文献速递外周血管神经US

颈动脉支架术后再狭窄的术前超声综合预测模型

Synergistic Predictive Effect Of Preoperative Integrated Assessment of Plaque Characteristics, Vascular Compliance and Blood Flow Parameters on the Risk of Restenosis After Symptomatic Carotid Artery Stenting.
PubMed 文献 · Ultrasound Med Biol · 2026-06-17

回顾性分析335例症状性颈动脉支架术患者,以术后1年再狭窄分组,并用60例前瞻性队列验证。采用LASSO回归及多因素logistic回归筛选变量并构建列线图。模型AUC达0.910,验证队列AUC为0.886,显示良好的区分度与校准度。

要点

  • 斑块钙化、DC、SI、AC及PSV是CAS术后再狭窄的独立预测因素。
  • 术前超声综合评估可用于CAS术后再狭窄风险分层。
  • 列线图在阈值概率0.05–0.8范围内具有正向净获益。

核心结论

  • 整合术前斑块特征、血管顺应性及血流参数的列线图可有效预测CAS术后再狭窄风险。

研究设计与样本

  • 回顾性研究纳入2021年1月至2024年1月335例症状性CAS患者作为建模队列,按1年随访结果分为再狭窄组与非再狭窄组。
  • 前瞻性验证队列纳入2024年2月至10月60例患者。
  • 特征筛选采用LASSO回归,独立预测因素通过多因素logistic回归确定并构建列线图。

关键影像表现/征象

  • 组间斑块回声、形态、钙化、DC、SI、AC及PSV存在显著差异(p均小于0.05)。

诊断标准与关键数值

  • 斑块钙化OR为2.454(95%CI 1.457–4.133)。
  • DC的OR为0.383(95%CI 0.224–0.655)。
  • SI的OR为1.580(95%CI 1.244–2.007)。
  • AC的OR为0.329(95%CI 0.182–0.596)。
  • PSV的OR为1.644(95%CI 1.279–2.113)。

临床应用与阅片要点

  • 术前超声评估斑块钙化、DC、SI、AC及PSV有助于识别CAS术后高再狭窄风险患者。
  • 列线图在阈值概率0.05–0.8范围内提供正向净获益,可用于个体化术后管理决策。

局限性

  • 建模队列为回顾性设计,存在选择偏倚可能。
  • 验证队列样本量仅60例,外推性有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the synergistic predictive value of an integrated preoperative assessment incorporating plaque characteristics, vascular compliance, and blood flow parameters for restenosis risk after symptomatic carotid artery stenting (CAS).

METHODS: This retrospective study analyzed 335 patients who underwent CAS (January 2021-January 2024) as a derivation cohort, classified into restenosis and non-restenosis groups based on 1-year follow-up. A prospective validation cohort included 60 additional patients (February-October 2024). Preoperative clinical and ultrasound data were compared. Feature selection was performed using least absolute shrinkage and selection operator (LASSO) regression. Independent predictors were identified via multivariate logistic regression, and a nomogram was constructed. The model's performance was assessed using the area under the receiver operating characteristic curve (AUC), calibration curves, and decision curve analysis to evaluate discrimination, calibration, and net benefit.

RESULTS: Significant differences were found in plaque echo, shape, calcification, distensibility coefficient (DC), stiffness index (SI), arterial compliance (AC), and peak systolic velocity (PSV) between groups (p < 0.05). LASSO regression selected five variables. Multivariate analysis confirmed plaque calcification (OR = 2.454, 95% CI: 1.457-4.133), DC (OR = 0.383, 95% CI: 0.224-0.655), SI (OR = 1.580, 95% CI: 1.244-2.007), AC (OR = 0.329, 95% CI: 0.182-0.596), and PSV (OR = 1.644, 95% CI: 1.279-2.113) as independent predictors (all p < 0.05). The model demonstrated excellent discrimination (AUC = 0.910, 95% CI: 0.868-0.953) and good calibration (p = 0.223), providing positive net benefit across threshold probabilities of 0.05-0.8. Validation confirmed robust performance (AUC = 0.886, 95% CI: 0.788-0.985; calibration p = 0.226).

CONCLUSION: A nomogram integrating preoperative plaque characteristics, vascular compliance, and hemodynamic parameters effectively predicts restenosis risk after CAS, supporting early risk stratification and personalized postoperative management to improve long-term patient outcomes.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Tian, Liu, Wang, et al. Synergistic Predictive Effect Of Preoperative Integrated Assessment of Plaque Characteristics, Vascular Compliance and Blood Flow Parameters on the Risk of Restenosis After Symptomatic Carotid Artery Stenting. Ultrasound Med Biol. 2026. PMID: 42309881. doi:10.1016/j.ultrasmedbio.2026.05.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。