实时AI乳腺超声在低度可疑4A病灶中的活检决策价值

Defining the Clinical Indication for Real-Time Artificial Intelligence-Assisted Ultrasound in Breast Lesions with Low Suspicion of Malignancy.
PubMed 文献 · J Ultrasound Med · 2026-10-18

回顾性分析641例连续乳腺超声BI-RADS 4A病灶,以病理为金标准,评估实时AI超声系统CadAI-B®联合乳腺X线分层能否安全减少不必要的活检。单独AI策略在AI分级≤2或≤3时活检延迟分别漏诊30.8%和38.5%恶性肿瘤,以导管原位癌为主。在无非可疑乳腺X线发现的前提下,AI BI-RADS 1-3病灶中未观察到恶性肿瘤,该序贯策略可减少43.5%活检且敏感度保持100.0%。

要点

  • 单独用实时AI乳腺超声对4A病灶降级并延迟活检会漏诊较多导管原位癌
  • 无非可疑乳腺X线发现且AI降为BI-RADS 1-3者可能无需立即活检
  • 阅片时优先关注AI仍为BI-RADS 4A或伴可疑乳腺X线发现的病灶

核心结论

  • 单独使用实时AI乳腺超声不能安全支持对超声BI-RADS 4A病灶延迟活检,因为在AI BI-RADS≤2和≤3时分别漏诊30.8%和38.5%的恶性肿瘤。
  • 在排除了可疑乳腺X线发现后,AI重新分为BI-RADS 1-3的病灶中未观察到恶性肿瘤。
  • 对AI BI-RADS≤3且乳腺X线无可疑发现的病灶延迟活检,可减少43.5%活检,同时敏感度保持100.0%。

研究设计与样本

  • 单中心回顾性分析,纳入641例连续超声BI-RADS 4A病灶,均接受真空辅助乳腺活检。
  • 活检前使用实时AI超声系统CadAI-B®对病灶重新评估,乳腺X线发现根据正式报告分为可疑或非可疑。
  • 以最终病理为参考标准,评估7种预设活检决策策略,主要结局包括活检减少率、漏诊癌、敏感度、特异度、阳性预测值、阴性预测值和准确度。

关键影像表现/征象

  • AI将641例病灶中的289例重新分为BI-RADS 1-3类。
  • 最终病理识别出26例恶性肿瘤,其中14例导管原位癌、11例浸润性导管癌和1例大汗腺癌。
  • 无非可疑乳腺X线发现且AI BI-RADS 1-3的病灶中,恶性肿瘤为0例。

诊断标准与关键数值

  • 641例超声BI-RADS 4A病灶中,26例恶性,恶性率为4.1%。
  • AI BI-RADS≤2时延迟活检漏诊8/26例恶性肿瘤,漏诊率为30.8%。
  • AI BI-RADS≤3时延迟活检漏诊10/26例恶性肿瘤,漏诊率为38.5%。
  • 对AI BI-RADS≤3且乳腺X线无可疑病灶者延迟活检,敏感度为100.0%(95% CI, 87.1-100.0%),特异度为45.4%(95% CI, 41.4-49.4%)。
  • 该联合策略减少活检43.5%,即279/641例。

临床应用与阅片要点

  • 实时AI乳腺超声对4A病灶的降级结果不应单独作为延迟活检依据,尤其是AI降级后仍需警惕导管原位癌。
  • 将AI分级与乳腺X线报告结合可筛选出低风险亚组,减少不必要活检且不降低检出率。
  • 在临床推广前需前瞻性多中心验证,现阶段不建议仅凭AI对4A病灶做降级处理。

局限性

  • 该研究为单中心回顾性设计,可能存在选择偏倚。
  • 作者指出需前瞻性多中心验证后方可临床实施。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate whether real-time artificial intelligence (AI) breast ultrasound (US) can identify a subgroup of breast imaging reporting and data system (BI-RADS) category 4A lesions without suspicious mammographic (MMG) findings in whom unnecessary biopsy may be safely avoided.

METHODS: This retrospective analysis of single-center biopsy registry included 641 consecutive US BI-RADS 4A lesions that underwent vacuum-assisted breast biopsy. Before conducting biopsy, the lesions were reassessed using a real-time AI US system (CadAI-B®), and MMG findings were classified as suspicious or non-suspicious based on formal reports. Seven prespecified biopsy-decision strategies were evaluated, including 3 AI-only strategies, 3 mammography-gated AI strategies, and the current standard strategy of biopsy all BI-RADS 4A lesions. The primary outcomes were biopsy reduction rate, missed cancers, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, with final pathology as the reference standard.

RESULTS: Among 641 cases of US BI-RADS 4A lesions, 26 cases of malignancies (4.1%) were identified, including 14 cases of ductal carcinoma in situ (DCIS), 11 cases of invasive ductal carcinomas, and 1 case of apocrine carcinoma. AI reassigned 289 cases of lesions (45.1%) to BI-RADS categories 1-3. AI-only biopsy-deferral strategies missed 30.8% and 38.5% of malignancies when biopsy was deferred for AI BI-RADS ≤2 and ≤3 lesions, respectively, with DCIS accounting for most missed cancers. In contrast, among lesions without suspicious MMG findings, no malignancies were observed in AI BI-RADS 1-3 lesions. The sequential strategy of deferring biopsy only for lesions with AI BI-RADS ≤3 and non-suspicious MMG findings reduced biopsies by 43.5% (279/641) while maintaining 100.0% sensitivity (95% CI, 87.1-100.0%) and increasing specificity to 45.4% (95% CI, 41.4-49.4%).

CONCLUSION: Real-time AI breast US alone could not safely support biopsy deferral in US BI-RADS 4A lesions. However, after suspicious MMG findings had been excluded, AI identified a low-risk subgroup in whom unnecessary biopsy could be substantially reduced without compromising cancer detection. These findings suggest that the clinical utility of real-time AI breast US lies in patients without suspicious MMG findings. Prospective multicenter validation is warranted before clinical implementation.

来源:J Ultrasound Med,查看原文。版权归原作者所有。