文献速递胸部介入CT

鱼钩形与螺旋形定位丝在CT引导肺结节定位中的比较:对并发症及临床结局的影响

Comparison of fish-hook shaped and spiral shaped wires in CT-guided pulmonary nodule localization: Impact on complications and clinical outcomes.
PubMed 文献 · Eur J Radiol · 2026-01-03

本研究回顾性分析2017年11月至2024年12月154例患者157枚肺结节,比较CT引导下鱼钩形与螺旋形定位丝的结局。两种定位丝技术成功率均为94.9%,严重并发症均少见,但螺旋形轻微并发症率低于鱼钩形(21.8% vs 34.2%)。鱼钩形使用和较长操作时间增加轻微并发症风险。

要点

  • 螺旋形与鱼钩形定位丝技术成功率相当,均为94.9%,均可用于CT引导肺结节定位。
  • 螺旋形轻微并发症率低于鱼钩形(21.8% vs 34.2%),从患者角度可优先考虑螺旋形。
  • 警惕空气栓塞和需引流的气胸等严重并发症,尽量缩短操作时间。

核心结论

  • CT引导肺结节定位中,鱼钩形与螺旋形定位丝技术成功率相当,严重并发症方面安全性相似。
  • 螺旋形定位丝轻微并发症率更低,鱼钩形使用和较长操作时间与轻微并发症风险相关。
  • 从患者角度看,轻微并发症的临床意义也应纳入定位丝选择考量。

研究设计与样本

  • 回顾性研究纳入2017年11月至2024年12月154例患者157枚肺结节,均接受CT引导下定位丝定位。
  • 按定位丝类型分为鱼钩形79次操作和螺旋形78次操作。
  • 收集人口学、病灶、操作、手术详情及病理资料,并以定位后无定位丝脱位定义技术成功。

诊断标准与关键数值

  • 技术成功定义为定位后无定位丝脱位。
  • 鱼钩形与螺旋形技术成功率均为94.9%(95%CI:90.1%-99.8% vs 90%-99.8%),类型无显著差异(OR=1.26,95%CI:0.29-5.53)。
  • 轻微并发症率:鱼钩形34.2%(95%CI:23.7%-44.6%),螺旋形21.8%(95%CI:12.6%-31.0%)。
  • 并发症分级:轻微为无需干预,严重为需要干预;严重并发症包括两例空气栓塞和一例需引流的气胸。
  • 鱼钩形使用(OR=2.36,95%CI:1.11-5.09)和较长操作时间(OR=1.06,95%CI:1.02-1.10)与轻微并发症风险相关。

临床应用与阅片要点

  • 两种定位丝技术成功率相当,日常操作可根据设备熟悉度选择。
  • 螺旋形轻微并发症率较低,从患者角度可优先考虑螺旋形定位丝。
  • 应尽量缩短操作时间以降低轻微并发症风险。
  • 操作中及术后需警惕空气栓塞和需引流的气胸等严重并发症。
  • 两组间病理代表性相似。

局限性

  • 研究为回顾性设计,可能存在选择偏倚。
  • 单中心经验可能限制结果外推。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: In December 2020, our center transitioned from a fish-hook to a spiral wire for CT-guided pulmonary nodule localization. This study compared the effectiveness and safety of both techniques.

METHODS: We retrospectively analyzed 154 consecutive patients with 157 pulmonary nodules who underwent CT-guided wire localization between November 2017 and December 2024. Demographic, lesion, procedural, surgical details, and pathology were collected. Technical success was defined as localization without wire dislodgement. Complications were categorized as minor (no intervention) or major (requiring intervention). Logistic regression identified risk factors for localization success and complications.

RESULTS: Localization was performed using fish-hook wires in 79 and spiral wires in 78 procedures. Technical success rates were comparable (94.9 %, 95 %CI: 90.1 %-99.8 % vs. 94.9 %, 95 %CI: 90 %-99.8 %). Major complications were rare (two air embolisms and one drainage-requiring pneumothorax across all procedures). Minor complication rates were 34.2 % (95 % CI: 23.7 %-44.6 %) for fish-hook wires and 21.8 % (95 % CI: 12.6 %-31.0 %) for spiral wires. Pathological representativeness was similar. Wire type showed no difference in localization success (OR = 1.26, 95 % CI: 0.29-5.53). Fish-hook use (OR 2.36, 95 % CI 1.11-5.09) and longer procedure duration (OR 1.06, 95 % CI 1.02-1.10) were associated with minor complication risk.

CONCLUSION: Fish-hook and spiral shaped wires achieved comparable technical success and safety profile regarding major complications for CT-guided pulmonary nodule localization. However, from a patient perspective the relevance of minor complications should also be considered.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang, Stams, de Jonge, et al. Comparison of fish-hook shaped and spiral shaped wires in CT-guided pulmonary nodule localization: Impact on complications and clinical outcomes. Eur J Radiol. 2026. PMID: 41518715. doi:10.1016/j.ejrad.2026.112656

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。