经颅聚焦超声自适应定位与靶向优化数值研究

Adaptive Positioning and Targeting Optimization in Transcranial Focused Ultrasound (tFUS): A Numerical Study
RSS 订阅 · Ultrasound in Medicine and Biology · 2026-09-17

本研究采用数值模型优化经颅聚焦超声的探头定位与靶向策略。通过基于k空间的半径定位框架,在均质与异质性颅骨模型中评估声衰减及计算效率。结果显示该框架可提高计算资源利用效率,并实现参数驱动的自适应探头定位。

要点

  • 垂直靶区的传统刺激方式效果不足本方法的70%。
  • 异质性颅骨模型中平均衰减为81.92%±6.56%,高于均质模型的68.82%±7.22%。
  • k-RP优化框架可提升计算效率约40%。

核心结论

  • k-RP框架可提高计算资源利用效率并实现参数驱动的自适应探头定位。
  • 该框架为复杂环境中的神经调控研究提供方法学指导。

研究设计与样本

  • 研究类型为数值模拟研究。
  • 采用均质球形模型作为衰减参考,并在异质性颅骨模型中进行验证。
  • 使用伪谱法计算并识别峰值声压点作为定位点。

关键影像表现/征象

  • 异质性颅骨模型中均值衰减为81.92%±6.56%,均质介质中为68.82%±7.22%。
  • 较大换能器表现出更大的声束衰减和更多的热生成。
  • 2D与3D场景在均质介质中结果相似,可用2D数据预测3D结果。

诊断标准与关键数值

  • 垂直靶区的刺激方式效果低于本方法效果的70%。
  • k-RP框架提升计算效率约40%。
  • 均质介质中衰减为68.82%±7.22%,异质性颅骨中为81.92%±6.56%。

临床应用与阅片要点

  • 经颅聚焦超声定位应考虑颅骨异质性对声束衰减的影响。
  • 参数驱动的自适应探头定位有助于克服经验性调制策略的局限。

局限性

  • 异质性颅骨模型仅来自一名患者。
  • 研究为数值模拟,未经体内实验验证。
英文原文(摘要)· 点击展开

OBJECTIVE: Transcranial focused ultrasound (tFUS) has garnered significant attention owing to its capacity for precise depth penetration and high spatial resolution within tissues. However, the pronounced heterogeneity of the skull presents substantial challenges to precise targeting, limiting optimal therapeutic efficacy. Precise positioning is urgently needed.

METHODS: A homogeneous spherical model was employed as the attenuation reference. In the skull model, the transducer operating matrix was determined using a radius positioning method, and an acceleration factor was introduced to exclude invalid candidate locations within the matrix. Subsequently, pseudospectral method was applied to compute and identify peak acoustic pressure points, which served as positioning points.

RESULTS: The effect of the stimulation modality perpendicular to the target region, which was widely employed in previous studies, was found to be less than 70% of our effect. The results in both 2D and 3D scenarios exhibited similarities in a homogeneous medium, permitting the prediction of 3D outcomes from 2D data. In a heterogeneous skull model of one patient, the mean attenuation across all parameters (transducer diameter and ultrasound frequency) was 81.92% ± 6.56%, compared with 68.82% ± 7.22% in homogeneous medium. Larger transducers exhibited greater acoustic beam attenuation and increased heat generation. The proposed k-space-based radius positioning (k-RP) optimization framework improved computational efficiency by approximately 40%.

CONCLUSION: The k-RP framework proposed in this study improves the efficiency of computational resource utilization and enables parameter-driven adaptive probe positioning, thereby overcoming the limitations of traditional empirically based modulation strategies. This framework provides important methodological guidance for neuromodulation research in complex environments.