文献速递妇产影像儿科影像外周血管US

高分辨率血流渲染与STIC诊断胎儿腹主动脉-肝动脉-脐静脉瘘

Prenatal Diagnosis of Abdominal Aorta-Hepatic Artery-Umbilical Vein Fistula Using High-Definition Flow Render Mode and Spatiotemporal Image Correlation.
PubMed 文献 · J Ultrasound Med · 2026-01-24

本研究评估高分辨率血流渲染模式联合时间空间相关成像技术诊断胎儿腹主动脉-肝动脉-脐静脉瘘的价值,纳入6例病例分析。瘘管连接腹主动脉与脐静脉,6例均获得HD-flow渲染模式与STIC图像。该技术有助于更准确全面地观察瘘管血流动力学,早期诊断相关并发症并判断预后。

要点

  • HD-flow渲染模式联合STIC可显示腹主动脉与脐静脉之间的瘘管连接。
  • 瘘管直径>3 mm者更容易合并心外结构异常和先天性心脏缺陷。
  • 瘘管直径/脐静脉直径>0.65或瘘管直径/腹主动脉直径>0.9时心力衰竭发生率更高。

核心结论

  • HD-flow渲染模式联合STIC有助于更准确全面地观察胎儿腹主动脉-肝动脉-脐静脉瘘的血流动力学,利于早期诊断相关并发症并判断预后。

研究设计与样本

  • 病例分析研究,共纳入6例胎儿腹主动脉-肝动脉-脐静脉瘘。
  • 使用高分辨率血流渲染模式和时间空间相关成像技术进行产前超声评估。
  • 产后结局评估在本医疗机构内完成。

关键影像表现/征象

  • 瘘管在腹主动脉与脐静脉之间形成连接。
  • 6例均成功获取HD-flow渲染模式图像及STIC图像。
  • 3例瘘管直径>3 mm的胎儿合并心外结构异常和先天性心脏缺陷。

诊断标准与关键数值

  • 瘘管直径/脐静脉直径比值>0.65时心力衰竭发生率更高。
  • 瘘管直径/腹主动脉直径比值>0.9时心力衰竭发生率更高。
  • 3例胎儿存活,3例胎儿死亡,其中1例宫内死亡。

临床应用与阅片要点

  • 产前超声检查可疑腹部血管畸形时,应尝试获取HD-flow渲染模式及STIC图像以显示瘘管全程连接关系。
  • 测量瘘管直径、脐静脉直径及腹主动脉直径并计算比值,有助于评估心力衰竭风险和预后。

局限性

  • 病例数较少,仅6例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Fetal abdominal aorta-hepatic artery-umbilical vein fistulas are rare congenital vascular-related malformations. This study aimed to assess the diagnostic efficacy of ultrasound in detecting fetal aorta-hepatic artery-umbilical vein fistulas using high-definition flow (HD-flow) render mode and spatiotemporal image correlation (STIC) technology. The study emphasizes six case analyses of abdominal aorta-hepatic artery-umbilical vein fistula using HD-flow render mode and STIC. Postnatal outcome evaluations were performed at our medical facility. The fistulas formed a connection between the abdominal aorta and the umbilical vein. HD-flow render mode and STIC were acquired in all six cases. In three cases, fistulas with a diameter >3 mm were associated with extracardiac structural abnormalities and congenital heart defects. The incidence of heart failure was higher when the ratio of the fistula diameter to the umbilical vein diameter was >0.65 and to the abdominal aorta diameter was >0.9. Three fetuses were viable to survive, while three did not, including one that died in utero. HD-flow render mode and STIC facilitate a more accurate and comprehensive observation of the hemodynamics of the fetal abdominal aorta-hepatic artery-umbilical vein fistula, enabling the early diagnosis of related complications and determination of prognosis.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Li, Lv, Zhang, et al. Prenatal Diagnosis of Abdominal Aorta-Hepatic Artery-Umbilical Vein Fistula Using High-Definition Flow Render Mode and Spatiotemporal Image Correlation. J Ultrasound Med. 2026. PMID: 41578858. doi:10.1002/jum.70158

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。