文献速递神经MR

T1-T2FLAIR匹配征用于鉴别脑沟良恶性强化

When sulcal enhancement is not leptomeningeal metastasis: diagnostic value of T1-T2FLAIR matching for differentiating benign contrast leakage.
PubMed 文献 · Eur J Radiol · 2026-06-09

这项单中心回顾性研究纳入337例怀疑颅内转移的增强脑MRI患者,观察CE-T2FLAIR上脑沟强化并分为无强化、良性对比剂渗漏或软脑膜转移。结果显示,以T1-T2FLAIR匹配阳性为界,诊断软脑膜转移的敏感度为90.9%、特异度为94.8%;良性渗漏更常见错配并伴随高龄、微出血及放疗史。

要点

  • CE-T2FLAIR脑沟强化不一定代表软脑膜转移,良性对比剂渗漏在延迟增强中并不少见。
  • T1-T2FLAIR错配更支持良性渗漏,匹配则高度提示软脑膜转移。
  • 阅片时应联合CE-T1WI与CE-T2FLAIR判断脑沟强化性质,而不仅凭单一序列。

核心结论

  • CE-T2FLAIR上非肿瘤性脑沟强化在当代神经肿瘤MRI中较常见,尤其延迟增强采集时更明显。
  • 利用CE-T2FLAIR与CE-T1WI脑沟强化是否匹配,可简便有效地鉴别良性对比剂渗漏与软脑膜转移。
  • 以匹配阳性为界,T1-T2FLAIR匹配征诊断软脑膜转移的敏感度为90.9%、特异度为94.8%。

研究设计与样本

  • 回顾性单中心研究,共纳入337例因怀疑颅内转移接受增强脑MRI检查的患者。
  • 由两名神经放射科医生独立判断CE-T2FLAIR与CE-T1WI的T1-T2FLAIR匹配状态。
  • 脑沟强化根据影像与临床标准分为无强化、良性对比剂渗漏和软脑膜转移三类。

关键影像表现/征象

  • CE-T2FLAIR可显示脑沟强化,根据T1-T2FLAIR匹配或错配提示不同性质。
  • 错配模式常见于良性对比剂渗漏,且与年龄较大、脑微出血负荷较高、皮质浅表铁沉积及既往放疗相关。
  • 271例未见软脑膜强化,55例表现为良性对比剂渗漏且年龄大于其他组,11例准确诊断为软脑膜转移。

诊断标准与关键数值

  • 以T1-T2FLAIR匹配阳性作为诊断软脑膜转移的界值时,敏感度为90.9%,特异度为94.8%。
  • CE-T2FLAIR脑沟强化分为无强化、对比剂渗漏或软脑膜转移,分类依据影像和临床标准。

临床应用与阅片要点

  • 在日常神经肿瘤MRI阅片中,发现CE-T2FLAIR脑沟强化时,应同时核对CE-T1WI对应区域强化是否匹配。
  • 仅见CE-T2FLAIR脑沟强化而CE-T1WI不匹配时,优先考虑良性对比剂渗漏而非软脑膜转移。
  • 既往放疗、皮质浅表铁沉积或脑微出血较多患者出现脑沟强化时,应警惕良性渗漏可能。

局限性

  • 本研究为回顾性单中心设计,样本量和人群代表性有限。
  • 原文未报告其他局限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The incidence and imaging characteristics of non-neoplastic sulcal enhancement on contrast-enhanced T2-weighted fluid-attenuated inversion recovery (CE-T2FLAIR) imaging in routine neuro-oncologic magnetic resonance imaging (MRI) were investigated. Contrast-enhanced T1-T2FLAIR sequence matching was used to differentiate benign contrast leakage from leptomeningeal metastasis (LMS). This retrospective, single-center study included 337 patients who underwent contrast-enhanced brain MRI for evaluation of suspected intracranial metastasis. Sulcal enhancement on CE-T2FLAIR was classified as absent, contrast leakage, or LMS based on imaging and clinical criteria. Two neuroradiologists independently determined T1-T2FLAIR matching status. Overall, 271 showed no leptomeningeal enhancement; 55 patients demonstrated contrast leakage and were older than the other groups; 11 were accurately diagnosed with LMS. Using match positivity as the cutoff, sensitivity and specificity were 90.9% and 94.8%, respectively for the LMS diagnosis. Mismatch patterns were common in contrast leakage and associated with older age, higher cerebral microbleed burden, cortical superficial siderosis, and prior radiotherapy. Non-neoplastic sulcal enhancement on CE-T2FLAIR is a common finding in contemporary neuro-oncologic MRI, particularly with delayed post-contrast acquisition. Assessing agreement between CE-T2FLAIR and contrast-enhanced T1-weighted imaging provides a simple and robust method for distinguishing benign contrast leakage from LMS.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Joo, Lee, Yim, et al. When sulcal enhancement is not leptomeningeal metastasis: diagnostic value of T1-T2FLAIR matching for differentiating benign contrast leakage. Eur J Radiol. 2026. PMID: 42284969. doi:10.1016/j.ejrad.2026.112992

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。