光子计数CT虚拟平扫与光谱算法评估肝脂肪的对照研究
本研究回顾性纳入42例行腹部光子计数CT动脉期及门静脉期扫描并接受MRI化学位移成像的患者,以MRI脂肪分数为参考标准。比较VNC HU公式法和光谱后处理算法法的肝脂肪定量结果,显示两种CT方法与MRI仅呈中等相关,且不同方法间误差较大。
要点
- 低肝脂肪人群中,CT各定量方法与MRI一致性有限,报告时不宜直接等值换算
- 动脉期光谱后处理算法(SPP-FF)平均绝对误差最低,可优先用于常规报告
- VNC HU公式法在门静脉期误差最大,阅片时应警惕低估或高估肝脂肪
核心结论
- 在低肝脂肪队列中,PCD-CT的VNC HU公式法与光谱后处理算法定量结果与MRI脂肪分数仅呈中等相关,一致性差异较大
研究设计与样本
- 回顾性研究,纳入42例患者,平均年龄66.9±11.4岁,50%为男性
- 研究对象为2022年2月至2024年5月间行腹部PCD-CT动脉期及门静脉期扫描并接受腹部多参数MRI化学位移成像的患者
- 排除无动脉期图像或存在慢性/急性肝病者,以MRI脂肪分数为参考标准
关键影像表现/征象
- CT两种定量方法在动脉期与门静脉期均可见肝脂肪测量值与MRI脂肪分数存在系统性差异
- HU-FF与SPP-FF两种CT方法内部一致性高,提示各自方法重复性良好但准确性受限
诊断标准与关键数值
- SPP-FF动脉期平均绝对误差最低,为3.30%
- HU-FF门静脉期平均绝对误差最高,为4.82%
- 中位MRI脂肪分数为1.49%,四分位距为0.72%-4.57%
- HU-FF与SPP-FF之间相关系数r为0.72-0.80,方法内部一致性r为0.93-0.94
临床应用与阅片要点
- 在低肝脂肪患者中解读CT肝脂肪定量结果时,应同时注明所用重建方式与扫描期相
- 动脉期光谱后处理算法误差最小,适合作为日常CT肝脂肪筛查的首选定量方法
- VNC HU公式法在门静脉期误差较大,不推荐单独用于轻度脂肪肝的精确分级
局限性
- 回顾性单中心研究,样本量仅42例,且以低肝脂肪人群为主
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To evaluate the agreement of different liver fat quantification methods using Photon-Counting-Detector (PCD)-CT via virtual non-contrast (VNC) reconstructions and dedicated spectral post-processing algorithms, with MRI-derived fat fractions (FF) serving as the reference standard.
MATERIALS AND METHODS: This retrospective study included consecutive patients who underwent abdominal PCD-CT in arterial (art) and portal-venous (pv) phases and abdominal multiparametric MRI with chemical shift imaging between February 2022 and May 2024. Patients were excluded if no arterial phase was available or if chronic or acute liver disease was present. Liver FF was quantified using two methods in both contrast phases: via Hounsfield units from VNC images using an established formula (HU-FF), and directly using a spectral post-processing algorithm (SPP-FF). These were compared among themselves and to MRI-FF using Pearson's correlation and mean absolute error (MAE).
RESULTS: The final cohort included 42 patients (mean age, 66.9 ± 11.4 years; 50% male). Median MRI-FF was 1.49% (Interquartile Range [IQR], 0.72%-4.57%). HU-FF and SPP-FF showed moderate correlation with MRI-FF (r = 0.40-0.71, P < .05). Correlation between HU-FF and SPP-FF was high (r = 0.72-0.80), with excellent intra-method agreement (HU-FF: r = 0.94; SPP-FF: r = 0.93). MAE was lowest for SPP-FF-art (3.30%) and highest for HU-FF-pv (4.82%).
CONCLUSION: PCD-CT offers several methods for liver fat quantification, yet, in a cohort with low liver fat, agreement with MRI varied considerably.
引用
- Klemm, Russe, Reisert, et al. Agreement of VNC and Spectral Photon-Counting CT in the Assessment of Normal to Minimal Hepatic Fat in Comparison with MRI. Acad Radiol. 2026. PMID: 41558952. doi:10.1016/j.acra.2026.01.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。