文献速递头颈外周血管CT

光子计数CT与传统能量积分CT检测颈动脉体比较

Carotid Body Detection Rate and Size on Photon-Counting Versus Energy-Integrating Detector CT.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-10-19

本研究回顾性纳入48例成人患者,均接受头颈CTA光子计数CT(PCCT)与能量积分探测器CT(EIDCT)动静脉期扫描。结果显示PCCT颈动脉体检出率高于EIDCT,尤其是右侧,但PCCT测得颈动脉体体积更小,右侧大于左侧。

要点

  • PCCT比EIDCT更易检测到颈动脉体,尤其右侧动静脉期均达96%
  • PCCT测得颈动脉体体积比EIDCT平均小2.7 mm³,报告中需注意设备差异
  • 右侧颈动脉体普遍大于左侧,造影期相对体积无明显影响

核心结论

  • PCCT相比EIDCT提高颈动脉体检出率,但测量体积更小。
  • 右侧颈动脉体体积大于左侧,造影期影响轻微。
  • 调整年龄、性别和高血压后设备与侧别效应仍然显著。

研究设计与样本

  • 回顾性研究,单中心48例成人患者,均行头颈CTA PCCT与EIDCT动静脉期扫描。
  • 采用混合效应logistic回归分析检出率,线性混合效应模型分析体积,敏感性分析校正年龄、性别、高血压。

关键影像表现/征象

  • PCCT右侧颈动脉体检出动静脉期均为96%,EIDCT分别为77%和82%。
  • PCCT左侧颈动脉体检出动静脉期分别为85%和83%,EIDCT分别为81%和82%。
  • 右侧颈动脉体体积在各设备上均大于左侧。

临床应用与阅片要点

  • 阅片时注意PCCT颈动脉体检出率高于EIDCT,不要将PCCT显示的小体积正常结构误判为异常。
  • 左右侧颈动脉体大小不对称是正常表现,右侧通常更大。
  • 动静脉期对颈动脉体大小测量影响很小,临床评估无需强调某一期相。

局限性

  • 本研究为单中心回顾性设计。
  • 样本量为48例,成人患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the carotid body (CB) detection rate and size measured on photon-counting CT (PCCT) versus energy-integrating detector CT (EIDCT), and to evaluate the effects of laterality and contrast phase.

METHODS: This retrospective study was conducted at a single institution on 48 adult patients who underwent head and neck CTA on both PCCT and EIDCT on arterial and venous phase imaging. CB detection was analyzed as a binary outcome using a mixed-effects logistic regression model with modality, phase, side, and modality-by-phase interaction as fixed effects, and patient as a random effect. CB size was analyzed using a linear mixed-effects model with the same fixed effects and patient as a random effect. Sensitivity analysis for CB size adjusted for age, sex, and hypertension.

RESULTS: CB detection rates were higher on PCCT than on EIDCT, particularly on the right side (arterial, 96% vs 77%; venous, 96% vs 82%), and slightly higher on the left side (arterial, 85% vs 81%; venous, 83% vs 82%). In mixed-effects logistic regression, PCCT was associated with higher odds of CB detection than EIDCT (OR, 3.97; P = .009). CB size was significantly smaller when measured on PCCT than on EIDCT (estimated difference, -2.7 mm³; P = .01). The right CB was larger than the left across modalities (estimated difference, +4.7 mm³; P < .001). There was no significant difference in CB measurements between arterial and venous phases (P = .53), and no significant modality-by-phase interaction (P = .98). In sensitivity analysis, the modality and side effects remained significant after adjustment for age, sex, and hypertension.

CONCLUSION: PCCT improves CB detection compared with EIDCT but yields smaller CB measurements. CB size is greater on the right than on the left, with minimal effect of contrast phase. These findings remained robust after adjustment for age, sex, and hypertension.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Unger, Arizono, Buch, et al. Carotid Body Detection Rate and Size on Photon-Counting Versus Energy-Integrating Detector CT. AJNR Am J Neuroradiol. 2026. PMID: 42896919. doi:10.3174/ajnr.A9684

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。