文献速递介入胸部DSA

胸导管结扎后持续乳糜胸的淋巴管造影表现与胸导管栓塞结局

Persistent Chylothorax despite Complete Thoracic Duct Ligation: Lymphangiographic Findings and Outcomes of Thoracic Duct Embolization
RSS 订阅 · Journal of Vascular and Interventional Radiology · 2026-09-20

本研究回顾性纳入40例因术后乳糜胸行胸导管结扎后仍持续漏乳糜并接受淋巴管造影及胸导管栓塞的患者。结果显示92.5%为结扎处完全闭塞,41%可见结扎下方对比剂渗漏,胸导管栓塞总体临床成功率为62.5%。术后第1天引流量与治疗有效显著相关,可用于指导后续处理。

要点

  • 胸导管结扎后持续乳糜胸时,应关注结扎下方淋巴损伤而非残留主干通路。
  • 术后第1天引流量明显下降者更可能治疗成功,可据此判断是否需辅助治疗。
  • 低引流量组拔管时间更短,提示基线引流量有助于预后分层。

核心结论

  • 胸导管结扎后持续乳糜胸患者中,胸导管多为完全结扎,持续漏多源于结扎下方淋巴损伤。
  • 胸导管栓塞总体临床成功率为62.5%,术后第1天引流量与治疗反应相关。

研究设计与样本

  • 回顾性队列研究,纳入2017年1月至2024年5月40例胸导管结扎后持续术后乳糜胸并行淋巴管造影及胸导管栓塞的患者。
  • 按栓塞前最大日引流量分为低流量组(≤1000mL/d)和高流量组(>1000mL/d)。
  • 临床成功定义为日引流量下降至少80%或一周内拔除引流管。

关键影像表现/征象

  • 淋巴管造影显示92.5%的患者存在胸导管完全结扎,表现为结扎处胸导管突然截断且无对比剂通过。
  • 在37例完全结扎患者中,41%可见结扎部位以下对比剂渗漏。
  • 胸导管或乳糜池插管成功率为95%。

诊断标准与关键数值

  • 胸导管栓塞总体临床成功率为62.5%(25/40)。
  • 成功组术后第1天引流量为324mL,未成功组为852mL,p=0.0003。
  • 低流量组拔管中位时间为7.5天,高流量组为14.5天,p=0.024。

临床应用与阅片要点

  • 对胸导管结扎后仍持续乳糜胸者,应优先观察结扎下方有无对比剂渗漏。
  • 术后第1天引流量下降不明显者,应考虑及时追加辅助干预。
  • 低引流量患者拔管更快,可作为日常报告预后提示。

局限性

  • 回顾性单中心研究。
  • 样本量为40例,未报告长期随访数据。
英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the lymphangiographic findings and clinical outcomes of thoracic duct embolization (TDE) in patients with persistent chyle leaks following complete thoracic duct ligation (TDL) for postsurgical chylothorax, and to identify factors associated with the treatment success MATERIALS AND METHODS: A retrospective review was conducted of 40 patients who underwent lymphangiography and TDE for persistent postoperative chyle leaks following TDL between January 2017 and May 2024. Patients were classified as low output (≤ 1000mL/day) or high output (> 1000mL/day) based on maximal daily drain output prior to TDE. Lymphangiographic findings, technical success, and clinical outcomes were analyzed. Clinical success was defined as an 80% or greater decrease in daily drain output or drain removal within one week.

RESULTS: Lymphangiography demonstrated complete TDL - defined as abrupt occlusion of the thoracic duct at the ligation site without contrast passage - in 37 patients (92.5%). Among 37 patients with complete TDL, contrast leakage below the ligation site was identified in 15 (41%). Cisterna chyli or thoracic duct cannulation was successful in 38 patients (95%). Overall clinical success of TDE was 62.5% (25/40). Post-procedure day 1 drain output was significantly lower in successful cases (324 mL vs 852 mL; p = 0.0003) and time to drain removal was shorter in the low output group (7.5 vs 14.5 days; p = 0.024). No procedure-related adverse events occurred.

CONCLUSIONS: In patients with persistent chylothorax after TDL, the thoracic duct is typically completely ligated and persistent leaks originate from lymphatic injury below the ligation site. Post-procedure day 1 drain output was associated with treatment response and may help guide timely decisions regarding adjunctive interventions.

来源:Journal of Vascular and Interventional Radiology,查看原文。版权归原作者所有。

引用

  1. Journal of Vascular and Interventional Radiology:Persistent Chylothorax despite Complete Thoracic Duct Ligation: Lymphangiographic Findings and Outcomes of Thoracic Duct Embolization
  2. Park, Kim, Kwon, et al. Persistent chylothorax despite complete thoracic duct ligation: lymphangiographic findings and outcomes of thoracic duct embolization. J Vasc Interv Radiol. 2026. PMID: 42764069. doi:10.1016/j.jvir.2026.109093

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。