回顾性纳入206例子宫内膜癌患者,其中130例来自A医院用于训练与内部测试,76例来自B医院用于外部测试。比较基于小视野DWI与常规DWI的影像组学模型预测显著/广泛LVSI的效能。结果:内部测试中小视野DWI模型AUC为0.90,常规DWI模型AUC为0.89,外部测试中小视野DWI模型AUC降至0.74。

要点

  • 小视野DWI模型敏感性达1.00,可辅助术前排除显著LVSI低风险患者。
  • DWI/ADC纹理特征重要性高于T2WI,阅片时应重点观察扩散相关特征。
  • 外部验证性能下降,多中心数据下应谨慎解读模型输出结果。

核心结论

  • 小视野DWI模型敏感性更高,但AUC与常规DWI模型相比无显著优势。
  • 外部测试性能下降,提示该模型在多中心临床实施前需进一步验证。

研究设计与样本

  • 回顾性研究,共206例子宫内膜癌患者,A医院130例用于训练与内部测试,B医院76例用于外部测试。
  • 从T2WI、小视野DWI/ADC提取全肿瘤影像组学特征,A医院病例另提取常规DWI/ADC特征。
  • 开发两个校准梯度提升树分类器:小视野DWI模型与常规DWI模型。
  • 以分层自助法计算AUC及95%CI评估区分度,并在测试集中评估泛化性。

诊断标准与关键数值

  • 内部测试集:小视野DWI模型AUC为0.90(95%CI,0.77-1.00),敏感性1.00,特异性0.77,平衡准确率0.89。
  • 内部测试集:常规DWI模型AUC为0.89(95%CI,0.72-1.00),敏感性0.75,特异性0.68,平衡准确率0.72。
  • 外部测试集:小视野DWI模型AUC为0.74(95%CI,0.56-0.90)。
  • 特征重要性分析显示扩散相关纹理特征占优势,两个模型中DWI/ADC特征权重均高于T2WI。

临床应用与阅片要点

  • 小视野DWI影像组学对术前预测显著LVSI具有潜在价值,可用于辅助FIGO 2023分期决策。
  • 该模型敏感性高但特异性中等,阳性预测结果需结合其他临床病理信息综合判断。
  • 外部验证中AUC下降,临床应用前建议评估本地设备序列数据与训练集的差异。
  • 报告DWI/ADC纹理特征异常时应注意该特征对LVSI预测的贡献高于T2WI特征。

局限性

  • 外部测试集仅涵盖小视野DWI模型,常规DWI模型缺乏外部验证。
  • 外部测试中性能下降,尽管实施了数据协调处理,仍提示跨中心泛化存在局限。
  • 回顾性设计及有限的样本量可能限制模型效能评估的稳健性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The revised FIGO 2023 for endometrial cancer (EC) incorporates lymphovascular space invasion (LVSI) into staging and explicitly designates only substantial/extensive LVSI as adverse. While reduced field-of-view diffusion-weighted imaging (rFOV DWI) improves image quality and staging accuracy for EC, its potential for radiomics-based LVSI assessment remains underexplored. We compared radiomics models based on rFOV DWI and conventional DWI (cDWI) for preoperative prediction of substantial/extensive LVSI and assessed external generalizability.

MATERIALS AND METHODS: We included 206 patients: 130 from Hospital A (training/internal test) and 76 from Hospital B (external rFOV DWI test). Whole-tumor radiomics features were extracted from T2WI, rFOV DWI/ADC, and-at Hospital A only-cDWI/ADC. Two calibrated gradient-boosted tree classifiers were developed: rFOV DWI and cDWI models. Discrimination was summarized by AUC with 95 % CIs from stratified bootstrap; generalizability was evaluated in the test sets.

RESULTS: On the internal test set, the rFOV DWI model achieved an AUC of 0.90 (95 % CI, 0.77-1.00) with sensitivity 1.00, specificity 0.77, and balanced accuracy 0.89; the cDWI model showed an AUC of 0.89 (95 % CI, 0.72-1.00) with sensitivity 0.75, specificity 0.68, and balanced accuracy 0.72. On the external test set, the rFOV DWI model yielded an AUC of 0.74 (95 % CI, 0.56-0.90). Feature importance favored diffusion-related textures; in both models, DWI/ADC features outweighed T2WI.

CONCLUSION: The rFOV DWI-based model achieved higher sensitivity without a significant AUC advantage over cDWI. External testing showed a decline in performance despite harmonization. Multicenter validation is required before clinical implementation.

来源:Eur J Radiol,查看原文。版权归原作者所有。