文献速递妇产影像技术与安全US

前穹窿/宫颈区定量血流与胎盘植入及术中出血的关系

Association of quantitative vascularization of the anterior fornix/cervix region with placenta accreta spectrum and associated intraoperative hemorrhage.
PubMed 文献 · Ultrasound Obstet Gynecol · 2026-10-25

本研究前瞻性纳入117例前置胎盘疑诊PAS孕妇,经阴道彩色多普勒评估前穹窿/宫颈区定量血管化(QV)。以组织病理为参考标准,结果显示QV可区分PAS与非PAS(AUC 0.821),最佳阈值8.5%对应敏感度70.5%、特异度89.7%,且QV≥8.5%与穿透性胎盘、严重术中失血及大量输血相关。

要点

  • QV≥8.5%时提示PAS风险明显升高,阳性预测值93.9%,但阴性预测值仅50.0%,不能单独用于排除PAS。
  • QV≥8.5%与严重术中失血(>1500 mL)及需输≥4单位血制品相关,可用于术前风险分层。
  • QV测量需在标准化设置的经阴道彩色多普勒下,于正中矢状面采集前穹窿/宫颈区动态视频逐帧计算彩色像素占比。

核心结论

  • 前穹窿/宫颈区QV≥8.5%可识别PAS风险增高及严重术中失血风险增高的患者,可用于支持临床管理和手术规划。
  • QV区分PAS与非PAS的AUC为0.821(95% CI 0.739-0.886),提示该定量指标具有中等偏上的判别能力。
  • QV≥8.5%与PAS(OR 14.9,95% CI 4.7-47.0)、穿透性胎盘(OR 55.5,95% CI 10.1-305.7)、严重IOBL(OR 3.9,95% CI 1.8-8.7)及输≥4单位血制品(OR 4.6,95% CI 2.0-10.4)均显著相关。

研究设计与样本

  • 经阴道超声采用标准化彩色多普勒设置,在正中矢状面显示宫颈与子宫下段,采集前穹窿/宫颈区动态视频进行后处理分析。
  • 参考标准为组织病理学确认的PAS及其植入深度,其中PAS组89例(76.1%),包括粘连性11例、植入性55例、穿透性23例。
  • QV分析时将前穹窿/宫颈区定义为感兴趣区,逐帧计算该区域内彩色像素百分比,取所有帧的平均值为QV值,且未告知临床医生、未用于临床决策。
  • 严重术中失血(IOBL)定义为>1500 mL,共109例获得可靠失血量估计,其中53例(48.6%)发生严重IOBL。

关键影像表现/征象

  • 对疑诊PAS的前置胎盘孕妇行经阴道彩色多普勒检查时,前穹窿/宫颈区可见异常增多的彩色血流信号,表现为区域彩色像素占比升高。
  • 该研究中PAS高危的产前超声特征包括子宫胎盘界面消失、胎盘陷窝、胎盘后方血流增多及膀胱壁异常,据此确定临床高风险。
  • QV作为动态视频逐帧量化指标,反映前穹窿/宫颈区血流随时间变化的平均充盈程度,而非单帧静态图像的主观分级。

诊断标准与关键数值

  • QV区分组织病理确认PAS与非PAS的AUC为0.821(95% CI 0.739-0.886)。
  • QV最佳阈值为8.5%,对应敏感度70.5%(95% CI 59.8-79.7%)、特异度89.7%(95% CI 68.3-96.1%)。
  • QV≥8.5%的阳性预测值为93.9%(95% CI 86.1-97.5%),阴性预测值为50.0%(95% CI 40.3-57.8%)。
  • QV≥8.5%与PAS的OR为14.9(95% CI 4.7-47.0,P<0.0001),与穿透性胎盘的OR为55.5(95% CI 10.1-305.7,P<0.0001)。
  • QV≥8.5%与严重IOBL的OR为3.9(95% CI 1.8-8.7,P=0.0009),与需输≥4单位血制品的OR为4.6(95% CI 2.0-10.4,P=0.0002)。

临床应用与阅片要点

  • 在日常报告中,当经阴道彩色多普勒观察到前穹窿/宫颈区血流信号明显增多时,可提示进一步测量QV以辅助PAS风险分层。
  • QV测量依赖标准化彩色多普勒参数与正中矢状面动态视频采集,不同设备或设置间不宜直接套用8.5%阈值。
  • QV阴性预测值有限,QV<8.5%不能排除PAS,应结合子宫胎盘界面、陷窝、膀胱壁等常规征象综合判断。
  • 对QV≥8.5%的病例,术前应预判严重失血及大量输血可能,并据此协调血库、介入及多学科手术团队资源。

局限性

  • 该研究为单中心设计,结果的外部推广性可能受限。
  • 研究者指出QV的阴性预测值有限,限制了其作为排除PAS的独立工具。
  • QV测量依赖标准化彩色多普勒设置与视频后处理流程,操作者及设备差异可能影响可重复性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: We aimed to evaluate a quantitative method for analyzing vascularization in the anterior fornix/cervix (AFC) region in women at risk of placenta accreta spectrum (PAS). The primary aim was to evaluate the association between quantitative vascularization (QV) and severity of PAS (determined by histopathology) and to estimate the optimal QV cut-off value to predict PAS. A secondary aim was to evaluate the association of QV with severe intraoperative blood loss (IOBL).

METHODS: This was a prospective study including patients with anterior placenta previa referred for suspected PAS at the University of Texas Health Science Center at Houston, TX, USA, between December 2021 and June 2025. Transvaginal ultrasound with color Doppler (with standardized settings) was performed to visualize the cervix and the lower uterine segment in the midsagittal plane. The prenatal diagnosis of high risk for PAS was based on ultrasound features including loss of the uteroplacental interface, the presence of placental lacunae, increased vascularization and abnormal bladder wall. For QV assessment, a videoclip was acquired, in which the AFC region was defined and post-processing analysis was used to estimate the percentage of color pixels within the AFC region in each frame. The mean value across all frames was defined as the QV value. QV values were not provided to clinicians and were not used for clinical decisions. Associations between QV and PAS, depth of implantation, IOBL and units of blood products transfused were evaluated, as well as the ability of QV to discriminate between patients with and those without PAS.

RESULTS: A total of 117 patients were included. PAS was confirmed histopathologically in 89 (76.1%) patients (placenta accreta, n = 11; placenta increta, n = 55; placenta percreta, n = 23). A reliable estimation of IOBL was obtained in 109 patients and severe IOBL (> 1500 mL) occurred in 53 (48.6%) of these cases. The area under the receiver-operating-characteristics curve, demonstrating the ability of QV to discriminate between cases with and those without confirmed PAS, was 0.821 (95% CI, 0.739-0.886). The optimal QV cut-off value was 8.5%, yielding a sensitivity of 70.5% (95% CI, 59.8-79.7%), specificity of 89.7% (95% CI, 68.3-96.1%), positive predictive value of 93.9% (95% CI, 86.1-97.5%) and negative predictive value of 50.0% (95% CI, 40.3-57.8%). QV ≥ 8.5% was associated with increased odds of PAS (odds ratio (OR), 14.9 (95% CI, 4.7-47.0); P < 0.0001), placenta percreta (OR, 55.5 (95% CI, 10.1-305.7); P < 0.0001), severe IOBL (OR, 3.9 (95% CI, 1.8-8.7); P = 0.0009) and the need for ≥ 4 units of blood products during delivery (OR, 4.6 (95% CI, 2.0-10.4); P = 0.0002).

CONCLUSION: QV ≥ 8.5% of the AVC region identifies patients at increased risk for PAS and for severe IOBL. Although the negative predictive value was limited, QV assessment of the AFC region may provide valuable information to support clinical management and surgical planning in PAS. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Kassir, Hernandez-Andrade, Gerulewicz-Vannini, et al. Association of quantitative vascularization of the anterior fornix/cervix region with placenta accreta spectrum and associated intraoperative hemorrhage. Ultrasound Obstet Gynecol. 2026. PMID: 42927468. doi:10.1002/uog.70362

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。