乳腺密度对筛查DBT效能指标的影响:301,400例分析
本研究回顾性分析2013至2019年单中心111,143名女性共301,400次筛查数字乳腺断层合成检查,按BI-RADS第5版评估乳腺密度与筛查效能的关系。结果显示致密乳腺显著降低DBT筛查敏感度,D类敏感度仅61.8%,远低于A类的92.8%。研究强调需在筛查建议中报告并考虑乳腺密度,并探索针对致密乳腺的更有效筛查方案。
要点
- 乳腺极度致密(D类)时DBT筛查敏感度仅61.8%,漏诊风险显著升高。
- 报告乳腺密度类别有助于临床判断筛查阴性结果的可靠性。
- 致密乳腺女性可能需要补充筛查手段以提高癌检出率。
核心结论
- 致密乳腺组织显著降低筛查DBT的敏感度,D类敏感度仅为61.8%,显著低于A类的92.8%。
- D类与A类相比特异度也显著降低(aOR 0.64,p<0.001),但与B类、C类无显著差异。
- 研究强调在筛查建议中报告并考虑乳腺密度,并需进一步研究针对致密乳腺女性的更有效筛查方案。
研究设计与样本
- 回顾性研究,纳入2013至2019年单中心学术医疗机构的301,400次筛查DBT检查,涉及111,143名女性,平均年龄59±11岁。
- 效能指标依据BI-RADS第5版图谱计算,采用广义估计方程的多变量logistic回归分析乳腺密度与筛查效能的关联。
关键影像表现/征象
- 乳腺密度分布:A类几乎全脂肪型占8.8%,B类散在纤维腺体密度占50.5%,C类不均匀致密占36.9%,D类极度致密占3.8%。
- 各密度类别癌检出率(每1000例)分别为A类3.4、B类5.6、C类5.2、D类3.7。
诊断标准与关键数值
- 各密度类别敏感度:A类92.8%、B类90.1%、C类81.0%、D类61.8%。
- 各密度类别特异度:A类96.7%、B类94.4%、C类92.5%、D类93.3%。
- D类敏感度显著低于其他各类,调整后比值比(aOR)为0.19至0.43,p值均<0.01。
- D类特异度显著低于A类(aOR 0.64,p<0.001),但与B类、C类相比无显著差异。
临床应用与阅片要点
- 报告乳腺密度为D类时,应警惕DBT筛查假阴性可能,不能因阴性结果排除疑虑。
- 乳腺密度类别应纳入筛查报告中,为临床补充筛查决策提供依据。
- 对C类和D类致密乳腺,影像医生在阅片时需更加细致排查,关注重叠腺体掩盖的病灶。
局限性
- 本研究为单中心回顾性设计,结果外推需谨慎。
- D类样本占比较低(3.8%),可能影响该组效能指标的稳定性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: As of September 2024, the FDA requires that breast imaging practices inform women about their breast density. This study aimed to evaluate the impact of breast density on the performance metrics of screening digital breast tomosynthesis (DBT) examinations.
MATERIALS AND METHODS: We retrospectively reviewed screening DBT examinations performed from 2013 to 2019 at a single academic medical center. Performance metrics were calculated according to the 5th Edition of the BI-RADS Atlas. Associations between breast density and screening performance were examined using multivariable logistic regression with generalized estimating equations.
RESULTS: The cohort included 111,143 women (mean age, 59 ± 11 years) with 301,400 DBT examinations. Breast density was almost entirely fatty (category A) in 8.8%, scattered areas of fibroglandular density (B) in 50.5%, heterogeneously dense (C) in 36.9%, and extremely dense (D) in 3.8%. Cancer detection rates (CDR, per 1000 exams) were 3.4, 5.6, 5.2, and 3.7 for categories A-D, respectively. Sensitivities were 92.8%, 90.1%, 81.0%, and 61.8%. Specificities were 96.7%, 94.4%, 92.5%, and 93.3%. Category D was associated with significantly lower sensitivity than each of the other categories (adjusted odds ratios [aOR] 0.19-0.43, p<0.01 for all). It was associated with significantly lower specificity than almost entirely fatty tissue (aOR 0.64, p<0.001) but not the other two density categories.
CONCLUSION: Dense breast tissue significantly decreases the sensitivity of screening DBT. These findings highlight the need to report and consider breast density in screening recommendations and necessitate further research on more effective screening regimens for women with dense breast tissue.
引用
- Kniss, Mercaldo, Bahl, et al. Impact of Breast Density on Screening Performance Metrics: An Analysis of 301,400 Screening Digital Breast Tomosynthesis (DBT) Examinations. Acad Radiol. 2026. PMID: 41530029. doi:10.1016/j.acra.2025.12.042
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。