文献速递腹部CT

护士主导胃准备用于光子计数CT气体负性造影虚拟内镜成像

Nurse-Led Gastric Preparation for Gas-Negative-Contrast Volume-Rendered Three-Dimensional Virtual Endoscopy-Like Gastric Imaging on Photon-Counting CT: A Prospective Randomized Clinical Study
RSS 订阅 · Academic Radiology · 2026-10-21

本研究为单中心前瞻性随机试验,纳入120例接受腹部增强CT的患者,分四组评估不同产气粉剂量、CT平台及饮水辅助对胃准备的影像质量影响。结果显示6g产气粉在气体负性造影虚拟内镜成像中优于3g,光子计数CT在噪声、SNR、CNR及胃壁分层显示上优于能量积分探测器CT。

要点

  • 6g产气粉比3g更能获得满意胃扩张和气体负性造影虚拟内镜图像,但患者不适感更高。
  • 光子计数CT比能量积分探测器CT提供更低噪声和更好胃壁分层显示,有助于胃壁评估。
  • 饮水辅助可增加胃窦扩张评分,但不能改善气体负性造影虚拟内镜成像质量。

核心结论

  • 护士主导的光子计数CT胃准备可根据不同成像目的进行个体化调整。
  • 6g产气粉更适合气体负性造影虚拟内镜成像,3g可能足以满足常规胃评估。
  • 相同6g准备方案下光子计数CT较能量积分探测器CT噪声更低、SNR和CNR更高、胃壁分层显示更清晰。

研究设计与样本

  • 单中心前瞻性随机试验,纳入120例接受腹部增强CT的患者,按1:1:1:1分配至四组,每组30例。
  • 四组分别为PCCT-3g、PCCT-6g、EID-6g和PCCT-3g+W,所有准备均遵循护士标准化培训和护士主导五步准备方案。
  • 主要终点为气体负性造影虚拟内镜成像质量评分,次要终点包括胃内气/液体积、胃扩张程度、胃壁分层显示及定量图像指标。

关键影像表现/征象

  • PCCT-6g组胃内气体体积较PCCT-3g组增加201.85 cm³,胃扩张和气体负性造影虚拟内镜质量更优。
  • 光子计数CT噪声为5.37±0.72 HU,能量积分探测器CT噪声为10.90±1.98 HU,光子计数CT噪声更低。
  • 光子计数CT的SNR为12.56±1.92,CNR为18.89±4.16,均显著高于能量积分探测器CT的5.08±0.88和4.97±1.80。
  • 饮水辅助使PCCT-3g组胃内液体体积增加279.68 cm³,胃窦扩张评分增加2.13分,但未改善气体负性造影虚拟内镜质量。

诊断标准与关键数值

  • 6g产气粉相比3g在气体负性造影虚拟内镜成像质量上更高(P<0.001)。
  • 6g产气粉组不适感NRS评分为0.63±0.85,高于3g组的0.07±0.25。
  • 光子计数CT与能量积分探测器CT在相同6g产气粉剂量下胃扩张和气体负性造影虚拟内镜图像相当。
  • 光子计数CT的噪声、SNR、CNR及胃壁分层显示均优于能量积分探测器CT(P<0.001)。

临床应用与阅片要点

  • 行气体负性造影虚拟内镜成像时应优先选择6g产气粉剂量以获得更好的胃腔扩张和成像质量。
  • 常规胃评估时可考虑3g产气粉以减少患者不适,同时满足诊断需求。
  • 使用光子计数CT平台进行胃检查时,应充分利用其低噪声和高对比分辨优势评估胃壁分层。
  • 需要重点评估胃窦横断面时,可考虑饮水辅助准备以增加胃窦扩张度。

局限性

  • 本研究为单中心试验,样本量每组仅30例。
  • 6g产气粉组患者不适感评分高于3g组,舒适性与图像质量之间存在权衡。
  • 饮水辅助未能改善气体负性造影虚拟内镜成像质量,其临床应用价值有限。
英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate nurse-led gastric preparation for photon-counting computed tomography (PCCT)-based gas-negative-contrast volume-rendered (gas-VRT) virtual endoscopic gastric imaging, focusing on effervescent powder dose, PCCT-related image-quality advantages, and water-assisted preparation.

MATERIALS AND METHODS: This single-center prospective randomized trial enrolled 120 patients undergoing contrast-enhanced abdominal CT. Participants were allocated into four groups (n = 30 each): PCCT-3g, PCCT-6g, energy-integrating detector (EID)-6g, and PCCT-3g+W. All gastric preparations followed standardized nurse training and a nurse-led five-step preparation protocol, including patient instruction, protocol-specific gastric preparation, breath-holding guidance, positioning, and scan-timing control. The primary endpoint was the gas-VRT virtual endoscopy-like imaging quality score. Secondary endpoints included intragastric gas/liquid volume, overall and antral gastric distension, gastric wall layer visibility, quantitative image metrics, patient tolerance, and adverse events.

RESULTS: All patients finished examinations without severe adverse events. PCCT-6g achieved a larger intragastric gas volume than PCCT-3g, with an increase of 201.85 cm³, superior gastric distension and gas-VRT quality (all P < 0.001), accompanied by higher discomfort (numeric rating scale score, 0.63 ± 0.85 vs 0.07 ± 0.25). At an identical 6 g effervescent dose, PCCT and EID-CT yielded comparable distension and gas-VRT images; PCCT provided lower noise (5.37 ± 0.72 HU vs 10.90 ± 1.98 HU) and improved signal-to-noise ratio (SNR) (12.56 ± 1.92 vs 5.08 ± 0.88), contrast-to-noise ratio (CNR) (18.89 ± 4.16 vs 4.97 ± 1.80), and wall layer visualization (all P < 0.001). Water supplementation increased intragastric liquid volume by 279.68 cm³ and antral distension score by 2.13 points in the PCCT-3g group, but failed to enhance gas-VRT quality.

CONCLUSION: Nurse-led PCCT gastric preparation can be customized for different imaging objectives. Six grams of effervescent powder is preferable for gas-VRT virtual endoscopic imaging, while 3 g may be sufficient for routine gastric evaluation. Under the same 6 g preparation protocol, PCCT provided lower image noise, higher SNR/CNR, and clearer gastric wall layer visualization than EID-CT, suggesting platform-specific value beyond gastric distension alone. Water assistance may benefits antral cross-sectional assessment but did not improve gas-VRT imaging.

来源:Academic Radiology,查看原文。版权归原作者所有。

引用

  1. Academic Radiology:Nurse-Led Gastric Preparation for Gas-Negative-Contrast Volume-Rendered Three-Dimensional Virtual Endoscopy-Like Gastric Imaging on Photon-Counting CT: A Prospective Randomized Clinical Study
  2. Xiong, Liu, Jiang, et al. Nurse-Led Gastric Preparation for Gas-Negative-Contrast Volume-Rendered Three-Dimensional Virtual Endoscopy-Like Gastric Imaging on Photon-Counting CT: A Prospective Randomized Clinical Study. Acad Radiol. 2026. PMID: 42907267. doi:10.1016/j.acra.2026.09.051

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。