文献速递神经MR

常规MRI参数识别高级别颅内脑膜瘤的诊断价值

Diagnostic Value of Routine MRI Parameters in Identifying High-Grade Intracranial Meningiomas.
PubMed 文献 · Neuroradiology · 2026-01-10

本回顾性单中心研究纳入282例经手术病理证实的脑膜瘤患者,评估术前常规MRI特征对WHO 2/3级脑膜瘤的预测能力。肿瘤体积≥45 cc、存在囊变、中线移位>3 mm、NADC<1.07为高级别脑膜瘤的独立预测因素。联合模型AUC为0.768,敏感度75.5%,特异度62.8%。

要点

  • 肿瘤体积≥45 cc、存在囊变、中线移位>3 mm提示高级别脑膜瘤可能
  • NADC<1.07是高级别脑膜瘤的独立预测因素,阅片时应关注DWI/ADC
  • 联合模型敏感度75.5%、特异度62.8%,可用于术前风险分层但不能替代病理

核心结论

  • 基于常规MRI形态学与扩散特征的多变量模型可在术前对脑膜瘤进行风险分层,辅助手术决策。
  • 肿瘤体积≥45 cc、存在囊变、中线移位>3 mm、NADC<1.07为WHO 2/3级脑膜瘤的独立预测因素。
  • 联合模型AUC为0.768(95% CI: 0.689-0.847),最佳阈值下敏感度75.5%,特异度62.8%。

研究设计与样本

  • 回顾性单中心研究,纳入2010年至2024年间282例经手术病理证实的脑膜瘤患者,平均年龄58.4±13.4岁,女性176例。
  • 术前MRI评估参数包括肿瘤体积、瘤周水肿、不均匀强化、囊变成分、中线移位及标准化表观扩散系数(NADC)。
  • 采用单变量及多变量logistic回归分析确定高级别脑膜瘤(WHO 2/3级)的独立预测因素,以ROC曲线评估模型效能。

关键影像表现/征象

  • 高级别脑膜瘤与肿瘤体积≥45 cc显著相关(p=0.016)。
  • 高级别脑膜瘤与囊变成分的存在显著相关(p=0.005)。
  • 高级别脑膜瘤与中线移位>3 mm显著相关(p=0.024)。
  • 高级别脑膜瘤与NADC<1.07显著相关(p=0.028)。
  • 282例脑膜瘤中78%为WHO 1级,22%为WHO 2级或3级。

诊断标准与关键数值

  • 联合模型AUC为0.768(95% CI: 0.689-0.847),最佳阈值下敏感度75.5%,特异度62.8%。
  • 独立预测因素阈值为:肿瘤体积≥45 cc、中线移位>3 mm、NADC<1.07。
  • 高级别脑膜瘤定义为WHO分级2级或3级。

临床应用与阅片要点

  • 阅片时对脑膜瘤应常规测量肿瘤体积,≥45 cc提示高级别可能。
  • 发现囊变成分或中线移位>3 mm时应在报告中提示高级别脑膜瘤风险。
  • 应加测NADC,NADC<1.07提示高级别可能,有助于术前手术规划。

局限性

  • 回顾性单中心研究设计,样本来自单一机构。
  • 原文指出需要前瞻性、多中心队列进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate whether preoperative MRI features can accurately predict WHO grade 2/3 meningiomas using routinely available imaging parameters.

MATERIALS AND METHODS: This retrospective single-centre study included 282 patients (mean age 58.4 ± 13.4 years; 176 women) who underwent surgery for histologically confirmed meningiomas between 2010 and 2024. Preoperative MRI was assessed for tumour volume, peritumoral oedema, heterogeneous enhancement, cystic components, midline shift, and normalized apparent diffusion coefficient (NADC). Univariable and multivariable logistic regression analyses identified independent predictors of high-grade meningiomas (WHO grade 2/3). Model performance was evaluated with ROC curve analysis.

RESULTS: Among 282 meningiomas, 78% were WHO grade 1 and 22% were grade 2 or 3. High-grade tumours were significantly associated with tumour volume ≥ 45 cc (p= 0.016), presence of cystic components (p = 0.005), midline shift > 3 mm (p = 0.024), and NADC < 1.07 (p = 0.028). These features remained independently associated with higher grade in the multivariable model. The resulting model achieved an AUC of 0.768 (95% CI: 0.689-0.847), with 75.5% sensitivity and 62.8% specificity at the optimal threshold.

CONCLUSION: We obtained a multivariable MRI-based model combining morphologic and diffusion features that potentially enables preoperative risk stratification of meningiomas and supports surgical decision-making. Further validation in prospective, multicentre cohorts is warranted.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Duarte Gomes, Campos Cardoso, Coutinho, et al. Diagnostic Value of Routine MRI Parameters in Identifying High-Grade Intracranial Meningiomas. Neuroradiology. 2026. PMID: 41518389. doi:10.1007/s00234-025-03892-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。