文献速递腹部技术与安全CT

深度学习检测胰腺癌CT直接与间接征象

Deep Learning Detection of Direct and Indirect Imaging Findings Associated with Pancreatic Cancer at Contrast-enhanced and Noncontrast CT.
PubMed 文献 · Radiology · 2026-01-01

本研究回顾性纳入2251例患者,开发基于平扫CT和增强CT的深度学习模型,用于检测胰腺肿块、实质萎缩、主胰管扩张及狭窄并诊断胰腺癌。结果显示模型诊断性能与医师相当或更优,对≤20mm胰腺癌敏感度显著高于医师。

要点

  • 平扫CT模型诊断胰腺癌AUC达0.93,对小胰腺癌敏感度明显高于医师均值。
  • 增强CT模型对≤20mm胰腺癌敏感度达98%,优于医师均值82.6%。
  • 模型可同时输出直接征象(肿块)与间接征象(萎缩、胰管扩张/狭窄),利于结构化报告。

核心结论

  • 深度学习模型在CT图像上可检测胰腺癌直接与间接征象,诊断性能与医师相当或更优,尤其对小胰腺癌敏感度显著更高。

研究设计与样本

  • 分别基于平扫CT和增强CT开发两个深度学习模型,训练与验证来自多机构人工标注的CT扫描,使用两个外部测试集进行模型评估。
  • 胰腺癌诊断参考标准为组织病理学确认,模型检测征象及诊断性能与六位医师进行比较,采用ROC曲线分析评估诊断效能。

关键影像表现/征象

  • 模型检测的影像征象包括胰腺肿块(直接征象)与实质萎缩、主胰管扩张、主胰管狭窄(间接征象)。

诊断标准与关键数值

  • 增强CT集中检测胰腺肿块AUC为0.94,实质萎缩AUC为0.90,主胰管扩张AUC为0.94,主胰管狭窄AUC为0.94。
  • 平扫CT集中检测胰腺肿块AUC为0.88,实质萎缩AUC为0.88,主胰管扩张AUC为0.95,主胰管狭窄AUC为0.93。

临床应用与阅片要点

  • 平扫CT模型对小胰腺癌敏感度较医师提升明显,可用于平扫CT筛查场景下辅助识别可能漏诊的小病灶。
  • 模型同时输出直接和间接征象,有助于在报告中系统化评估胰腺癌相关表现,减少单一征象依赖。

局限性

  • 回顾性研究设计存在选择偏倚可能。
  • 未报告模型在外部测试集中的具体样本量及多中心设备差异对结果的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Deep learning (DL) models have shown promise in diagnosing pancreatic cancer (PC); however, models that simultaneously detect both direct and indirect imaging findings associated with PC are lacking. Purpose To develop and evaluate DL models that detect direct and indirect imaging findings on noncontrast CT (NCCT) and contrast-enhanced CT (CECT) images for PC diagnosis. Materials and Methods This retrospective study from August 2007 to December 2022 included patients with PC and control patients. Two DL models were developed using NCCT and CECT to detect direct (pancreatic mass) and indirect (parenchymal atrophy, main pancreatic duct [MPD] dilatation, and MPD stenosis) imaging findings and diagnose PC based on these findings. For training and validation, CT scans from multiple institutions were manually annotated. Model evaluation was performed using two external test sets (CECT and NCCT sets). Receiver operating characteristic curve analysis was used to assess diagnostic performance. Model performance in detecting imaging findings and PC was compared with the performance of six physicians. The reference standard for PC diagnosis was histopathologic confirmation. Results This study included 2251 patients (mean age, 66 years ± 13.3 [SD]; age range, 20-96 years; 850 men). DL models demonstrated area under the receiver operating characteristic curve (AUC) values of 0.94, 0.90, 0.94, and 0.94 in the CECT set and 0.88, 0.88, 0.95, and 0.93 in the NCCT set for detecting pancreatic masses, parenchymal atrophy, MPD dilatation, and MPD stenosis, respectively. For PC diagnosis, DL models performed similarly to or better than the mean of six readers in the CECT (AUC, 0.99 vs 0.99; P = .84) and NCCT (AUC, 0.93 vs 0.91; P = .03) sets. For PCs that were 20 mm or smaller, the DL models demonstrated higher sensitivity than the reader mean in both the CECT (98% vs 82.6%; P < .001) and NCCT (86% vs 41.1%; P < .001) sets. Conclusion DL models detected direct and indirect imaging findings on CT images and diagnosed PC with performance comparable to or better than that of physicians, particularly for small PCs. © RSNA, 2026 Supplemental material is available for this article. See also the editorial by Bhayana and Rajpurkar in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Yamaguchi, Sofue, Masuda, et al. Deep Learning Detection of Direct and Indirect Imaging Findings Associated with Pancreatic Cancer at Contrast-enhanced and Noncontrast CT. Radiology. 2026. PMID: 42301012. doi:10.1148/radiol.253122

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。