深度学习辅助对比增强乳腺X线诊断的回顾性多阅片者评估
本研究回顾性纳入150例对比增强乳腺X线检查,由5位放射科医生分两次、间隔至少4周分别无辅助与有深度学习辅助下独立阅片。结果显示多数医生病灶水平诊断效能改善,乳腺水平未见提升,1位医生阅片时间减少31%。
要点
- 该工具主要提升病灶水平诊断效能,乳腺水平未见改善,报告时仍需结合双乳整体判断
- 辅助阅读可减少假阳性结果,在89%敏感度下平均减少11.4%,有助于减少不必要召回
- 工具为单视图分析,阅片时应注意其可能遗漏对侧或不同视图病灶
核心结论
- 深度学习辅助工具在对比增强乳腺X线中与病灶水平诊断效能改善和假阳性减少相关,但乳腺水平无改善
研究设计与样本
- 回顾性单中心研究,150例对比增强乳腺X线检查,5位放射科医生参与
- 每位病例分两次阅读,先无辅助、后有辅助,间隔至少4周洗脱期
- 采用自由响应ROC分析、曲线下面积和假阳性率评估病灶及乳腺水平诊断效能
- 记录1位医生阅读时间作为探索性指标
关键影像表现/征象
- 病灶水平自由响应曲线下面积平均增加0.030±0.018
- 在89%敏感度下,所有医生假阳性平均减少11.4%±24%
- 乳腺水平诊断效能未见改善
诊断标准与关键数值
- 在89%敏感度水平下评估假阳性变化,所有医生假阳性平均减少11.4%±24%
- 病灶水平自由响应曲线下面积平均增加0.030±0.018
临床应用与阅片要点
- 深度学习辅助工具可用于对比增强乳腺X线阅片,有助于提升病灶水平检测并减少假阳性
- 该工具仅做单视图分析,报告时需注意其对乳腺整体诊断的价值有限
- 初步数据显示辅助阅读可能缩短阅片时间,提示有流程优化潜力
局限性
- 回顾性单中心研究,样本量150例,阅读时间仅记录1位医生属于探索性分析
- 工具为单视图分析且数据集特征可能解释乳腺水平无改善
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the clinical impact of a deep-learning-based computer-aided diagnostic tool applied to contrast-enhanced mammography on radiologists' diagnostic accuracy and reading efficiency.
METHODS: In this retrospective single-centre study, 150 contrast-enhanced mammography examinations were interpreted by five radiologists. Each case was read and annotated twice in two sequential sessions: first without assistance and then with the computer-aided diagnostic tool, with a minimum 4-week washout period. Diagnostic performance was assessed at lesion and breast levels using free-response receiver operating characteristic analysis, area under the curve, and false-positive rate. Reading time for one radiologist was recorded as an exploratory measure.
RESULTS: The computer-aided diagnostic tool was associated with improved lesion-level performance for most radiologists, with a mean increase in the area under the free-response curve of 0.030 ± 0.018. At 89% sensitivity, false-positive findings decreased by an average of 11.4% ± 24% across all radiologists. No improvement was observed at the breast level, possibly related to the tool's single-view analysis and dataset characteristics. An exploratory analysis showed a 31% reduction in reading time for one radiologist.
CONCLUSION: Integration of a deep learning-based computer-aided diagnostic tool into contrast-enhanced mammography was associated with improved lesion-level diagnostic performance and reduced false-positive findings, without measurable improvement at the breast level.
ADVANCES IN KNOWLEDGE: To our knowledge, this study provides one of the early clinical evaluations of a deep learning-based computer-aided diagnostic tool for contrast-enhanced mammography, suggesting potential improvements in lesion-level diagnostic performance and workflow efficiency while highlighting current limitations at the breast level.
引用
- Moustafa, Jailin, Vancamberg, et al. Retrospective multi-reader evaluation of a Deep-Learning-based cancer detection model in Contrast-Enhanced Mammography. Br J Radiol. 2026. PMID: 42898008. doi:10.1093/bjr/tqag252
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。