多模态超声评估小腿三头肌肌内静脉扩张与血栓
回顾性纳入142例受检者,其中肌内静脉扩张50例、肌内静脉血栓42例、健康对照50例,采用多模态超声评估小腿三头肌肌内静脉直径、肌肉厚度与硬度。结果显示血栓组腓肠肌内侧头及比目鱼肌厚度减小,关键指标联合模型鉴别血栓的AUC为0.934。多模态超声可作为筛查肌内静脉血栓高危人群的辅助工具。
要点
- 比目鱼肌剪切波速度在血栓组降低而扩张组升高,可用于鉴别肌内静脉血栓与扩张
- 联合腓肠肌内侧头静脉直径、比目鱼肌静脉直径、比目鱼肌剪切波速度及D-二聚体可提高血栓诊断效能
- 小腿三头肌厚度减低伴剪切波速度异常时需警惕肌内静脉血栓可能
核心结论
- 多模态超声可作为筛查肌内静脉血栓高危人群的有用辅助工具
- 联合超声参数与D-二聚体的模型鉴别肌内静脉血栓的AUC达0.934
研究设计与样本
- 回顾性研究,纳入142例接受下肢静脉超声检查者
- 分为肌内静脉扩张组50例、肌内静脉血栓组42例、健康对照组50例
- 采用多模态超声评价小腿三头肌肌内静脉直径、肌肉厚度及肌肉硬度
- 比较三组间超声参数与生化指标的差异
关键影像表现/征象
- 肌内静脉血栓组腓肠肌内侧头与比目鱼肌厚度低于扩张组和对照组
- 腓肠肌内侧头剪切波速度在血栓组低于对照组,血栓组与对照组分别为1.80 m/s与1.99 m/s
- 比目鱼肌剪切波速度在血栓组低于对照组,而扩张组高于对照组
诊断标准与关键数值
- 肌内静脉血栓组腓肠肌内侧头厚度为12.36 ± 2.95 mm,比目鱼肌厚度为15.35 ± 3.04 mm
- 扩张组比目鱼肌厚度为18.23 ± 3.04 mm,对照组为16.58 ± 2.93 mm
- 比目鱼肌剪切波速度血栓组为1.95 m/s,扩张组为3.10 m/s,对照组为2.67 m/s
- 腓肠肌内侧头静脉直径、比目鱼肌静脉直径、比目鱼肌剪切波速度及D-二聚体是影响肌内静脉血栓的关键因素
- 上述指标联合的logistic回归模型鉴别肌内静脉血栓的AUC为0.934,95% CI为0.888-0.972
临床应用与阅片要点
- 下肢静脉超声检查时可将小腿三头肌厚度及剪切波速度纳入测量,辅助识别肌内静脉血栓
- 比目鱼肌剪切波速度与肌肉厚度改变方向不同,有助于区分血栓与单纯肌内静脉扩张
- 对D-二聚体升高伴小腿肌肉超声参数异常者应提高肌内静脉血栓筛查意识
局限性
- 本研究为回顾性设计,可能存在选择性偏倚
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the applicability and diagnostic performance of multimodal ultrasound in assessing intramuscular venous disorders of the lower extremity.
METHODS: This retrospective study included 142 individuals who underwent lower-limb venous ultrasonography: 50 with intramuscular venous dilatation, 42 with intramuscular venous thrombosis (IMVT), and 50 healthy controls. Intramuscular vein diameter, muscle thickness, and muscle stiffness of the triceps surae were evaluated using multimodal ultrasonography. Ultrasound parameters and biochemical markers were compared among the three groups.
RESULTS: Compared with the dilatation (13.74 ± 3.00 mm, 18.23 ± 3.04 mm) and control groups (13.69 ± 2.71 mm, 16.58 ± 2.93 mm), the IMVT group exhibited reduced medial gastrocnemius (MG) and soleus muscle thicknesses (12.36 ± 2.95 mm and 15.35 ± 3.04 mm, respectively; p < 0.05). The dilatation group had greater soleus thickness than the control group (18.23 ± 3.04 vs. 16.58 ± 2.93 mm, p < 0.05). MG shear wave velocity (SWV) was lower in the IMVT group than in the control group (1.80 [1.69, 1.96] vs. 1.99 [1.74, 2.26] m/s, p < 0.05), whereas soleus SWV was lower in the IMVT group but higher in the dilatation group than in the control group (1.95 [1.75, 2.59] vs. 3.10 [2.19, 3.73] vs. 2.67 [2.14, 3.19] m/s; p < 0.05). MG vein diameter, soleus vein diameter, soleus SWV, and D-dimer levels were key factors influencing IMVT (p < 0.05). A logistic regression model combining these indicators achieved an area under the curve of 0.934 (95% CI: 0.888-0.972) for differentiating IMVT.
CONCLUSION: Multimodal ultrasound represents a useful adjunctive tool for screening individuals at high risk of IMVT.
引用
- Ultrasound in Medicine and Biology:Multimodal Ultrasound for Evaluating the Triceps Surae in Patients With Intramuscular Venous Dilatation and Intramuscular Venous Thrombosis of the Lower Extremity
- Dong, Qian, Zhang, et al. Multimodal Ultrasound for Evaluating the Triceps Surae in Patients With Intramuscular Venous Dilatation and Intramuscular Venous Thrombosis of the Lower Extremity. Ultrasound Med Biol. 2026. PMID: 42778441. doi:10.1016/j.ultrasmedbio.2026.08.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。