文献速递骨肌外周血管CT

硝酸甘油增强双能CT对膝骨关节炎关节周围动脉成像

Effect of Nitroglycerin-Enhanced Dual-Energy CT on Imaging Periarticular Arteries in Knee Osteoarthritis: A Prospective Observational Study.
PubMed 文献 · Acad Radiol · 2026-01-06

本研究为前瞻性观察研究,纳入60例膝骨关节炎患者,分为舌下含服硝酸甘油组(n=30)与对照组(n=30)。所有患者行下肢双能CT血管成像并重建40-keV虚拟单能图像。结果显示硝酸甘油显著增大动脉直径、提高小动脉显示率及整体图像质量。

要点

  • 舌下含服硝酸甘油可提高膝骨关节炎患者关节周围小动脉的CTA显示率
  • 40-keV虚拟单能图像联合硝酸甘油对术前血管评估有潜在价值
  • 腘动脉及膝中动脉直径在硝酸甘油后显著增大

核心结论

  • 硝酸甘油联合40-keV虚拟单能双能CT可改善膝骨关节炎患者关节周围动脉显影及图像质量,尤其对小血管显示有潜在优势

研究设计与样本

  • 分为硝酸甘油组(n=30)与对照组(n=30),均行下肢双能CT血管成像
  • 采用双能CT并重建40-keV虚拟单能图像(VMI)
  • 评价指标包括对比噪声比(CNR)、动脉直径、整体图像质量评分及可见关节周围动脉数量

关键影像表现/征象

  • 硝酸甘油组腘动脉直径为5.06 ± 0.92 mm,对照组为5.98 ± 0.84 mm(P < .001)
  • 膝中动脉直径由0.79 ± 0.27 mm增至1.06 ± 0.30 mm(P < .001)
  • 膝下内侧动脉显示率由51.6%提高至78.3%(P < .001)
  • 硝酸甘油组整体图像质量评分为4.77 ± 0.54,对照组为3.83 ± 0.73(P < .001)
  • 硝酸甘油组CNR为77.87 ± 21.89,对照组为50.25 ± 15.27(P = .002)

诊断标准与关键数值

  • 评价采用对比噪声比(CNR)、动脉直径、整体图像质量评分及可见关节周围动脉数量
  • 40-keV虚拟单能图像用于下肢CTA重建

临床应用与阅片要点

  • 膝骨关节炎术前血管评估可考虑舌下含服硝酸甘油联合双能CT血管成像
  • 40-keV虚拟单能图像结合硝酸甘油有助于改善小动脉的显示

局限性

  • 为单中心前瞻性观察研究,样本量为60例
  • 未报告随机化方法及盲法实施情况

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Accurate visualization of periarticular arteries is crucial for vascular evaluation in knee osteoarthritis (KOA), which often entails complex vascular changes. This study aims to assess the impact of dual-energy computed tomography (DECT) combined with sublingual nitroglycerin (NTG) on the imaging quality of computed tomographic angiography (CTA) in KOA patients.

MATERIALS AND METHODS: A prospective observational study was conducted, from January 2024 to October 2024, involving 60 patients with KOA. Participants were divided into two groups: one receiving NTG (n = 30) and a control without NTG (n = 30). Lower-limb CTA was performed using DECT, and 40-keV virtual monochromatic images (VMI) were reconstructed. Evaluation metrics included contrast-to-noise ratio (CNR), arterial diameters, overall image quality, and the number of visible periarticular arteries.

RESULTS: NTG administration significantly increased arterial diameters, with the popliteal artery measuring 5.06 ± 0.92 mm vs 5.98 ± 0.84 mm (P < .001) and the middle genicular artery from 0.79 ± 0.27 mm to 1.06 ± 0.30 mm (P < .001). The visualization rate of smaller arteries improved, notably the medial inferior genicular artery from 51.6% to 78.3% (P < .001). Overall image quality scores and CNR were higher in the NTG group (4.77 ± 0.54 vs 3.83 ± 0.73, P < .001; 77.87 ± 21.89 vs 50.25 ± 15.27, P = .002).

CONCLUSION: Combining sublingual NTG with 40-keV virtual monochromatic DECT enhances arterial visualization and imaging quality, especially for smaller vessels, indicating potential benefits for preoperative vascular evaluation in KOA management.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Wang, Feng, Zhu, et al. Effect of Nitroglycerin-Enhanced Dual-Energy CT on Imaging Periarticular Arteries in Knee Osteoarthritis: A Prospective Observational Study. Acad Radiol. 2026. PMID: 41500857. doi:10.1016/j.acra.2025.12.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。