文献速递乳腺US

小波频谱多通道网络降低BI-RADS 4a及以上乳腺肿瘤活检率

Wavelet Spectrum in a Multi-Channel Network May Reduce Biopsy Rates on Diagnosis of Breast Tumors With BI-RADS Category 4a or Higher.
PubMed 文献 · J Ultrasound Med · 2026-06-11

针对BI-RADS 4a及以上乳腺肿瘤,回顾性纳入390例患者,构建整合B模式、高频13 MHz与低频7 MHz小波分量的三通道超声图像,采用双通道深度学习网络进行良恶性分类。结果显示整体准确率为84.52%,在最严格阈值下患者特异性评估的免活检率为26.01%,漏诊率为1.786%。

要点

  • 小波频谱特征结合深度学习较单纯B模式图像分类性能平均提升2%
  • 最严格阈值下免活检率26.01%、漏诊率1.786%,可作为减少不必要活检的辅助工具
  • 患者特异性评估框架更贴近临床实际,免活检与漏诊率比值在各阈值下保持较高

核心结论

  • 将小波频谱分析整合入多通道深度学习网络可有效改善BI-RADS 4a及以上乳腺肿瘤的良恶性分类
  • 该方法作为无创辅助工具具有提升诊断精度并减少不必要活检的显著潜力

研究设计与样本

  • 回顾性研究,纳入390例BI-RADS 4a及以上乳腺病变患者
  • 构建由B模式、高频13 MHz与低频7 MHz小波分量组成的三通道超声图像,经双通道深度学习网络处理
  • 建立并评估严格的患者特异性免活检标准

关键影像表现/征象

  • 利用B模式、高频13 MHz与低频7 MHz小波分量构建三通道超声图像用于肿瘤分类

诊断标准与关键数值

  • 整体准确率为84.52%
  • 最严格阈值下患者特异性评估框架的免活检率为26.01%,漏诊率为1.786%
  • 较单纯使用B模式图像,整合小波频谱特征使肿瘤分类性能平均提升2%
  • 免活检率与漏诊率比值在各阈值下均保持较高

临床应用与阅片要点

  • 该计算机辅助诊断方法可用于BI-RADS 4a及以上乳腺肿瘤的无创良恶性分类
  • 在临床最严格阈值下可减少约四分之一的活检且漏诊率低于2%
  • 采用患者特异性评估标准更符合临床实际应用场景

局限性

  • 研究为回顾性设计

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: BI-RADS 4a+ breast tumors have a high rate of unnecessary biopsies due to ambiguous diagnostic features. This study aims to develop and evaluate a computer-aided diagnosis method integrating wavelet spectrum analysis with deep learning for benign-malignant classification of these tumors, so as to reduce unnecessary invasive biopsies.

METHODS: A retrospective study was conducted on 390 patients with breast lesions categorized as BI-RADS 4a or higher. We proposed a computerized diagnostic method that combines wavelet spectrum analysis with deep learning. A 3-channel ultrasound image was constructed by integrating B-mode, high-frequency (13 MHz), and low-frequency (7 MHz) wavelet components. This multi-channel input was processed by a dual-channel deep learning network for tumor classification. A strict patient-specific biopsy-sparing criterion was also established and evaluated.

RESULTS: The integration of wavelet spectral features improved tumor classification performance by an average of 2% compared to using B-mode images alone. The proposed model achieved an overall accuracy of 84.52%. Under a patient-specific evaluation framework more aligned with clinical practice, the model demonstrated a biopsy-sparing rate of 26.01% while maintaining a low missed diagnosis rate of 1.786% at the most stringent threshold. The biopsy-sparing to missed diagnosis rate ratio remained high across thresholds, confirming the robustness of the patient-based assessment.

CONCLUSION: The integration of wavelet spectrum analysis into a multi-channel deep learning network effectively improves the classification of BI-RADS 4a or higher breast tumors. This method demonstrates significant potential as a non-invasive adjunct tool to enhance diagnostic precision and reduce unnecessary biopsies in clinical practice.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Li, Han, Qi, et al. Wavelet Spectrum in a Multi-Channel Network May Reduce Biopsy Rates on Diagnosis of Breast Tumors With BI-RADS Category 4a or Higher. J Ultrasound Med. 2026. PMID: 42273765. doi:10.1002/jum.70315

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。