文献速递神经外周血管技术与安全US

床旁超声瞳孔测量评估急性颈内动脉夹层瞳孔功能障碍

Point‐of‐Care Ultrasound for Quantitative Assessment of Pupillary Dysfunction in Acute Internal Carotid Artery Dissection
RSS 订阅 · Journal of Neuroimaging · 2026-09-29

该研究纳入33例急性颈内动脉夹层患者及年龄性别匹配的健康对照,使用超声瞳孔测量法量化评估患眼与健眼瞳孔直径和对光、睫状脊髓反射反应时间。结果显示超声瞳孔测量检出瞳孔异常率96.9%,而常规神经检查Horner综合征检出率39.4%。

要点

  • 超声瞳孔测量可量化检出急性颈内动脉夹层患者患眼瞳孔缩小及反射异常。
  • 超声瞳孔测量对瞳孔功能障碍的检出率高于常规神经检查。
  • 超声瞳孔测量可作为床旁神经超声辅助手段用于急诊颈内动脉夹层评估。

核心结论

  • 超声瞳孔测量是一种有前景的神经床旁超声应用,可客观、定量评估急性颈内动脉夹层患者的瞳孔功能障碍。
  • 超声瞳孔测量可作为常规神经检查的有价值补充,其对瞳孔异常的检出率明显高于临床Horner综合征检出。

研究设计与样本

  • 研究类型为前瞻性病例对照研究,纳入33例连续急性颈内动脉夹层患者,并匹配年龄和性别且无眼部病变的健康对照。
  • 超声检查由单一操作者完成,所有离线定量测量由对神经检查结果不知情的第二位研究者完成。

关键影像表现/征象

  • 患眼静息及直接和间接光刺激后瞳孔直径均明显小于健眼。
  • 患眼睫状脊髓反射所致散瞳幅度和散瞳时间均较健眼降低。

诊断标准与关键数值

  • 患眼与健眼静息及光刺激后瞳孔直径分别为3.23±0.64 mm和5.12±0.51 mm,p<0.01。
  • 患眼睫状脊髓反射散瞳幅度为4.03±2.8%,健眼为9.76±3.36%,p<0.01。
  • 患眼散瞳时间为2.984±0.278秒,健眼为2.071±0.223秒,p<0.01。
  • 超声瞳孔测量检出定量瞳孔异常率为96.9%,常规神经检查检出临床Horner综合征率为39.4%,p<0.01。

临床应用与阅片要点

  • 对可疑急性颈内动脉夹层患者,可将超声瞳孔测量作为床旁筛查辅助手段,重点比较双眼静息及光刺激后瞳孔直径。
  • Horner综合征临床不明显时,超声瞳孔测量发现的患眼瞳孔缩小及散瞳反射减弱可作为提示夹层的客观依据。

局限性

  • 本研究中超声检查由单一操作者完成,可能影响结果的可重复性和推广性。
英文原文(摘要)· 点击展开

ABSTRACT Background and Purpose Diagnosing internal carotid artery dissection (ICAD) can be challenging even for experienced clinicians, as one of its most specific signs—Horner syndrome (HS)—is often missed during routine neurological examination (NE). This study aimed to evaluate pupillary reactivity in ICAD patients using ultrasound pupillometry (UP) and compare quantitative UP findings with standard NE. Methods We enrolled 33 consecutive patients with acute ICAD and an age- and sex-matched healthy control group without ocular pathology. HS was assessed at admission using standard NE. UP was performed in both the affected eye (AE) and non-affected eye (NAE), measuring pupillary diameter (PD) and response time (PT) to light stimulus (LS) and ciliospinal reflex (CR). Ultrasound examinations were performed by a single operator, while all offline quantitative measurements were performed by a second investigator blinded to the neurological findings. Results UP revealed significantly smaller PDs in the AE compared with the NAE, both at rest and after direct and consensual LS (3.23 ± 0.64 mm vs. 5.12 ± 0.51 mm, p < 0.01). The AE also showed reduced CR response in terms of mydriasis (4.03 ± 2.8% vs. 9.76 ± 3.36%, p < 0.01) and dilation time (2.984 ± 0.278 s vs. 2.071 ± 0.223 s, p < 0.01). Similar differences were observed between the AE and controls. Quantitative pupillary abnormalities were identified by UP in 96.9% of patients, whereas clinical HS was detected by standard NE in 39.4% (p < 0.01). Conclusions UP represents a promising Neuro-POCUS application for the objective, quantitative assessment of pupillary dysfunction in acute ICAD and may serve as a valuable adjunct to routine NE.

来源:Journal of Neuroimaging,查看原文。版权归原作者所有。

引用

  1. Journal of Neuroimaging:Point‐of‐Care Ultrasound for Quantitative Assessment of Pupillary Dysfunction in Acute Internal Carotid Artery Dissection

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。