相关性加权平均改善肝脏DWI质量:左叶获益显著
前瞻性纳入103例接受肝脏MRI的受试者,对比原始数据重建的DWI与相关性加权平均因子校正后的DWI。结果显示CWAF可改善左叶肝脏边缘锐利度和病灶显著性,但整体图像质量略降低;ADC值在CWAF重建中普遍低于原始重建。
要点
- 左叶病灶在DWICWAF上显示更清晰,左叶病变测量优先参考CWAF重建图像。
- CWAF重建的肝实质和病灶信号强度比普遍更高,阅片时注意信号对比变化。
- CWAF重建ADC值总体偏低,随访或阈值判断时需注意序列重建方式的一致性。
核心结论
- CWAF可改善左叶肝脏边缘锐利度和病灶显著性,但整体图像质量较原始DWI略有下降。
- DWICWAF的肝实质及病灶ADC值总体低于DWIOriginal,左叶病灶ADC值与原始重建无显著差异。
研究设计与样本
- 前瞻性研究,纳入103例接受肝脏MRI的受试者,DWI分别用原始数据和CWAF校正数据重建。
- 两名放射科医师独立采用五分制量表评价高b值DWI图像质量、噪声、左右叶肝脏边缘锐利度及病灶显著性。
- 在四个肝段及肝脏病灶中测量信号强度比和ADC值,病灶按左叶和右叶分别分析。
关键影像表现/征象
- DWICWAF的左叶肝脏边缘锐利度评分优于DWIOriginal(P < 0.001)。
- DWICWAF的左叶病灶显著性评分优于DWIOriginal(P < 0.001)。
- DWIOriginal的整体图像质量评分、噪声评分及右叶肝脏边缘锐利度评分高于DWICWAF。
- 全部肝段中DWICWAF的肝脏信号强度比均高于DWIOriginal(P < 0.007)。
- 全部肝段中DWICWAF的肝脏ADC值均低于DWIOriginal(P < 0.001)。
诊断标准与关键数值
- 左右叶肝脏边缘锐利度、整体图像质量、图像噪声及病灶显著性均采用五分制量表评价。
- 右叶病灶ADC值在DWICWAF中低于DWIOriginal(P < 0.001),左叶病灶ADC值差异不显著(P = 0.48)。
- 病灶信号强度比在全部肝段中均表现为DWICWAF高于DWIOriginal(P < 0.007)。
临床应用与阅片要点
- 左叶病灶的检出和定性可优先参考CWAF重建的DWI图像。
- 右叶图像质量在原始DWI中整体更优,右叶病变阅片可继续以DWIOriginal为主。
- 使用ADC值诊断或比较时应注明重建方式,避免与历史数据或不同重建方法直接混淆。
局限性
- 原文未报告样本量外部的多中心验证或外部可推广性限制。
- 研究为前瞻性设计但未报告随机化或盲法的具体实施方式。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the feasibility of correlation-weighted averaging factor (CWAF) in liver diffusion-weighted imaging (DWI).
MATERIALS AND METHODS: This prospective study included 103 participants who underwent liver MRI. DWI were reconstructed using both original data (DWIOriginal) and CWAF-corrected data (DWICWAF). Two radiologists independently assessed high-b DWI images for overall image quality, image noise, hepatic edge sharpness, and lesion conspicuity in the right and left lobes using five-point scales. Signal intensity ratio (SIR) and apparent diffusion coefficient (ADC) values were measured in four hepatic segments and in liver lesions, with lesion measurements analyzed separately for each lobe. These parameters were compared between the two image sets.
RESULTS: The scores for overall image quality (P < 0.001), image noise (P < 0.001), and hepatic edge sharpness in the right lobe (P = 0.001) were higher in DWIOriginal compared with DWICWAF. In contrast, hepatic edge sharpness (P < 0.001) and lesion conspicuity (P < 0.001) in the left lobe were superior in DWICWAF. Liver and lesion SIRs were higher in DWICWAF across all segments than in DWIOriginal (P < 0.007). Liver ADC values were lower in DWICWAF than in DWIOriginal in all segments (P < 0.001). Lesion ADC values were also lower in DWICWAF than in DWIOriginal in the right lobe (P < 0.001) but were not different in the left lobe (P = 0.48).
CONCLUSION: CWAF improved hepatic edge sharpness and lesion conspicuity in the left lobe, although overall image quality was slightly reduced. ADC values were generally lower in DWICWAF than in DWIOriginal.
引用
- Kaga, Noda, Asano, et al. Enhancing liver diffusion-weighted imaging quality with correlation-weighted averaging: notable benefits in the left hepatic lobe. Eur J Radiol. 2026. PMID: 41604787. doi:10.1016/j.ejrad.2026.112680
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。