双能CT Rho/Z成像与电影渲染诊断跟腱断裂的前瞻性多阅片者研究
本研究前瞻性纳入117例疑似跟腱断裂患者,以MRI及手术所见为参考标准,由3名独立阅片者在灰阶CT、DECT Rho/Z和电影渲染三种模式下判读。结果显示DECT Rho/Z与电影渲染对断裂检出的AUC均大于0.90,显著优于灰阶CT,且对断裂位置和间距的测量与参考标准高度一致。
要点
- DECT Rho/Z与电影渲染对跟腱断裂检出AUC均>0.90,优于灰阶CT
- DECT Rho/Z对撕脱骨折和腱内钙化具有良好敏感度与特异度
- 对部分撕裂,DECT与电影渲染准确率达99.1%(116/117)
核心结论
- DECT Rho/Z与电影渲染对跟腱断裂的诊断性能显著优于灰阶CT,以MRI及手术所见为参考标准时AUC均大于0.90
- 在复杂或非典型撕裂(部分撕裂、撕脱骨折、腱内钙化)中,DECT Rho/Z与电影渲染可提供互补的诊断价值
研究设计与样本
- 前瞻性研究,纳入2024年1月至9月连续117例患者,中位年龄40岁(IQR 32.8–44.0,范围17–62岁),共分析194个DECT/CR数据集(77例双侧154个,40例单侧40个)
- 以MRI作为断裂诊断及定量测量(位置与间距)的参考标准,复杂/非典型撕裂以手术所见为参考标准
- 3名独立阅片者在灰阶CT、DECT Rho/Z和电影渲染三个模式下盲法判读,确定断裂存在、位置及间距
- 通过ROC分析确定Rho/Z诊断阈值,计算AUC、敏感度、特异度、准确率、PPV/NPV
关键影像表现/征象
- DECT Rho/Z与电影渲染对断裂检出AUC均>0.90,显著优于灰阶CT(均为P<0.001)
- 撕裂肌腱与完整肌腱之间的80 keV、Sn150 keV、Rho及Zeff定量参数差异均有统计学意义(均为P<0.001)
诊断标准与关键数值
- DECT Rho/Z与电影渲染对断裂检出AUC均>0.90,显著优于灰阶CT(均为P<0.001)
- 阅片者共识准确率:DECT为94.9%,电影渲染为91.8%,灰阶CT为66.0%
- 部分撕裂亚组中,DECT与电影渲染准确率达99.1%(116/117)
- 断裂位置与间距的测量与参考标准的一致性为κ>0.80
临床应用与阅片要点
- 当MRI不可用或存在禁忌时,DECT Rho/Z与电影渲染可作为跟腱断裂的有效影像评估手段
- 对疑似撕脱骨折或腱内钙化的复杂病例,DECT Rho/Z可提供优于灰阶CT的诊断信息
- 定量参数(80 keV、Sn150 keV、Rho、Zeff)在撕裂与完整肌腱间差异显著,可用于辅助判断
局限性
- 部分撕裂、撕脱骨折及腱内钙化的亚组分析为探索性,样本量有限
- 单中心研究,结果的普适性有待外部验证
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the diagnostic performance of dual-energy computed tomography (DECT) Rho/Z mapping and cinematic rendering (CR) for detecting Achilles tendon rupture.
MATERIALS AND METHODS: In this prospective study, 117 consecutive patients (median age, 40 years; IQR, 32.8-44.0; range, 17-62) underwent DECT between January and September 2024. MRI served as the reference for rupture diagnosis and quantitative measures (location and gap). For complex/atypical tears (partial tears, avulsion fractures, intratendinous calcifications), operative findings were used as the reference standard. Three independent readers, blinded to the reference, interpreted images in three sessions (grayscale CT, DECT Rho/Z, and CR) to determine rupture presence, location, and gap. Diagnostic metrics (AUC, sensitivity, specificity, accuracy, PPV/NPV) were calculated; Rho/Z cutoffs were derived by ROC analysis.
RESULTS: In total, 194 DECT/CR datasets were analyzed (77 bilateral = 154; 40 unilateral = 40). DECT Rho/Z and CR outperformed grayscale CT for rupture detection with AUCs > 0.90 (all P < 0.001). Consensus reader accuracy was higher for DECT (94.9%) and CR (91.8%) than for grayscale CT (66.0%). In exploratory subgroup analyses, DECT showed favorable sensitivity and specificity for avulsion fractures and calcifications; for partial tears, DECT/CR achieved high accuracy (99.1%, 116/117). Measurements of rupture location and gap showed substantial agreement with the reference (κ > 0.80). Quantitative parameters (80-keV, Sn150-keV, Rho, Zeff) differed significantly between ruptured and intact tendons (all P < 0.001).
CONCLUSION: DECT Rho/Z and CR showed strong diagnostic performance versus grayscale CT using MRI/operative findings as references and may provide complementary value in complex cases.
引用
- Wang, Liu, Zhu, et al. Diagnostic performance of dual-energy Rho/Z CT and cinematic rendering in Achilles tendon rupture: a prospective multi-reader study. Skeletal Radiol. 2026. PMID: 41540275. doi:10.1007/s00256-025-05103-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。