胎儿下肾上腺动脉多普勒血流参数纵向参考范围
本研究为挪威单中心前瞻性纵向队列研究,纳入低危单胎妊娠146例,于孕19–41周每4周行胎儿下肾上腺动脉多普勒检查,608次检查中542次成功获取血流参数。基于混合线性模型建立PI、PSV、TAmax与EDV的纵向参考范围,并给出个体化条件参考范围计算方法。
要点
- 胎儿下肾上腺动脉PI在孕中期轻微升高,近足月下降。
- PSV孕中期稳定,自孕30周至孕晚期呈上升趋势。
- 该参考范围仅适用于低危单胎妊娠人群的连续测量。
核心结论
- 在低危单胎妊娠中建立了孕19–41周胎儿下肾上腺动脉PI与PSV的纵向参考范围。
- 提供了计算连续测量血流参数个体化条件参考范围的公式及其适用条件。
研究设计与样本
- 前瞻性纵向队列研究,单中心,地点为挪威斯塔万格大学医院。
- 纳入2020年6月至2023年5月常规中孕期筛查的低危单胎妊娠女性146例。
- 受检者自孕19周至41周每4周评估一次,每人完成1–6次检查。
- 采用SlowFlow™能量多普勒显示胎儿下肾上腺动脉,并用脉冲多普勒记录血流速度参数。
关键影像表现/征象
- 胎儿下肾上腺动脉PI在孕中期轻度上升,接近足月时下降。
- 胎儿下肾上腺动脉PSV在孕中期保持稳定,自孕30周起至孕晚期增加。
诊断标准与关键数值
- 608次检查中542次成功测得胎儿下肾上腺动脉血流速度,成功率89%。
- 使用混合线性模型估计PI、PSV、EDV与TAmax的纵向参考范围。
- 下肾上腺动脉定义及血流速度测量技术采用作者既往研究中描述的方法。
临床应用与阅片要点
- 可用于低危单胎妊娠孕19–41周胎儿下肾上腺动脉PI与PSV的连续监测。
- 报告连续测量时可依据原文公式计算个体化条件参考范围。
局限性
- 研究为单中心设计,参考范围向其他人群推广时需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Blood flow to the fetal adrenal arteries is shown to increase during placental dysfunction in animal studies. Reference ranges of fetal adrenal blood flow parameters are needed to explore the diagnostic possibilities of this concept in humans. The aim of this study was to establish longitudinal reference ranges for pulsatility index (PI), peak systolic velocity (PSV), time-averaged maximum velocity (TAmax) and end-diastolic velocity (EDV) of the inferior adrenal artery of human fetuses across the second half of gestation.
METHODS: This was a prospective longitudinal cohort study conducted at Stavanger University Hospital, Stavanger, Norway, of women with a singleton low-risk pregnancy presenting for routine second-trimester screening between June 2020 and May 2023. Participants were examined every 4 weeks, from 19 to 41 weeks' gestation, to establish longitudinal reference ranges for the abovementioned blood velocity parameters, covering the second half of pregnancy. We used the visualization and blood flow velocity measurement techniques, as well as the definition of the inferior adrenal artery, as described in our previous study. Each assessment included ultrasound examination with SlowFlow™ power Doppler to visualize the fetal inferior adrenal artery and pulsed-wave Doppler to record blood velocity parameters in this artery, with one to six assessments per participant over the course of the second half of pregnancy. At each assessment, PSV, EDV and TAmax were measured and the PI was calculated. Mixed linear models were used to estimate the longitudinal reference ranges.
RESULTS: In total, 146 participants were examined and the blood velocity in the fetal inferior adrenal artery was measured successfully in 542/608 examinations, yielding a success rate of 89%. Based on this dataset, we constructed longitudinal reference ranges for PI and PSV, as well as for EDV and TAmax, of the fetal inferior adrenal artery throughout the second half of gestation. The PI of the fetal inferior adrenal artery increased slightly throughout the second trimester and declined towards term. The PSV of the fetal inferior adrenal artery was stable throughout the second trimester, but increased from 30 weeks' gestation until the end of the third trimester.
CONCLUSION: We present longitudinal reference ranges for PI and PSV of the fetal inferior adrenal artery in low-risk singleton pregnancies across the second half of pregnancy. Additionally, we provide terms, including formulae and the conditions under which they apply, for calculating individualized conditional reference ranges for serial measurements of blood velocity parameters. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Bergøy, Dalen, Kiserud, et al. Longitudinal reference ranges for Doppler blood velocity parameters of inferior adrenal artery in the human fetus. Ultrasound Obstet Gynecol. 2026. PMID: 41489412. doi:10.1002/uog.70150
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。