文献速递骨肌MR

MRI测量胫骨后倾角:解剖轴宜选胫骨结节下方

The Anatomical Axis is Preferably Defined Below the Tibial Tuberosity in Magnetic Resonance Imaging-Based Evaluation of Posterior Tibial Slope.
PubMed 文献 · Acad Radiol · 2026-01-07

本研究纳入103例同一膝关节在一年内接受两次MRI检查且无明显形态学变化的患者,比较在胫骨平台下方与胫骨结节下方定义胫骨解剖轴时测量胫骨后倾角的可靠性。结果显示,胫骨结节下方定义解剖轴的复测一致性更好,观察者内及观察者间一致性也良好。

要点

  • MRI测量胫骨后倾角时,解剖轴定义在胫骨结节下方比平台下方更可靠。
  • 胫骨结节下方定义解剖轴时,内侧及外侧后倾角复测ICC均达0.85以上。
  • 平台下方定义解剖轴在不同扫描间变异性较大,临床随访比较时需谨慎。

核心结论

  • 在胫骨结节下方定义解剖轴可获得更可靠的胫骨后倾角测量,复测一致性更好,且观察者内与观察者间一致性良好。

研究设计与样本

  • 回顾性研究,纳入103例患者,2018至2023年间同一膝关节接受两次独立MRI检查,两次扫描间隔一年内且无明显形态学变化。
  • 定义两种胫骨解剖轴:一种位于胫骨平台下方,另一种位于胫骨结节下方;分别测量内侧与外侧胫骨后倾角。
  • 通过扫描间、观察者内及观察者间一致性评估可靠性,并用Bland-Altman一致性界限分析扫描间变异。

诊断标准与关键数值

  • 解剖轴定义在平台下方时,内侧后倾角扫描间ICC为0.651,外侧后倾角扫描间ICC为0.618。
  • 解剖轴定义在胫骨结节下方时,内侧后倾角扫描间ICC为0.864,外侧后倾角扫描间ICC为0.852。
  • 内侧后倾角95%一致性界限:平台下方轴为-6.8°至6.4°,胫骨结节下方轴为-4.4°至4.8°。
  • 外侧后倾角95%一致性界限:平台下方轴为-6.4°至6.5°,胫骨结节下方轴为-4.6°至4.5°。
  • 两种解剖轴定义下,内侧与外侧后倾角测量的观察者内及观察者间一致性均为良好至优秀。

临床应用与阅片要点

  • 日常MRI测量胫骨后倾角时,优先选择胫骨结节下方作为解剖轴的定位水平,以提高多次扫描间的可重复性。
  • 当需要纵向比较同一患者不同时间点后倾角变化时,应统一采用胫骨结节下方定义解剖轴。

局限性

  • 原文未报告该研究为单中心或多中心设计,也未报告回顾性以外的其他设计特征。
  • 研究仅纳入一年内无显著形态学变化的患者,结论在存在明显形态学改变膝关节中的适用性尚不明确。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Multiple approaches are available for defining the tibial anatomical axis when measuring the posterior tibial slope (PTS) with MRI. This study aims to evaluate the reliability of PTS measurements on MRI when the anatomical axis is defined at different tibial levels.

MATERIALS AND METHODS: This study included 103 patients who underwent two distinct MRI examinations of the same knee between 2018 and 2023, with each pair of scans performed within a one-year interval and without significant morphological changes. Two anatomical axes were defined: one below the tibial plateau and another below the tibial tuberosity. The medial and lateral posterior tibial slopes (MPTS and LPTS) were measured relative to each axis. Reliability was evaluated by assessing inter-scan (test-retest), intra-rater, and inter-rater agreement. Variability between scans was further examined using Bland-Altman limits of agreement (LOA).

RESULTS: Defining the anatomical axis below the tibial plateau resulted in only moderate inter-scan agreement (MPTS: ICC = 0.651; LPTS: ICC = 0.618), whereas defining it below the tibial tuberosity yielded good agreement (MPTS: ICC = 0.864; LPTS: ICC = 0.852). The 95% LOA between scans for MPTS were -6.8° to 6.4° with the plateau-based axis and -4.4° to 4.8° with the tuberosity-based axis, while those for LPTS were -6.4° to 6.5° and -4.6° to 4.5°, respectively. Both definitions of the axis demonstrated good to excellent intra- and inter-rater reliability for MPTS and LPTS measurements.

CONCLUSION: Defining the anatomical axis below the tibial tuberosity yields more reliable PTS measurements, with better inter-scan agreement and good intra- and inter-rater agreement.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Jia, Zhang, Qiang, et al. The Anatomical Axis is Preferably Defined Below the Tibial Tuberosity in Magnetic Resonance Imaging-Based Evaluation of Posterior Tibial Slope. Acad Radiol. 2026. PMID: 41500859. doi:10.1016/j.acra.2025.12.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。