文献速递头颈神经MRCT

颈静脉球瘤术前评估颈内动脉侵犯:增强3D BRAVO的应用

Preoperative evaluation of internal carotid artery invasion in glomus jugulare tumors: applicability of contrast-enhanced 3D brain volume imaging.
PubMed 文献 · Neuroradiology · 2026-01-07

本研究回顾性分析21例经手术证实的颈静脉球瘤影像资料,比较增强3D BRAVO、增强FSE T1WI和增强CT对颈内动脉侵犯的评估效能。结果显示增强BRAVO在Fisch C型判断上与手术结果完全一致,优于增强FSE和CT,但与增强CT在颈内动脉包绕和狭窄评估上具有互补价值。

要点

  • 增强BRAVO判断Fisch C型与手术金标准完全一致(κ=1.000)
  • 颈内动脉包绕和狭窄评估增强CT优于BRAVO
  • 增强BRAVO与颞骨增强CT应互补使用评估颈内动脉受累

核心结论

  • 增强BRAVO在Fisch C型判断上与手术金标准完全一致,κ=1.000,P<0.001
  • 增强BRAVO与颞骨增强CT对颈静脉球瘤颈内动脉受累评估具有互补价值,均优于常规增强FSE T1WI

研究设计与样本

  • 回顾性分析21例经手术证实的颈静脉球瘤患者影像资料
  • 纳入颞骨增强BRAVO、增强FSE T1WI和颞骨增强CT三种序列
  • 以术中评估为金标准,按Fisch标准分别进行影像C型判断并比较

关键影像表现/征象

  • 增强BRAVO对Fisch C型判断κ=1.000,优于增强FSE κ=0.561和增强CT κ=0.702
  • 颈内动脉包绕评估中增强CT κ=0.648优于增强BRAVO κ=0.513和增强FSE κ=0.431
  • 颈内动脉狭窄评估中增强CT κ=0.716优于增强BRAVO κ=0.588和增强FSE κ=0.339

诊断标准与关键数值

  • Fisch C型判断:增强BRAVO κ=1.000(P<0.001),增强FSE κ=0.561,增强CT κ=0.702
  • 颈内动脉包绕:增强BRAVO κ=0.513,增强FSE κ=0.431,增强CT κ=0.648
  • 颈内动脉狭窄:增强BRAVO κ=0.588,增强FSE κ=0.339,增强CT κ=0.716

临床应用与阅片要点

  • 增强BRAVO可作为颈静脉球瘤Fisch分型的可靠影像序列
  • 评估颈内动脉管壁受累程度时应结合颞骨增强CT观察
  • 常规增强FSE T1WI对颈内动脉侵犯评估价值有限

局限性

  • 单中心回顾性研究,样本量仅21例

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Accurate preoperative assessment of internal carotid artery (ICA) invasion is crucial in managing glomus jugulare tumors. This study evaluated the efficacy of contrast-enhanced 3D BRAin VOlume (BRAVO) imaging compared to enhanced fast spin-echo (FSE) T1-weighted imaging and enhanced computed tomography (CT).

METHODS: Retrospective analysis was performed on imaging data from surgically confirmed glomus jugulare tumors, including temporal bone enhanced BRAVO, enhanced T1-weighted FSE, and temporal bone enhanced CT sequences. ICA encasement and stenosis by tumor were graded and compared based on intraoperative assessment. According to Fisch criteria, the preoperative image C-type based on BRAVO, FSE and CT were separately and compared with surgical C-type (gold standard).

RESULTS: Among 21 patients, For image Fisch C-type, BRAVO showed excellent agreement with surgical C-type (κ = 1.000, P < 0.001), outperforming enhanced FSE (κ = 0.561) and CT (κ = 0.702). For ICA encasement, BRAVO had moderate agreement (κ = 0.513), slightly better than enhanced FSE (κ = 0.431) but inferior to enhanced CT (κ = 0.648). For ICA stenosis, BRAVO (κ = 0.588) surpassed enhanced FSE (κ = 0.339) but was less accurate than enhanced CT (κ = 0.716).

CONCLUSION: Enhanced BRAVO and temporal bone enhanced CT are complementary for assessing ICA involvement in glomus jugulare tumors, offering superior accuracy over conventional FSE imaging.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Su, Tian, Mao, et al. Preoperative evaluation of internal carotid artery invasion in glomus jugulare tumors: applicability of contrast-enhanced 3D brain volume imaging. Neuroradiology. 2026. PMID: 41498833. doi:10.1007/s00234-025-03886-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。