急性卒中头颅CT:深度学习重建与ASIR-V比较
回顾性纳入102例急性卒中症状24小时内行头颅平扫CT的成人患者,比较三种强度深度学习重建(DLR-L/M/H)与ASIR-V。DLR-H在多数区域SNR、CNR最高,后颅窝伪影指数显著降低;DLR-M在伪影减少与纹理偏好间取得最佳平衡。诊断信心与ASPECTS在技术间无显著差异。
要点
- DLR-M兼顾伪影减少与纹理偏好,适合日常急性卒中头颅CT重建
- DLR-H噪声最低、SNR/CNR最高,但纹理评分低于ASIR-V
- 各重建方式间诊断信心和ASPECTS无显著差异
核心结论
- DLR相比ASIR-V可改善图像质量并减少伪影
- 中等强度去噪(DLR-M)在伪影减少与纹理偏好间提供最佳平衡
研究设计与样本
- 回顾性研究,102例连续成人患者,平均年龄68.65岁,卒中症状发作24小时内行头颅平扫CT
- 两名设盲放射科医生对噪声感知、灰白质分辨、图像纹理、诊断信心和射束硬化伪影进行5分Likert量表评分
- 定量指标包括SNR、CNR、后颅窝伪影指数(PFAI)和颅板下伪影指数(SAI),并记录ASPECTS
- 定性数据采用Friedman检验及事后Wilcoxon符号秩检验(Bonferroni校正),定量数据采用配对t检验(Benjamini-Hochberg校正)
关键影像表现/征象
- DLR-L和DLR-M灰白质分辨评分显著高于ASIR-V(p<0.05)
- DLR-H显示最低噪声感知,纹理评分低于ASIR-V(p<0.05)
- DLR-H在多数区域SNR和CNR最高,深部核团效应量d=0.934,小脑d=0.917
诊断标准与关键数值
- DLR-H在多数区域SNR和CNR最高,深部核团d=0.934,小脑d=0.917
- 所有DLR去噪强度均显著降低PFAI;DLR-M和DLR-H的SAI显著降低
- ASIR-V与各DLR强度间诊断信心和ASPECTS无显著差异
- DLR-H纹理评分低于ASIR-V(p<0.05)
临床应用与阅片要点
- 急性卒中头颅平扫CT可优先选择DLR-M重建,以平衡伪影抑制与纹理自然度
- 评估后颅窝结构时DLR各级强度均有助于减少伪影
- 重建方式更换不影响ASPECTS评分和诊断信心
局限性
- 单中心回顾性研究设计
- 研究纳入样本为连续患者,缺乏与最终临床结局的关联分析
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare deep learning reconstruction (DLR) at three denoising strengths (Low, Medium, High) with adaptive statistical iterative reconstruction (ASIR-V) for non-contrast head CT (NCCT) in adult patients presenting with acute stroke symptoms. METHODS: In this retrospective study, 102 consecutive patients (mean age, 68.65 years) underwent NCCT within 24 h of stroke symptom onset between December 2024 and April 2025. Raw data were reconstructed using ASIR-V and DLR-L, DLR-M, and DLR-H. Two blinded radiologists assessed perceived noise, gray–white matter differentiation (supratentorial, deep, infratentorial), image texture, diagnostic confidence, and beam-hardening artifacts on 5-point Likert scales. Quantitative metrics included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), posterior fossa artifact index (PFAI), and subcalvarial artifact index (SAI). Alberta Stroke Program Early CT Scores (ASPECTS) were recorded. Qualitative data was analysed using Friedman test with post hoc Wilcoxon signed rank tests (Bonferroni corrected) and quantitative data was analyzed using paired t-tests (Benjamini–Hochberg corrected). RESULTS: DLR-L and DLR-M achieved significantly higher gray–white matter differentiation scores than ASIR-V on pairwise comparisons (p < 0.05). DLR-H demonstrated the lowest perceived noise and lower texture ratings than ASIR-V (p < 0.05). DLR-H had the highest SNR and CNR in most regions, with large effect sizes in the deep nuclei (d = 0.934) and cerebellum (d = 0.917). All DLR strengths significantly reduced PFAI; SAI was significantly lower with DLR-M and DLR-H. Diagnostic confidence, and ASPECTS did not differ significantly between these techniques. CONCLUSION: DLR improves image quality and decreases artifacts compared with ASIR-V. Medium denoising strength (DLR-M) provides an optimal balance of artifact reduction and texture preference.
引用
- Sahu, Anderson, Nair, et al. Comparison of deep learning reconstruction and adaptive statistical iterative reconstruction for head CT in acute stroke. Neuroradiology. 2026. PMID: 41549105. doi:10.1007/s00234-025-03898-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。