单次屏气胰腺PDFF成像:C-SENSE与深度学习重建加速
该研究对71名肥胖成人(BMI 30.0-39.9 kg/m2,无糖尿病)的104份腹部MRI数据,评估C-SENSE和深度学习辅助重建在单次屏气胰腺质子密度脂肪分数(PDFF)成像中的表现。C-SENSE10与AI重建较C-SENSE6具有高度一致性(R2≥0.99),组内相关系数达0.87-1.00。深度学习重建在保持PDFF准确性的同时降低图像噪声。
要点
- 胰腺PDFF可在16.9秒(R=6)或10.3秒(R=10)单次屏气内完成采集
- 深度学习重建降低R=10加速带来的图像噪声,且不改变PDFF数值
- 全胰腺分割较局部ROI测量的可重复性更高(ICC 0.87-1.00)
核心结论
- 加速CSE成像可实现单次屏气胰腺PDFF量化,具备精确性、可重复性和临床可行性,适用于肥胖及代谢性疾病中胰腺脂肪变性的评估
研究设计与样本
- 前瞻性生活方式干预试验的影像学数据分析,104份腹部MRI数据来自71名成人(58%为女性,年龄18-65岁,BMI 30.0-39.9 kg/m2,无糖尿病)
- 使用3T MRI(Ingenia Elition X,Philips),两个六回波梯度回波序列,体素2×2×3 mm3,TR/TE/回波间隔一致
- 加速因子R=6(16.9秒)和R=10(10.3秒),R=6和R=10使用压缩感知(C-SENSE6、C-SENSE10)重建,R=10额外使用深度学习辅助重建(C-SENSE AI10)
- PDFF测量采用三个区域ROI(头、体、尾)和全胰腺分割
关键影像表现/征象
- C-SENSE6测量的平均胰腺PDFF基线(V1)为15.0 [10.9-23.0]%,一年后(V3)为8.2 [7.1-11.4]%
- 所有重建方法中PDFF范围为3.5-47.6%
- 深度学习辅助重建的PDFF图像较C-SENSE10噪声更低,但PDFF测量值与C-SENSE6的线性关系仍达R2≥0.99
诊断标准与关键数值
- C-SENSE10与C-SENSE AI10对比C-SENSE6的PDFF测量线性关系R2≥0.99
- 全胰腺分析不同方法间组内相关系数(ICC)为0.87-1.00
临床应用与阅片要点
- 报告胰腺PDFF时建议使用全胰腺分割替代局部ROI,以提高可重复性和稳定性
- R=10加速可将扫描时间缩短至10.3秒,适用于屏气困难患者,同时保持与R=6相同的测量精度
局限性
- 样本来自特定肥胖人群(BMI 30.0-39.9 kg/m2,无糖尿病),结果外推至其他人群需谨慎
- 数据来自单一中心、单一3T设备平台
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: With the rising prevalence of obesity and metabolic syndrome, there is an increasing need for noninvasive quantification of pancreatic fat as a marker of metabolic risk. Chemical shift encoding (CSE)-based water-fat separation enables pancreatic proton density fat fraction (PDFF) mapping. This study evaluates techniques for accelerating high-resolution, single-breath-hold PDFF mapping using sparse sampling with compressed sensing with sensitivity encoding (C-SENSE) and a deep learning (DL)-assisted reconstruction algorithm, focusing on reproducibility, precision, and clinical applicability.
METHODS: 104 abdominal MRI datasets were obtained from 71 adults (58 % female; age 18-65 years; body mass index (BMI) 30.0-39.9 kg/m2; without diabetes) enrolled in a lifestyle intervention trial. Imaging was performed at 3 T (Ingenia Elition X, Philips) using two six-echo gradient-echo acquisitions (2 × 2 × 3 mm3, identical TR/TE/echo spacing). Acceleration factors of R = 6 (16.9 s) and R = 10 (10.3 s) were reconstructed using vendor compressed sensing (C-SENSE6, C-SENSE10); the DL-assisted reconstruction (C-SENSE AI10) was applied only to R = 10 to evaluate denoising of higher-acceleration data. PDFF maps were analyzed using three regional regions of interest (ROIs) (head, body, tail) and whole-pancreas segmentation.
RESULTS: A Mean pancreatic PDFF measured with C-SENSE6 was 15.0 [10.9 - 23.0] % at baseline (V1) and 8.2 [7.1 - 11.4] % after one year (V3). Across all reconstructions, PDFF ranged 3.5 - 47.6 %. Strong linearity was observed between C-SENSE10 and C-SENSE AI10 compared with C-SENSE6 (R2 ≥ 0.99). Whole-pancreas analysis showed high reproducibility (intraclass correlation coefficient = 0.87 - 1.00 across methods). The DL-assisted reconstruction reduced map noise compared with conventional C-SENSE10 without affecting PDFF accuracy.
CONCLUSION: Accelerated CSE-based pancreatic PDFF mapping enables precise, reproducible, and clinically feasible single-breath-hold fat quantification. The approach provides a robust tool for evaluating pancreatic steatosis in obesity and metabolic disease research.