本研究系统综述了术前CT和MRI影像组学模型对结直肠癌肝转移的诊断效能,纳入20项研究共3765例患者。18项研究进入定量Meta分析,预测异时性转移的合并AUC为0.83,检测同时性转移的合并AUC为0.85。研究存在显著发表偏倚和方法学弱点,结果可能被高估。

要点

  • 术前影像组学预测异时性肝转移合并AUC为0.83,存在显著发表偏倚,实际效能可能更低
  • 术前影像组学检测同时性肝转移合并AUC为0.85,研究间异质性中等至较大
  • 影像组学质量评分平均约48%,方法学不完善,临床转化前需多国验证

核心结论

  • 影像组学有潜力预测异时性肝转移和检测同时性肝转移,但现有证据受方法学弱点、地域偏倚和发表偏倚限制

研究设计与样本

  • 系统综述与Meta分析,遵循PRISMA 2020指南,系统检索主要数据库至2025年7月
  • 纳入20项研究共3765例结直肠癌患者,18项研究进入定量Meta分析
  • 采用双变量随机效应模型分别对预测异时性转移和同时性转移进行分析
  • 质量评估采用影像组学质量评分和QUADAS-2,由独立人员完成
  • 基于术前CT和MRI的影像组学模型,以肝转移为参考标准

诊断标准与关键数值

  • 预测异时性转移的合并AUC为0.83,95% CI为0.73至0.90
  • 检测同时性转移的合并AUC为0.85,95% CI为0.76至0.91
  • 异质性为中等至较大,预测模型存在显著发表偏倚,Deeks检验P<0.001
  • 平均影像组学质量评分约为48%

临床应用与阅片要点

  • 预测异时性转移模型的发表偏倚为显著水平,实际诊断效能可能低于报告的合并AUC
  • 检测同时性转移的模型表现略优于异时性预测,AUC为0.85
  • 当前影像组学模型在结直肠癌肝转移临床应用前需进行多国验证

局限性

  • 存在显著发表偏倚,尤其预后模型Deeks检验P<0.001,合并估计值可能被乐观夸大
  • 方法学质量不理想,平均影像组学质量评分约48%
  • 存在地域偏倚,尚缺乏跨国验证

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate the diagnostic performance of preoperative computed tomography (CT) and magnetic resonance imaging (MRI)-based radiomics models in detecting liver metastases in patients with colorectal cancer (CRC).

MATERIALS AND METHODS: Following PRISMA 2020 guidelines, we systematically searched major databases up to July 2025. Study selection, data extraction, and quality assessment (Radiomics Quality Score and QUADAS-2) were performed independently. Separate bivariate random-effects meta-analyses were conducted for prognostic (metachronous) and diagnostic (synchronous) predictions.

RESULTS: Twenty studies (3765 patients) were included in the systematic review. Twenty studies were included in the systematic review. Of these, 18 studies were included in the quantitative meta-analysis. For predicting metachronous metastases (13 studies), the pooled AUC was 0.83 (95% CI: 0.73-0.90), although significant publication bias suggested that this estimate may be optimistically inflated. For the detection of synchronous metastases (five studies), the pooled AUC was 0.85 (95% CI: 0.76-0.91). Heterogeneity was moderate to substantial. However, significant publication bias was detected for prognostic models (Deeks' test, P < 0.001), suggesting that these pooled estimates may be optimistically inflated.

CONCLUSION: Radiomics has the potential to predict metachronous and detect synchronous liver metastases in CRC. However, methodological weaknesses (mean Radiomics Quality Score ∼48%), geographic bias, and publication bias limit this evidence. Multinational validation is required before clinical application of the findings.