文献速递妇产影像技术与安全US

经阴道超声诊断深部子宫内膜异位症:SRU共识标准的前瞻性验证及间接征象价值

Transvaginal ultrasound for deep endometriosis: Prospective validation of SRU criteria and diagnostic value of indirect signs.
PubMed 文献 · Eur J Radiol · 2026-01-28

本研究前瞻性纳入288例临床怀疑深部子宫内膜异位症的经阴道超声检查,以手术所见为参考标准,评估SRU共识标准及间接征象的诊断效能。结果显示TVUS总体准确率84.4%(敏感度87.4%,特异性76.8%),子宫固定后屈、肠管牵拉、卵巢固定等间接征象与特定部位病变显著相关,有助于术前定位和规划。

要点

  • 子宫固定后屈:提示肠管、直肠阴道隔及子宫浆膜受累风险
  • 肠管牵拉征:预测肠管、直肠阴道隔、子宫浆膜及阴道病变的独立征象
  • 卵巢固定或位置异常:高度提示同侧卵巢子宫内膜异位症及宫骶韧带受累

核心结论

  • 基于SRU共识的TVUS对深部子宫内膜异位症具有良好的诊断准确性(准确率84.4%,敏感度87.4%,特异性76.8%)
  • 间接征象(子宫固定后屈、肠管牵拉、卵巢固定)有助于病灶定位,改善术前规划

研究设计与样本

  • 前瞻性研究,单中心(青岛大学附属医院),纳入2024年5月至2025年4月临床怀疑深部子宫内膜异位症的288例患者
  • 经阴道超声结果与手术所见逐一对比,采用多变量logistic回归分析间接征象与病灶位置的关系
  • 参考标准:手术所见(含病理,但原文未明确说明病理细节)

关键影像表现/征象

  • 子宫固定后屈:与肠管受累(OR 2.07)、直肠阴道隔受累(OR 2.83)、子宫浆膜受累(OR 2.38)显著相关
  • 肠管牵拉:预测肠管(OR 6.45)、直肠阴道隔(OR 4.53)、子宫浆膜(OR 2.15)、阴道(OR 3.83)受累
  • 同侧卵巢固定或位置异常:提示同侧卵巢子宫内膜异位症(右侧OR 16.9,左侧OR 14.54)及宫骶韧带受累(右侧OR 4.38,左侧OR 2.23)
  • 文献未单独列出各征象的敏感度/特异性数值,仅给出OR值

诊断标准与关键数值

  • TVUS诊断深部子宫内膜异位症总体:敏感度87.4%,特异性76.8%,准确率84.4%(以手术所见为参考标准)
  • 间接征象的阳性预测价值以OR值量化,未见诊断阈值或分级标准

临床应用与阅片要点

  • 阅片时注意评估子宫位置、肠管活动度及卵巢位置,发现固定后屈或牵拉征象需警惕深部内膜异位灶
  • 卵巢固定或位置异常应高度提示同侧内膜异位,报告时建议明确具体侧别
  • 间接征象可用于补充直接病灶显示,提高术前定位信心,但应结合直接征象综合判断

局限性

  • 单中心研究,样本量288例,可能影响外推性
  • 原文未提及手术者与超声阅片者之间的盲法情况
  • 未报告不同部位病变的独立敏感度/特异性数值

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The SRU consensus on pelvic ultrasound proposed standardized augmented ultrasound, but its validity and indirect signs' role require validation. This study will explore the application value of this consensus in deep endometriosis.

METHOD: This prospective study enrolled patients with clinically suspected endometriosis at Qingdao University Affiliated Hospital from May 2024 to April 2025. TVUS findings were compared with surgical findings. The diagnostic performance of TVUS for endometriosis was calculated, and multivariable logistic regression was applied to analyze associations between indirect sonographic signs and lesion locations.

RESULTS: Included were 288 patients with clinical suspicion of DE. For DE detection, TVUS showed an overall accuracy of 84.4% (sensitivity 87.4%, specificity 76.8%). Fixed uterine retroflexion was significantly associated with bowel (OR 2.07, 95% CI 1.16-3.71), RVS (OR 2.83, 95% CI 1.34-6.32), and uterine serosal involvement (OR 2.38, 95% CI 1.19-4.88). Bowel tethering predicted bowel (OR 6.45, 95% CI 3.69-11.53), RVS (OR 4.53, 95% CI 2.24-9.62), uterine serosal (OR 2.15, 95% CI 1.12-4.18), and vaginal lesions (OR 3.83, 95% CI 1.85-8.25). Ipsilateral ovarian fixation or abnormal position was indicative of ipsilateral ovarian endometriosis (right: OR 16.9, 95% CI 9.15-32.96; left: OR 14.54, 95% CI 8.02-27.63) and USL involvement (right: OR 4.38, 95% CI 2.40-8.29, left: OR 2.23, 95%CI 1.3-3.91).

CONCLUSION: SRU-based ultrasound demonstrates high diagnostic accuracy for DE. Indirect signs effectively localize endometriotic lesions, enhancing surgical planning.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Hu, Wang, Meng, et al. Transvaginal ultrasound for deep endometriosis: Prospective validation of SRU criteria and diagnostic value of indirect signs. Eur J Radiol. 2026. PMID: 41619574. doi:10.1016/j.ejrad.2026.112702

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。