文献速递神经外周血管CT

皮层静脉HU值显影程度预测前循环急性缺血性卒中预后

Cortical vein opacification measurement using hounsfield unit values is a predictor for outcome in anterior circulation acute ischemic stroke.
PubMed 文献 · Eur J Radiol · 2026-01-13

本研究回顾性纳入143例24小时内前循环急性缺血性卒中患者,在CTA上测量Labbé静脉、蝶顶窦与Trolard静脉的HU值并计算患侧/对侧比值之和CVOR。结果显示CVOR与低灌注体积呈强负相关,且预测90天良好功能结局的AUC优于低灌注体积和缺血核心体积,是独立预测因子。

要点

  • CTA上皮层静脉HU比值之和CVOR越低,提示低灌注体积越大,预后越差。
  • CVOR预测90天良好mRS的AUC为0.784,优于低灌注体积0.711和缺血核心体积0.693。

核心结论

  • 以HU值评估的皮层静脉显影程度与低灌注体积呈强负相关(r=-0.759,P<0.001),与缺血核心体积呈中度负相关(r=-0.517,P<0.001)。

研究设计与样本

  • 回顾性研究,纳入2023年6月至2024年1月发病24小时内前循环急性缺血性卒中患者143例,平均年龄67.3±12.5岁,男性106例。

关键影像表现/征象

  • 在CTA上分别测量患侧与对侧Labbé静脉、蝶顶窦、Trolard静脉的HU值,计算各静脉rHU(患侧HU/对侧HU)后求和得CVOR。

诊断标准与关键数值

  • CVOR预测90天良好功能结局(mRS≤2)的AUC为0.784,与低灌注体积AUC 0.711比较P=0.008,与缺血核心体积AUC 0.693比较P=0.02。
  • 多因素分析校正混杂因素后CVOR为预后不良的独立预测因子,OR 0.06(0.02-0.32),P<0.001。

临床应用与阅片要点

  • 在急性前循环缺血性卒中CTA阅片时,可半定量比较患侧与对侧三条皮层静脉的HU比值,CVOR明显降低提示大低灌注负荷。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: In acute ischemic stroke (AIS) patients, the cortical vein opacification on computed tomographic angiography (CTA) imaging is usually asymmetric. We aimed to explore the correlation between CT perfusion parameters and cortical vein opacification evaluated by Hounsfield unit (HU) values, which is more accurately, and compare the predictive ability between them for outcome in AIS.

METHODS: Patients with AIS obtained within 24 h after onset from June 2023 to January 2024 were reviewed. Opacification of the cortical vein of Labbé, sphenoparietal sinus, and the Trolard vein was measured on CTA imaging using HU. Then HU ratio (rHU) was calculated by dividing the affected side by the controlateral side (rHU = HU-affected/HU-control). The sum of rHU of three cortical veins opacification (CVOR, CVOR = rHULabbé+ rHUsphenoparietal sinus + rHU Trolard vein) was calculated. The correlations between CVOR and CT perfusion parameters, hypoperfusion and ischemic core volume, were explored. Outcome was assessed at 90 days using the modified Rankin Scale (mRS), a standardized measure of disability ranging from 0 (no symptoms) to 6 (death). An mRS score of 2 or less is considered as functional outcome.

RESULTS: A total of 143 patients (mean age, 67.3 ± 12.5 years; 106 men) were included. We found that CVOR had a strong negative correlation with hypoperfusion volume (r = -0.759, P < 0.001) and had a moderate negative correlation with ischemic core volume (r = -0.517, P < 0.001). Receiver operating characteristic curve analysis revealed CVOR performed better than hypoperfusion volume (area under the curve [AUC], 0.784 vs 0.711; P = 0.008) and ischemic core volume (AUC, 0.784 vs 0.693; P = 0.02) in predicting the favorable 90-day mRS. Multivariable analysis showed CVOR was an independent predictor for poor outcome after adjusting for confounding factors [odds ratio 0.06 (0.02-0.32), p < 0.001].

CONCLUSION: Cortical vein opacification evaluated by HU values, had a strong negative correlation with hypoperfusion volume, and was also a novel independent predictor for clinical outcome.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Wang, Bian, Yang, et al. Cortical vein opacification measurement using hounsfield unit values is a predictor for outcome in anterior circulation acute ischemic stroke. Eur J Radiol. 2026. PMID: 41570717. doi:10.1016/j.ejrad.2026.112671

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。