健康青年舌组织生物力学特性的区域差异与超声测量可靠性

Locoregional Variability and Measurement Reliability of Tongue Biomechanical Properties Assessed by Shear-Wave Elastography and Quantitative Ultrasound in Healthy Young Adults
RSS 订阅 · Ultrasound in Medicine and Biology · 2026-09-12

本横断面研究纳入86名健康青年,采用剪切波弹性成像和定量超声指标评估舌前、后区域的生物力学特性,并在矢状面和冠状面采集。结果显示舌后部硬度、回声强度和TSI指数更高,而衰减指数更低;矢状面采集的SWE、回声强度和衰减指数可靠性最高。

要点

  • 舌后部硬度、回声强度及TSI指数高于舌前部,衰减指数低于舌前部。
  • 矢状面采集的SWE、回声强度和衰减指数测量可靠性最佳。

核心结论

  • 定量超声显示健康青年舌组织生物力学特性存在固有的区域异质性。
  • 矢状面采集的剪切波弹性成像和回声强度提供最可靠的测量结果。
  • 该研究为未来临床人群舌生物力学研究提供方法学标准化依据和初步基准。

研究设计与样本

  • 横断面研究,共纳入86名健康青年,对舌前部和后部进行标准化超声评估。
  • 采用剪切波弹性成像测量组织硬度,定量超声参数包括回声强度、组织衰减成像指数和组织散射分布成像指数。
  • 在矢状面和冠状面两个成像平面采集测量数据。
  • 采用组内相关系数及95%置信区间、Bland-Altman分析和测量误差指标评价评定者内及评定者间可靠性。
  • 采用相关分析和多变量回归分析评估测量值与人体测量学变量的关联。

关键影像表现/征象

  • 舌后部在两个成像平面上均表现为更高硬度、更高回声强度和更高TSI指数。
  • 舌后部衰减指数低于舌前部。

诊断标准与关键数值

  • 舌前部与后部之间硬度、回声强度、TSI指数和衰减指数均存在显著区域差异。
  • 所有指标的评定者内可靠性为良好至优秀,重复测量间线性关联强。
  • 评定者间可靠性为中等到良好。
  • 矢状面采集的SWE、回声强度和衰减指数可靠性最高。

临床应用与阅片要点

  • 评价舌组织生物力学特性时推荐优先采用矢状面采集剪切波弹性成像和回声强度。
  • 阅片时需注意舌前部与后部固有的硬度、回声强度和衰减特性差异,避免将正常区域差异误判为病变。

局限性

  • 原文未报告研究设计的局限性。
英文原文(摘要)· 点击展开

OBJECTIVE: To characterize locoregional variability of tongue biomechanical properties using shear-wave elastography (SWE) and quantitative ultrasound markers and to evaluate intra- and inter-rater reliability in healthy young adults.

METHODS: In this cross-sectional study, 86 healthy young adults underwent standardized ultrasound assessment of anterior and posterior tongue regions. Tissue stiffness was measured using SWE. Quantitative ultrasound parameters included echo intensity (EI) and two acoustic attenuation markers (tissue attenuation imaging index and tissue scatter distribution imaging [TSI]). Measurements were acquired in sagittal and coronal imaging planes. Intra- and inter-rater reliability were evaluated using intra-class correlation coefficients with 95% confidence intervals, Bland-Altman analysis and measurement error metrics. Associations with anthropometric variables were evaluated using correlation and multivariable regression analyses. Locoregional differences between anterior and posterior tongue regions were analyzed.

RESULTS: Significant locoregional differences were observed between tongue regions. The posterior region demonstrated higher stiffness, EI and TSI index values across both planes, whereas attenuation index values were lower. Intra-rater reliability was good to excellent for all markers, with strong linear associations between repeated measures. Inter-rater reliability ranged from moderate to good. SWE, EI and attenuation index obtained in the sagittal plane demonstrated the highest reliability.

CONCLUSION: Quantitative ultrasound demonstrates intrinsic locoregional heterogeneity in tongue biomechanical properties in healthy young adults. SWE and EI in sagittal plane acquisitions provide the most reliable measurements. These findings support methodological standardization and provide preliminary methodological benchmarks for future investigations of tongue biomechanics in clinical populations.