾液腺超声 0-3 分评分系统可用于泪腺静态图像,观察者间一致性良好。
  • 多数阅片者无泪腺超声经验但具唾液腺超声经验,仍获较好一致性。
  • 日常报告中应注意该评分尚未在实时超声中验证可靠性。

核心结论

  • 基于共识的唾液腺半定量超声评分系统应用于泪腺静态图像时,观察者内可靠性良好至优,观察者间可靠性良好。

研究设计与样本

  • 静态图像可靠性研究;14 名风湿科医生参与;采用 6-24 MHz 线阵曲棍球棒探头采集图像;受试者为疑似原发性干燥综合征患者。
  • 参与者肌骨超声经验 2-28 年,唾液腺超声经验 0-12 年;11/14 无泪腺超声经验,13/14 有唾液腺超声经验。
  • 统计学方法采用 Kappa 统计量。

关键影像表现/征象

  • 泪腺实质改变按唾液腺半定量评分系统分为 0-3 级,用于反映不同等级的实质回声改变。

诊断标准与关键数值

  • 观察者内可靠性 Kappa 值为 0.63-1.00(95% CI: 0.77-0.89)。
  • 观察者间可靠性 Kappa 值为 0.63(95% CI: 0.61-0.65)。
  • 评分系统为 0-3 分半定量分级,参照 OMERACT 唾液腺超声评分系统开发。

临床应用与阅片要点

  • 有唾液腺超声经验的医生可将该 0-3 分评分系统用于泪腺静态图像评估。
  • 阅片时重点观察泪腺实质回声的分级改变,按 0-3 级进行半定量评分。
  • 缺乏泪腺超声经验的医生经标准化评分培训后亦可获较好一致性。

局限性

  • 研究仅基于静态图像,未评估视频片段及实时操作中的评分可靠性。
  • 多数参与者此前无泪腺超声操作经验。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study tested the reliability of an ultrasound scoring system (0-3) for lacrimal glands using an OMERACT semi-quantitative ultrasound scoring system developed for salivary glands in primary Sjögrens Disease pSjD).

METHODS: Fourteen rheumatologists participated in a static image exercise on ultrasound images in order to evaluate the reliability of the existing salivary gland ultrasound (SGUS) scoring system when applied to lacrimal glands. All images were obtained from patients with suspected pSjD using a 6-24 MHz linear hockey stick transducer. One hundred images representing different grades of parenchyma changes in the lacrimal glands were collected for the inter-observer analyses and 32 of these were repeated to assess intra-observer reliability. Kappa statistics were applied.

RESULTS: Participants had musculoskeletal ultrasound experience ranging from 2-28 years, and SGUS experience from 0-12 years. The majority (11/14) had no prior experience in lacrimal gland ultrasound but 13/14 had experience in SGUS. Intra-observer reliability was good to excellent, with kappa values ranging from 0.63 to 1.00 (95% CI: 0.77-0.89). Inter-observer reliability showed good agreement, with a kappa of 0.63 (95% CI: 0.61-0.65).

CONCLUSION: The consensus-based semi-quantitative ultrasound scoring system for salivary glands showed good to excellent intra-observer and good inter-observer reliability when applied to the lacrimal glands using static images. The next step is to assess the reliability when scoring lacrimal glands in video-clips and in live exercises.

来源:Semin Arthritis Rheum,查看原文。版权归原作者所有。

引用

  1. Terslev, Schmidt, Fana, et al. Applying the consensus-based salivary glands ultrasound scoring system in lacrimal glands: results of a static image-based OMERACT reliability exercise. Semin Arthritis Rheum. 2026. PMID: 42320459. doi:10.1016/j.semarthrit.2026.153019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。