青少年肺动脉直径与截面积MRI正常参考值
本研究回顾性纳入112例漏斗胸青少年,采用呼吸导航心电门控非增强3D bSSFP MRI于收缩期测量主肺动脉及左右肺动脉平均直径和截面积。结果显示BSA是肺动脉径线的独立预测因子,且与截面积相关性更强。研究提供了10-18岁青少年相应Z-score正常参考值。
要点
- BSA是肺动脉径线最强独立预测因子,日常报告中应结合体表面积评估肺动脉大小
- 肺动脉截面积与BSA相关性优于直径,可疑肺动脉异常时可加测截面积辅助判断
- 右肺动脉径线模型拟合略优于主肺动脉及左肺动脉,评估分支肺动脉时需分侧参考
核心结论
- 建立了10-18岁青少年主肺动脉及分支肺动脉平均直径与截面积的收缩期正常参考值及Z-score
- BSA是肺动脉径线的独立预测因子,与截面积的相关性较直径更强
- 年龄分组下肺动脉径线未呈单调递增,临床评估不应单独依赖年龄而应结合BSA
研究设计与样本
- 回顾性研究,纳入2023年1月至8月行心脏MRI的漏斗胸畸形患者112例
- 排除主动脉病变患者,使用呼吸导航心电门控非增强3D bSSFP序列收缩期成像
- 测量经多平面重建图像完成,采用加权线性回归评估血管径线与年龄、身高、BSA的关系
关键影像表现/征象
- 所有肺动脉径线均随身高和BSA呈正相关趋势,但与年龄分组间未显示单调递增关系
- 分支肺动脉尤其右肺动脉的径线模型拟合略优于主肺动脉
- 3D bSSFP多平面重建可清晰显示主肺动脉及左右分支肺动脉用于径线和截面积测量
诊断标准与关键数值
- 参考对象为10-18岁青少年,测量均基于收缩期呼吸导航心电门控非增强3D bSSFP序列
- BSA在全部模型中均为肺动脉径线的显著独立预测因子(p<0.01)
- 研究提供主肺动脉及左右分支肺动脉平均直径与截面积对应的Z-score正常参考值
临床应用与阅片要点
- 评估青少年肺动脉大小应优先参考BSA而非年龄,使用Z-score判断是否存在扩张或狭窄
- 报告青少年心脏MRI肺动脉径线时可对照本研究正常值,括号内标注Z-score更为规范
- 该技术为收缩期测量,与其他舒张期或全心动周期测量数值不可直接混用
局限性
- 研究对象均为漏斗胸畸形患者,漏斗胸本身可能对胸腔内血管形态产生影响
- 单中心回顾性设计,多数为男性,外推至其他人群时需谨慎
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The main pulmonary artery (MPA) and branch pulmonary arteries (PAs) are commonly affected in congenital heart diseases, with residual postoperative abnormalities, a leading cause of reintervention.
OBJECTIVE: To establish normative mean diameters, area and corresponding Z-scores for the MPA and branch PAs in teenagers, utilizing respiratory-navigated non-contrast ECG-gated 3D balanced steady-state free precession (3D bSSFP) magnetic resonance imaging (MRI) in systole.
MATERIALS AND METHODS: This retrospective study included patients with pectus excavatum deformity who underwent cardiac MRI between January and August 2023, excluding patients with aortopathies. Measurements of the PAs were obtained from non-contrast multiplanar reformatted 3D bSSFP datasets. Mean diameters and cross-sectional areas were calculated. Relationships between each vascular measurement and patient characteristics (age, height, and body surface area (BSA)) were assessed individually using weighted linear regression with inverse-density-based weights to account for data distribution. Additionally, Z-scores were calculated.
RESULTS: The study included 112 patients (91 males [81%]; mean age, 14.3±1.7 years; mean BSA, 1.63±0.2 m2). All vessel measurements showed a positive trend with body size (height and BSA). Across categorical age groups, however, they did not exhibit a monotonic increase with age. Across all models, BSA was a statistically significant independent predictor of PA dimensions (p<0.01), with stronger associations observed for cross-sectional area than for diameter. Height contributed minimally and was not an independent predictor. Branch PA measurements-particularly right pulmonary artery, and to a lesser extent left pulmonary artery-exhibited slightly better model fit than the MPA.
CONCLUSION: We report normative reference values for mean diameters and cross-sectional areas of the MPA and branch PAs in children 10-18 years, obtained using respiratory-navigated ECG-gated non-contrast-enhanced 3D bSSFP MRI technique in systole.
引用
- Kattainen, Morin, Wang, et al. Reference values for mean diameter and cross-sectional area of the pulmonary arteries in teenagers using ECG-gated 3D balanced steady‑state free precession MRI. Pediatr Radiol. 2026. PMID: 41575519. doi:10.1007/s00247-025-06500-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。