深度学习重建改善胸部MRI质量并与CT诊断一致性高
该前瞻性研究纳入54例CT可见肺病变患者,行3.0T胸部MRI,比较有无深度学习重建的图像质量及与CT的病变特征一致性。结果显示DLR显著降低噪声、提高信噪比与对比噪声比,形态学特征与CT一致性高,病变测量一致性极佳。
要点
- DLR重建可显著改善胸部MRI图像质量与病灶边缘清晰度
- DLR MRI在分叶、结节类型、形态及胸膜凹陷上与CT一致性高
- DLR MRI可作为无电离辐射的肺病变随访影像补充手段
核心结论
- DLR可改善胸部MRI图像质量,且对已知肺病变的评估与CT具有较高一致性,支持其作为无电离辐射的随访影像补充手段
研究设计与样本
- 前瞻性研究,纳入54例CT可见肺病变患者,2022年9月至2024年9月行3.0T胸部MRI
- 序列包含脂肪抑制T2加权成像及平扫/增强三维肝脏容积快速采集序列,均分别行有DLR和无DLR重建
- 由两名高年资放射科医生以共识方式用5分制评分评价解剖清晰度、伪影严重程度和病灶边缘锐利度
关键影像表现/征象
- DLR重建后T2加权图像上病灶边缘锐利度评分由3.78±0.46提升至4.70±0.50
- DLR MRI与CT在分叶、结节类型、形态和胸膜凹陷方面一致性很高,κ值为0.902至1.00
诊断标准与关键数值
- T2加权图像病灶信噪比中位数由186.8提高至394.8(P<0.001)
- DLR MRI与CT病灶大小测量一致性极佳,组内相关系数为0.972
临床应用与阅片要点
- DLR重建可在不改变扫描方案的情况下提升胸部MRI病灶显示能力
- 评估已知肺病变的形态学特征时,DLR MRI可作为CT的可靠对照影像
- 对需要减少电离辐射暴露的肺病变随访患者,可考虑采用DLR胸部MRI
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate whether deep learning reconstruction (DLR) improves chest magnetic resonance imaging (MRI) image quality and to assess the agreement between DLR MRI and computed tomography (CT) for characterization of known pulmonary lesions.
METHODS: This prospective study included 54 patients with CT-visible pulmonary lesions who underwent 3.0-T chest MRI between September 2022 and September 2024. T2-weighted imaging with fat suppression and unenhanced/enhanced three-dimensional liver acquisition with volume acceleration were reconstructed with and without DLR. Quantitative image quality was assessed using background noise, signal-to-noise ratio, and contrast-to-noise ratio. Qualitative image quality was evaluated by two senior radiologists in consensus using 5-point scales for anatomical clarity, artifact severity, and lesion edge sharpness. Morphological features and lesion diameter measurements were compared between DLR MRI and CT.
RESULTS: DLR significantly reduced background noise and improved signal-to-noise and contrast-to-noise ratios across all MRI sequences. For example, median lesion signal-to-noise ratio on T2-weighted images increased from 186.8 to 394.8 after DLR reconstruction (P < 0.001). Qualitative scores also improved significantly, with lesion edge sharpness increasing from 3.78 ± 0.46 to 4.70 ± 0.50 on T2-weighted images (P < 0.001). DLR MRI showed high agreement with CT for lobulation, nodule type, shape, and pleural indentation (κ = 0.902-1.00). Lesion size measurements showed excellent agreement between DLR MRI and CT (ICC = 0.972).
CONCLUSION: DLR improves chest MRI image quality and shows high agreement with CT for assessing known pulmonary lesions, supporting its potential use as a non-ionizing adjunct for follow-up imaging.
引用
- Jiang, Liu, Xu, et al. Deep learning reconstruction for chest MRI: image quality and diagnostic agreement with CT. Eur J Radiol. 2026. PMID: 42314619. doi:10.1016/j.ejrad.2026.113008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。