本研究回顾性分析一家儿科三级医疗中心2019—2026年间4例儿童移植肾活检后动静脉瘘的介入栓塞治疗。所有病例均经股动脉入路,采用两枚可解脱弹簧圈(锚定+填塞)实现瘘口闭塞,技术成功率100%,中位随访17个月无相关不良事件。

要点

  • 移植肾活检后动静脉瘘若持续存在或增大,可考虑介入栓塞处理。
  • 可解脱弹簧圈采用锚定+填塞组合可有效闭塞儿童移植肾AVF。
  • 术后影像随访显示闭塞效果持续,无轻微或严重不良事件。

核心结论

  • 可解脱弹簧圈栓塞是治疗儿童移植肾活检后动静脉瘘的可行方法,锚定+填塞组合在此小样本队列中可行且有效。

研究设计与样本

  • 回顾性研究,纳入2019—2026年一家儿科三级医疗中心行移植肾AVF栓塞术的4例患者。
  • 患者平均年龄15岁1个月,因病灶长期持续并在系列影像随访中增大而行栓塞治疗。

关键影像表现/征象

  • 栓塞适应证为系列影像显示病灶长期持续存在且体积增大。
  • 栓塞成功定义为病灶闭塞、早期静脉充盈消失且邻近实质血流改善。

诊断标准与关键数值

  • 技术成功定义为病灶闭塞、早期静脉充盈消失且邻近实质血流改善。
  • 4例均采用股动脉入路,使用两枚可解脱弹簧圈行锚定+填塞组合栓塞。
  • 技术成功率为100%,术后影像随访持续闭塞,平均随访17个月(范围2—36个月)。

临床应用与阅片要点

  • 术前可采用超声和CT进行栓塞路径规划。
  • 术中观察病灶闭塞及早期静脉充盈消失是确认技术成功的关键征象。

局限性

  • 本研究样本量小,仅为4例。
  • 本研究为回顾性设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: Ultrasound (US)-guided transplant kidney biopsy is required to exclude rejection or other causes of allograft dysfunction. Arteriovenous fistula (AVF) is a known complication, with occurrence rates from 1.5% to 18%. AVF may heal spontaneously; however, persistent lesions may result in hypertension, renal impairment, or hematuria. The purpose of the present study was to investigate the technical details and outcomes of postbiopsy kidney transplant AVF in children, treated by interventional radiology.

MATERIALS AND METHODS: This was a retrospective review (2019-2026) of renal transplant AVF embolization procedures in a pediatric tertiary care center. Clinical details, including transplant history, biopsy, AVF diagnosis, embolization procedural details, and postembolization clinical course, were collected. Technical success was defined as occlusion of the lesion with cessation of early venous filling, and improved flow to the adjacent parenchyma.

RESULTS: Four cases were identified, with a mean age of 15 years 1 month. Embolization was indicated due to long-term persistence and increasing lesion size on serial imaging. US and computed tomography (CT) were used for procedural planning. In all cases, a femoral arterial access approach was used, with a combination of two detachable coils (anchoring and packing), obtaining AVF occlusion. A 100% technical success rate was achieved. This has persisted in postprocedure imaging follow-up (mean follow-up: 17 months [2-36]). No minor or major adverse events were observed.

CONCLUSION: This study illustrates that embolization with detachable coils is a viable option to treat postbiopsy kidney transplant AVF in children. An anchoring and packing coil combination was feasible and effective in this small cohort.